Comparison of 51Cr-EDTA and 99mTc-DTPA for glomerular filtration rate measurement

被引:18
|
作者
Vidal-Petiot, Emmanuelle [1 ,2 ,3 ]
Courbebaisse, Marie [1 ,4 ,5 ]
Livrozet, Marine [6 ,7 ]
Correge, Gwenaelle [8 ]
Rusu, Timofei [8 ]
Montravers, Francoise [6 ,8 ]
Baron, Stephanie [1 ,4 ,9 ]
Dupont, Lea [10 ]
Balouzet, Clara [10 ]
Smadja, Corinne [10 ]
Leygnac, Sebastien [11 ,12 ]
Pariscoat, Guillaume [11 ,13 ]
Rose, Jimmy [13 ]
Rouzet, Francois [1 ,11 ,14 ]
Houillier, Pascal [1 ,4 ,9 ]
Haymann, Jean-Philippe [6 ,7 ]
Flamant, Martin [1 ,2 ,3 ]
机构
[1] Univ Paris, Paris, France
[2] Hop Bichat Claude Bernard, AP HP, Physiol Dept, 46 Rue Henri Huchard, F-75018 Paris, France
[3] Ctr Res Inflammat, INSERM, U1149, Paris, France
[4] Hop Europeen Georges Pompidou, AP HP, Physiol Dept, F-75015 Paris, France
[5] CNRS, Inst Necker Enfants Malad, INSERM, U1151,UMR8253, Paris, France
[6] Sorbonne Univ, Paris, France
[7] Hop Tenon, AP HP, Physiol Dept, F-75020 Paris, France
[8] Hop Tenon, AP HP, Dept Nucl Med, F-75020 Paris, France
[9] Univ Paris, Ctr Rech Cordeliers, INSERM, F-75006 Paris, France
[10] Hop Europeen Georges Pompidou, AP HP, Radiopharm Unit, F-75015 Paris, France
[11] Hop Bichat Claude Bernard, AP HP, Dept Nucl Med, F-75018 Paris, France
[12] Hop Bichat Claude Bernard, AP HP, Dept Radiol, F-75018 Paris, France
[13] Hop Bichat Claude Bernard, AP HP, Radiopharm Unit, F-75018 Paris, France
[14] INSERM, U1148, Lab Vasc Translat Res, F-75018 Paris, France
关键词
Glomerular filtration rate measurement; (51)cr-EDTA; (99m)tc-DTPA; Radio-labelled tracers; Plasma clearance; Renal clearance;
D O I
10.1007/s40620-020-00932-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose The production of Cr-51-labelled ethylenediaminetetraacetic acid (Cr-51-EDTA), a validated and widely used radio-isotopic tracer for glomerular filtration rate (GFR) measurement in Europe, was recently halted by the manufacturer. Technetium-99m-diethylenetriaminepentaacetic acid (Tc-99m-DTPA) clearance has so far mostly been restricted to assessment of separate renal function by scintigraphy, but scarcely used and validated for GFR measurement. We compared the performances of Cr-51-EDTA and Tc-99m-DTPA for GFR and extracellular fluid measurement. Methods In a multi-centre prospective study, Cr-51-EDTA and Tc-99m-DTPA were simultaneously injected into 88 patients, and their urinary and plasma clearances, as well as their volumes of distribution, were measured during seven 30-min periods after a 90-min equilibrium time. Results Mean age was 52.2 +/- 14.5 years, 59% were men. Urinary clearances of Cr-51-EDTA and Tc-99m-DTPA were 64.1 +/- 27.6 and 66.1 +/- 28.0 mL/min, respectively, with a mean bias of 2.00 +/- 2.25 mL/min, an accuracy within 10% of 95% [95% CI 91-99], and a coefficient of determination (R-2) of 0.994. Plasma clearances of Cr-51-EDTA and Tc-99m-DTPA were 66.1 +/- 25.8 and 68.1 +/- 26.6 mL/min, respectively, with a mean bias of 1.96 +/- 3.32 mL/min, an accuracy within 10% of 91% [95% CI 85-97] and a R-2 of 0.985. Distribution volumes were 17.3 +/- 4.6 L for Cr-51-EDTA and 16.6 +/- 4.6 L for Tc-99m-DTPA (R-2 0.930). Conclusion The accuracy and precision of Tc-99m-DTPA clearance, compared to Cr-51-EDTA clearance, was excellent for both urinary and plasma clearance methods, despite an approximate 2 mL/min overestimation, showing that the tracer is a reliable alternative to Cr-51-EDTA for GFR measurement. [GRAPHICS] .
引用
收藏
页码:729 / 737
页数:9
相关论文
共 50 条
  • [31] An evaluation of the body surface area correction for 51Cr-EDTA measurements of glomerular filtration rate
    Blake, GM
    Grewal, GS
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (05) : 447 - 451
  • [32] Measuring glomerular filtration rate from plasma clearance of 51Cr-EDTA: quality assurance
    Rehling, Michael
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (04) : 713 - 714
  • [33] Determining the Minimum Number of Blood Samples for Glomerular Filtration Rate Determination with 51Cr-EDTA
    Rannou, M.
    Dekyndt, B.
    Legrand, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S438 - S438
  • [34] Study of the evolution of glomerular filtration rate (GFR) in kidney transplant using 51Cr-EDTA
    Martinez Montalban, E.
    De Gracia Gonzalez, C.
    Martin Curto, L.
    Martinez de Miguel, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S407 - S407
  • [35] Validation of the Abbreviated form of the MDRD Equation in patients referred for Glomerular Filtration rate (GFR) measurement by 51Cr-EDTA
    Arsos, G.
    Moralidis, E.
    Karavida, N.
    Boussios, N.
    Chatzikyrkoy, C.
    Papagianni, A.
    Karakatsanis, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S113 - S113
  • [36] Assessment of glomerular filtration rate in diabetic nephropathy using the plasma clearance of 51Cr-EDTA
    Hansen, HP
    Rossing, P
    Mathiesen, ER
    Hommel, E
    Smidt, UM
    Parving, HH
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1998, 58 (05): : 405 - 413
  • [37] Time to complete mixing for the measurement of glomerular filtration rate from single bolus plasma 51Cr-EDTA clearance
    Bird, NJ
    Henderson, BL
    Lui, D
    Peters, M
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (04) : 393 - 398
  • [38] Variability of estimated glomerular filtration rate and 99mTc-DTPA glomerular filtration rate: implications for a single time-point sampling regime
    Bonney, Lara M.
    McGowan, Daniel R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (05) : 351 - 357
  • [39] COMPARISON OF CR-51 EDTA CLEARANCE WITH FORMULAS IN THE MEASUREMENT OF GLOMERULAR-FILTRATION RATE
    SINTON, TJ
    DELEACY, EA
    COWLEY, DM
    PATHOLOGY, 1986, 18 (04) : 445 - 447
  • [40] 99mTc-DTPA volume of distribution, half-life and glomerular filtration rate in normal adults
    Holness, Jennifer L.
    Fleming, John S.
    Malaroda, Alessandra L.
    Warwick, James M.
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (10) : 1005 - 1014