New Fe(II) Ion-selective electrode based On N-Phenylaza-15-Crown-5 as neutral carrier in PVC matrix

被引:26
作者
Aghaie, M. [2 ]
Giahi, M. [1 ]
Aghaie, H. [3 ]
Arvand, M. [4 ]
Pournaghdy, M. [3 ]
Yavari, F. [1 ]
机构
[1] Islamic Azad Univ, Fac Sci, Lahijan Branch, Dept Chem, Lahijan, Iran
[2] Islamic Azad Univ, N Tehran Branch, Dept Chem, Tehran, Iran
[3] Islamic Azad Univ, Dept Chem, Tehran, Iran
[4] Univ Guilan, Fac Sci, Dept Chem, Rasht, Iran
关键词
Fe(II)-selective electrode; Stability constant; PVC membrane; N-phenylaza-15-crown-5; BULK OPTODES; CROWN-ETHER; MEMBRANE; IONOPHORES; SENSORS; COEFFICIENTS; CONSTANTS;
D O I
10.1016/j.desal.2008.10.007
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A new polyvinyl chloride (PVC) membrane electrode that is highly selective to Fe(II) ions was prepared using N-phenylaza-15-crown-5 (NPA15C5) as a suitable neutral carrier. The sensor exhibits a Nernstian response for Fe(II) ions over a wide concentration range (1.0 x 10(-2) to 1.0 x 10(-6) M) with a slope of 29.2 +/- 0.6 mV per decade. It has a response time of <15 s and can be used for at least 2 months without any measurable divergence in potential. The proposed sensor shows a fairly good discriminating ability towards Fe(2+) ion in comparison with some hard and soft metal ions. The isothermal temperature coefficient of this electrode amounted to 0.0017 V/degrees C. The stability constant (log K(s)) of the Fe(II)-NPA15C5 complex was determined at 25 degrees C by potentiometric titration in mixed aqueous solution. The results show that this electrode can be used in ethanol and dioxane media up to 20% and 5% (v/v) concentration, respectively, without interference. The electrode was used for direct determination of Fe(2+) in the ferrous sulfate syrup.
引用
收藏
页码:346 / 354
页数:9
相关论文
共 40 条
  • [31] MANGANESE(II)-ION-SELECTIVE ELECTRODE BASED ON 2,2′-BIS(SALICYLIDENEAMINO) AZOBENZENE INCORPORATED IN POLY(VINYL CHLORIDE) MATRIX
    Gholivand, Mohammad Bagher
    Gorji, Maryam
    Joshaghani, Mohammad
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2009, 74 (09) : 1411 - 1424
  • [32] Ion-selective potentiometric determination of Pb(II) ions using PVC-based carboxymethyl cellulose Sn(IV) phosphate composite membrane electrode
    Inamuddin
    Naushad, Mu.
    Rangreez, Tauseef Ahmad
    ALOthman, Z. A.
    DESALINATION AND WATER TREATMENT, 2015, 56 (03) : 806 - 813
  • [33] Nickel(II) ion-selective electrode based on 2,5-thiophenyl bis(5-tert-butyl-1,3-benzoxazole)
    Ganjali, MR
    Hosseini, SM
    Javanbakht, M
    Hashemi, OR
    ANALYTICAL LETTERS, 2000, 33 (15) : 3139 - 3152
  • [34] Electroanalytical Studies on Cobalt(II) Ion-Selective Sensor of Polymeric Membrane Electrode and Coated Graphite Electrode Based on N2O2 Salen Ligands
    Bandi, Koteswara Rao
    Singh, Ashok Kumar
    Jain, Kamaluddin A. K.
    Gupta, V. K.
    ELECTROANALYSIS, 2011, 23 (12) : 2839 - 2850
  • [35] CHARACTERIZATION OF A NEW Ag+-SELECTIVE ELECTRODE BASED ON N3S5-THIAAZACROWN ETHER AS NEUTRAL IONOPHORE
    Zhang, Jun
    Ding, Jia Wang
    Qin, Wei
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2011, 56 (01) : 580 - 583
  • [36] Thiocyanate-selective PVC membrane electrodes based on Mn(II) complex of N,N′-bis-(4-phenylazosalicylidene) o-phenylene diamine as a neutral carrier
    Li, ZQ
    Wu, ZY
    Yuan, R
    Ying, M
    Shen, GL
    Yu, RQ
    ELECTROCHIMICA ACTA, 1999, 44 (15) : 2543 - 2548
  • [37] Investigation of poly(3,4-ethylenedioxythiophene) deposition method influence on properties of ion-selective electrodes based on bis(benzo15-crown-5) derivatives
    Jeszke, Maciej
    Trzcinski, Konrad
    Karczewski, Jakub
    Luboch, Elzbieta
    ELECTROCHIMICA ACTA, 2017, 246 : 424 - 432
  • [38] A Novel all Solid-State Contact PVC-Membrane Beryllium-Selective Electrode Based on 4-Hydroxybenzo-15-Crown-5 Ether Ionophore
    Isildak, Ibrahim
    Attar, Azade
    Demir, Ersin
    Kemer, Baris
    Aboul-Enein, Hassan Y.
    CURRENT ANALYTICAL CHEMISTRY, 2018, 14 (01) : 43 - 48
  • [39] A new Zn2+-selective sensor based on 5,10,15,20-tetraphenyl-21H,23H-porphine in PVC matrix
    Gupta, VK
    Jain, AK
    Mangla, R
    Kumar, P
    ELECTROANALYSIS, 2001, 13 (12) : 1036 - 1040
  • [40] A fast response cadmium-selective polymeric membrane electrode based on N,N'-(4-methyl-1,2-phenylene)diquinoline-2-carboxamide as a new neutral carrier
    Rezaei, B.
    Meghdadi, S.
    Zarandi, R. Fazel