Comparison of 51Cr-EDTA and 99mTc-DTPA for glomerular filtration rate measurement

被引:18
|
作者
Vidal-Petiot, Emmanuelle [1 ,2 ,3 ]
Courbebaisse, Marie [1 ,4 ,5 ]
Livrozet, Marine [6 ,7 ]
Correge, Gwenaelle [8 ]
Rusu, Timofei [8 ]
Montravers, Francoise [6 ,8 ]
Baron, Stephanie [1 ,4 ,9 ]
Dupont, Lea [10 ]
Balouzet, Clara [10 ]
Smadja, Corinne [10 ]
Leygnac, Sebastien [11 ,12 ]
Pariscoat, Guillaume [11 ,13 ]
Rose, Jimmy [13 ]
Rouzet, Francois [1 ,11 ,14 ]
Houillier, Pascal [1 ,4 ,9 ]
Haymann, Jean-Philippe [6 ,7 ]
Flamant, Martin [1 ,2 ,3 ]
机构
[1] Univ Paris, Paris, France
[2] Hop Bichat Claude Bernard, AP HP, Physiol Dept, 46 Rue Henri Huchard, F-75018 Paris, France
[3] Ctr Res Inflammat, INSERM, U1149, Paris, France
[4] Hop Europeen Georges Pompidou, AP HP, Physiol Dept, F-75015 Paris, France
[5] CNRS, Inst Necker Enfants Malad, INSERM, U1151,UMR8253, Paris, France
[6] Sorbonne Univ, Paris, France
[7] Hop Tenon, AP HP, Physiol Dept, F-75020 Paris, France
[8] Hop Tenon, AP HP, Dept Nucl Med, F-75020 Paris, France
[9] Univ Paris, Ctr Rech Cordeliers, INSERM, F-75006 Paris, France
[10] Hop Europeen Georges Pompidou, AP HP, Radiopharm Unit, F-75015 Paris, France
[11] Hop Bichat Claude Bernard, AP HP, Dept Nucl Med, F-75018 Paris, France
[12] Hop Bichat Claude Bernard, AP HP, Dept Radiol, F-75018 Paris, France
[13] Hop Bichat Claude Bernard, AP HP, Radiopharm Unit, F-75018 Paris, France
[14] INSERM, U1148, Lab Vasc Translat Res, F-75018 Paris, France
关键词
Glomerular filtration rate measurement; (51)cr-EDTA; (99m)tc-DTPA; Radio-labelled tracers; Plasma clearance; Renal clearance;
D O I
10.1007/s40620-020-00932-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose The production of Cr-51-labelled ethylenediaminetetraacetic acid (Cr-51-EDTA), a validated and widely used radio-isotopic tracer for glomerular filtration rate (GFR) measurement in Europe, was recently halted by the manufacturer. Technetium-99m-diethylenetriaminepentaacetic acid (Tc-99m-DTPA) clearance has so far mostly been restricted to assessment of separate renal function by scintigraphy, but scarcely used and validated for GFR measurement. We compared the performances of Cr-51-EDTA and Tc-99m-DTPA for GFR and extracellular fluid measurement. Methods In a multi-centre prospective study, Cr-51-EDTA and Tc-99m-DTPA were simultaneously injected into 88 patients, and their urinary and plasma clearances, as well as their volumes of distribution, were measured during seven 30-min periods after a 90-min equilibrium time. Results Mean age was 52.2 +/- 14.5 years, 59% were men. Urinary clearances of Cr-51-EDTA and Tc-99m-DTPA were 64.1 +/- 27.6 and 66.1 +/- 28.0 mL/min, respectively, with a mean bias of 2.00 +/- 2.25 mL/min, an accuracy within 10% of 95% [95% CI 91-99], and a coefficient of determination (R-2) of 0.994. Plasma clearances of Cr-51-EDTA and Tc-99m-DTPA were 66.1 +/- 25.8 and 68.1 +/- 26.6 mL/min, respectively, with a mean bias of 1.96 +/- 3.32 mL/min, an accuracy within 10% of 91% [95% CI 85-97] and a R-2 of 0.985. Distribution volumes were 17.3 +/- 4.6 L for Cr-51-EDTA and 16.6 +/- 4.6 L for Tc-99m-DTPA (R-2 0.930). Conclusion The accuracy and precision of Tc-99m-DTPA clearance, compared to Cr-51-EDTA clearance, was excellent for both urinary and plasma clearance methods, despite an approximate 2 mL/min overestimation, showing that the tracer is a reliable alternative to Cr-51-EDTA for GFR measurement. [GRAPHICS] .
引用
收藏
页码:729 / 737
页数:9
相关论文
共 26 条
  • [21] GLOMERULAR-FILTRATION RATE - A COMPARISON BETWEEN CR-EDTA CLEARANCE AND A SINGLE SAMPLE TECHNIQUE WITH A NONIONIC CONTRAST AGENT
    ERIKSSON, CG
    KALLNER, A
    CLINICAL BIOCHEMISTRY, 1991, 24 (03) : 261 - 264
  • [22] Comparison of GFR calculation methods: MDRD and CKD-EPI vs. 99mTc-DTPA tracer clearance rates
    Dias, Andre H.
    Pintao, Sophia
    Almeida, Pedro
    Martins, Teresa
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2013, 73 (04): : 334 - 338
  • [23] 99mTc-DMSA planar and SPECT-CT imaging and quantification in patients with sickle cell anemia: a comparison with glomerular filtration rate
    Onusic, D. M.
    Brunetto, S. Q.
    Pasquoto, J.
    Brunetto, E. M. R.
    Norberto, C. M. S.
    da Silva, N. T. T. P.
    Santos, A. O.
    de Lima, M. C. L.
    Amorim, B. J.
    Etchebehere, E. C. S. C.
    Saad, S. T. O.
    Ramos, C. D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S602 - S602
  • [24] Accuracy of next-day single-sample measurement for low glomerular filtration rate and comparison with same-day slope-intercept glomerular filtration rate
    McMeekin, Helena
    Wickham, Fred
    Fongenie, Ben
    Burniston, Maria
    NUCLEAR MEDICINE COMMUNICATIONS, 2021, 42 (02) : 169 - 172
  • [25] Can serum cystatin C reflect the glomerular filtration rate accurately in pediatric patients under chemotherapeutic treatment? A comparative study with Tc-99m DTPA two-plasma sample method
    Aydin, Funda
    Tezcan, Guelsuen
    Gungor, Ozguel
    Cengiz, Arzu Kin
    Hazar, Volkan
    Akman, Sema
    Guven, Ayfer Guer
    Yesilipek, Akif
    Akbas, Halide
    Gungor, Firat
    NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (04) : 301 - 306
  • [26] Comparison of GFR measurement with a two-blood sample technique using [99mTc]Tc-DTPA vs. creatinine-based equations in potential kidney donors
    Carvalho, Jose Pedro
    Marques, Andreia
    Abreu, Fernando
    Pintao, Sophia
    JORNAL BRASILEIRO DE NEFROLOGIA, 2023, 45 (03): : 344 - 349