A Low-Order System Frequency Response Model for DFIG Distributed Wind Power Generation Systems Based on Small Signal Analysis

被引:10
|
作者
Quan, Rui [1 ,2 ]
Pan, Wenxia [1 ,2 ]
机构
[1] Hohai Univ, Coll Energy & Elect Engn, Nanjing 210098, Jiangsu, Peoples R China
[2] Hohai Univ, Res Ctr Renewable Energy Generat Engn, Minist Educt, Nanjing 210098, Jiangsu, Peoples R China
来源
ENERGIES | 2017年 / 10卷 / 05期
关键词
dynamic frequency response characteristic; low-order; small signal analysis; distributed wind power generation systems; auxiliary frequency controller; FED INDUCTION GENERATOR; TURBINES; INERTIA; SUPPORT;
D O I
10.3390/en10050657
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Integrating large amounts of wind power into power systems brings a large influence on the dynamic frequency response characteristic (DFRC). The traditional low-order system frequency response (SFR) model is no longer applicable at the current time. Based on the small signal analysis theory, a set of novel low-order SFR models for doubly-fed induction generator (DFIG) distributed wind power generation systems (DWPGS) are derived under low, medium, and high wind speed conditions, respectively. Time-domain simulations have been conducted on PSCAD/EMTDC, and the novel SFR model is tested and evaluated on a real system. The simulation results from the novel model agree with those from the detailed model. The novel SFR model can also directly show the impact of the initial wind speed and auxiliary frequency controller (AFC) parameters on DFRC, but not on the detailed model.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Model order reduction analysis of DFIG integration on the power system small-signal stability considering the virtual inertia control
    Ma, Jing
    Song, Zhanxiang
    Zhang, Yongxin
    Shen, Yaqi
    Thorp, James S.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (16) : 4087 - 4095
  • [42] Using adaptive control in DFIG-based wind turbine systems to inhibit power system low-frequency oscillations
    Asefi, Mohammad-Naser
    Jafarian, Mohammad
    Taherahmadi, Javad
    JOURNAL OF ENGINEERING-JOE, 2019, (18): : 4687 - 4691
  • [43] Impact of Increased Penetration of DFIG based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems
    Gautam, Durga
    Vittal, Vijay
    Harbour, Terry
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [44] Probabilistic Analysis of Small Signal Stability for Power Systems With High Penetration of Wind Generation
    Wang, Z. W.
    Shen, C.
    Liu, F.
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2016, 7 (03) : 1182 - 1193
  • [45] Analysis of effect of layup material layer thickness on low-order model frequency of wind turbine blades
    Zheng, Yuqiao
    Ma, Huidong
    Lu, Bingxi
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (09): : 337 - 342
  • [46] Wind farm density and harvested power in very large wind farms: A low-order model
    Cortina, G.
    Sharma, V.
    Calaf, M.
    PHYSICAL REVIEW FLUIDS, 2017, 2 (07):
  • [47] Dynamic Response of Wind Power Generation Based on DFIG under Grid Fault
    Guo Jia-Hu
    Zhang Lu-hua
    Cai Xu
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1443 - 1446
  • [48] Analysis on DFIG Wind Power System Low-Voltage Ridethrough
    Wang Yulong
    Li Jianlin
    Hu Shuju
    Xu Honghua
    FIRST IITA INTERNATIONAL JOINT CONFERENCE ON ARTIFICIAL INTELLIGENCE, PROCEEDINGS, 2009, : 676 - 679
  • [49] Dynamic response of wind power generation based on DFIG under grid fault
    Guo, Jiahu
    Zhang, Luhua
    Cai, Xu
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2010, 31 (08): : 1023 - 1029
  • [50] Small Signal Stability Analysis of Power Systems with DDSG Based Wind Power Penetration
    Mehta, Bhinal
    Bhatt, Praghnesh
    Pandya, Vivek
    2014 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (IEEE PES APPEEC), 2014,