A fast and reliable fault diagnosis method for fault tolerant shunt three-phase active filter

被引:0
|
作者
El Brouji, H. [1 ]
Poure, P. [2 ]
Saadate, S. [1 ]
机构
[1] Univ Nancy 1, CNRS UMR 7037, GREEN, Grp Rech Electrotech & Elect Nancy, BP 239, F-54506 Vandoeuvre Les Nancy, France
[2] Univ Nancy 1, EA 3440, LIEN, Lab Intrumentat Elect Nancy, F-54506 Vandoeuvre Les Nancy, France
来源
2006 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-7 | 2006年
关键词
active power filter; fault tolerant converter topology; fault detection; converter reconfiguration; fault tolerant control;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a fault tolerant shunt three phase active filter topology. It mainly details converter reconfiguration and examined a fast and reliable optimised fault diagnosis method. This method avoids spurious semi conductor fault detection due to semi conductor switching. The converter topology is based on classical three-leg active power filter topology but includes bi-directional switches for converter reconfiguration. after fault detection. The resulting post fault power structure is a two-leg topology with fault leg connected to the middle point of the filtering capacitor. A new fault diagnosis method is proposed, based on classical voltage measurements. It includes combinatory logic to analyse and validate error signals. An unique control is applied before and after fault detection, which avoids any controller reconfiguration. Simulation results obtained with Saber CAD tools validate the theoretical study and the modelisations.
引用
收藏
页码:1688 / +
页数:2
相关论文
共 50 条
  • [21] A method for three-phase fault lost directivity
    Wang, Zhong
    Yu, Hong
    Li, Juan
    Lu, Jun
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (09): : 122 - 125
  • [22] Fault Indicator Three-Phase Synchronization Method Based on Fault Instant
    Zhao, Qian
    Gao, Houlei
    Yuan, Tong
    Li, Lin
    Wang, Gang
    2022 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA (I&CPS ASIA 2022), 2022, : 275 - 281
  • [23] Open-Phase Fault-Tolerant Operation of the Three-Phase Dual Active Bridge Converter
    Berger, Maxitne
    Kocar, Ilhan
    Fortin-Blanchette, Handy
    Lavertu, Carl
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (04) : 3651 - 3662
  • [24] Fault tolerant control based on active fault diagnosis
    Niemann, H
    ACC: PROCEEDINGS OF THE 2005 AMERICAN CONTROL CONFERENCE, VOLS 1-7, 2005, : 2224 - 2229
  • [25] FPGA-based fully digital fast power switch fault detection and compensation for three-phase shunt active filters
    Karimi, S.
    Poure, P.
    Saadate, S.
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (11) : 1933 - 1940
  • [26] Open Circuit Fault Diagnosis and Fault Tolerance of Three-Phase Bridgeless Rectifier
    Cheng, Hong
    Chen, Wenbo
    Wang, Cong
    Deng, Jiaqing
    ELECTRONICS, 2018, 7 (11):
  • [27] Active Common-Mode Voltage Reduction in a Fault-Tolerant Three-Phase Inverter
    Mohammadi, Danyal
    Ahmed-Zaid, Said
    APEC 2016 31ST ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, 2016, : 2821 - 2825
  • [28] Control Method of the Three-Phase Four-Leg Shunt Active Power Filter
    Li Bin
    Tong Minyong
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 1825 - 1830
  • [29] Fault tolerant control of a three-phase PMSM by limiting the heat of an inter-turn fault
    Foitzik, Simon
    Doppelbauer, Martin
    IET ELECTRIC POWER APPLICATIONS, 2022, 16 (02) : 158 - 168
  • [30] A fault diagnosis method for three-phase photovoltaic grid-connected inverter
    Geng, Yiwen, 1600, China Machine Press (29):