New Fe(II) Ion-selective electrode based On N-Phenylaza-15-Crown-5 as neutral carrier in PVC matrix

被引:26
|
作者
Aghaie, M. [2 ]
Giahi, M. [1 ]
Aghaie, H. [3 ]
Arvand, M. [4 ]
Pournaghdy, M. [3 ]
Yavari, F. [1 ]
机构
[1] Islamic Azad Univ, Fac Sci, Lahijan Branch, Dept Chem, Lahijan, Iran
[2] Islamic Azad Univ, N Tehran Branch, Dept Chem, Tehran, Iran
[3] Islamic Azad Univ, Dept Chem, Tehran, Iran
[4] Univ Guilan, Fac Sci, Dept Chem, Rasht, Iran
关键词
Fe(II)-selective electrode; Stability constant; PVC membrane; N-phenylaza-15-crown-5; BULK OPTODES; CROWN-ETHER; MEMBRANE; IONOPHORES; SENSORS; COEFFICIENTS; CONSTANTS;
D O I
10.1016/j.desal.2008.10.007
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A new polyvinyl chloride (PVC) membrane electrode that is highly selective to Fe(II) ions was prepared using N-phenylaza-15-crown-5 (NPA15C5) as a suitable neutral carrier. The sensor exhibits a Nernstian response for Fe(II) ions over a wide concentration range (1.0 x 10(-2) to 1.0 x 10(-6) M) with a slope of 29.2 +/- 0.6 mV per decade. It has a response time of <15 s and can be used for at least 2 months without any measurable divergence in potential. The proposed sensor shows a fairly good discriminating ability towards Fe(2+) ion in comparison with some hard and soft metal ions. The isothermal temperature coefficient of this electrode amounted to 0.0017 V/degrees C. The stability constant (log K(s)) of the Fe(II)-NPA15C5 complex was determined at 25 degrees C by potentiometric titration in mixed aqueous solution. The results show that this electrode can be used in ethanol and dioxane media up to 20% and 5% (v/v) concentration, respectively, without interference. The electrode was used for direct determination of Fe(2+) in the ferrous sulfate syrup.
引用
收藏
页码:346 / 354
页数:9
相关论文
共 40 条
  • [1] New Ni(II) Ion-Selective Electrode Based on the N-S Schiff Base Ligand as Neutral Carrier in PVC Matrix
    Ma, Yu-Hua
    Yuan, Ruo
    Chai, Ya-Qin
    Wu, Xia
    Zhou, Wei
    Liu, Xin-Lu
    Deng, Fan
    ANALYTICAL LETTERS, 2009, 42 (15) : 2411 - 2429
  • [2] CdO nanoparticles: robust inorganic additive for cadmium selective polymeric electrode based on N-phenylaza-15-crown-5
    Ghadaksaz, Anis Golab
    Ghaemi, Arezoo
    Kakhki, Roya Mohammadzadeh
    JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2021, 101 (1-2) : 139 - 148
  • [3] Strontium Ion-Selective Electrode Based on 18-Crown-6 in PVC Matrix
    Arbab-Zavar, Mohammad Hossein
    Rounagh, Gholam Hossein
    Fahmideh-Rad, Elham
    ASIAN JOURNAL OF CHEMISTRY, 2009, 21 (03) : 2224 - 2232
  • [4] Preparation and Application of Potassium Ion-Selective Membrane Electrode Based on Benzo-15-Crown-5 Ether
    Sendil, Olcay
    Pecenek, Erdal
    Ekmekci, Gueler
    Somer, Gueler
    CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (01) : 53 - 58
  • [5] Pentacyclooctaaza as a neutral carrier in coated-wire ion-selective electrode for nickel(II)
    Mazloum-Ardakani, M
    Salavati-Niasari, M
    Amini, MK
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 82 (2-3) : 259 - 264
  • [6] Manganese(II) Ion-Selective Membrane Electrode Based on N-(2-picolinamido ethyl)-Picolinamide as Neutral Carrier
    Aghaie, M.
    Giahi, M.
    Zawari, M.
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (10) : 2980 - 2984
  • [7] A New PVC-Membrane Based Ion-Selective Electrode for Perchlorate
    Yari, Abdollah
    Shamsipur, Mojtaba
    De Filippo, Greta
    Lippolis, Vito
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2009, 1 (02): : 60 - 70
  • [8] Development of a new copper(II) ion-selective PVC membrane electrode based on tris(2-benzimidazolylmethyl)amine
    Tomar, Praveen Kumar
    Chandra, Sulekh
    Singh, Inderjeet
    Kumar, Avdhesh
    Malik, Amrita
    Singh, Arendra
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2011, 88 (11) : 1739 - 1744
  • [9] New Copper(II) Ion-Selective Membrane Electrode Based on Erythromycin Ethyl Succinate as a Neutral Ionophore
    Sadeghi, Susan
    Jahani, Moslem
    ANALYTICAL LETTERS, 2009, 42 (13) : 2026 - 2040
  • [10] A Novel Ion-Selective Electrode for Determination of the Mercury(II) Ion Based on Schiff Base as a Carrier
    Zhang, M.
    Wu, X.
    Chai, Y. Q.
    Yuan, R.
    Ye, G. R.
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2008, 55 (06) : 1345 - 1350