Ten-year follow-up of the non-porous Allofit cementless acetabular component

被引:21
作者
Zenz, P. [1 ]
Stiehl, J. B. [1 ]
Knechtel, H. [1 ]
Titzer-Hochmaier, G. [1 ]
Schwagerl, W. [1 ]
机构
[1] OttoWagnerSpital, A-1140 Vienna, Austria
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2009年 / 91B卷 / 11期
关键词
TOTAL HIP-ARTHROPLASTY; POROUS TANTALUM BIOMATERIAL; PRESS-FIT STABILITY; PRIMARY OSTEOARTHRITIS; SCREW FIXATION; CUP FIXATION; THREADED CUP; OSTEOLYSIS; METAL; SOCKETS;
D O I
10.1302/0301-620X.91B11.22368
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Cementless acetabular fixation has demonstrated superior long-term durability in total hip replacement, but most series have studied implants with porous metal surfaces. We retrospectively evaluated the results of 100 consecutive patients undergoing total hip replacement where a non-porous Allofit component was used for primary press-fit fixation. This implant is titanium alloy, grit-blasted, with a macrostructure of forged teeth and has a biradial shape. A total of 81 patients (82 hips) were evaluated at final follow-up at a mean of 10.1 years (8.9 to 11.9). The Harris Hip Score improved from a mean 53 points ( 23 to 73) pre-operatively to a mean of 96 points (78 to 100) at final review. The osseointegration of all acetabular components was radiologically evaluated with no evidence of loosening. The survival rate with revision of the component as the endpoint was 97.5% (95% confidence interval 94 to 100) after 11.9 years. Radiolucency was found in one DeLee-Charnley zone in four acetabular components. None of the implants required revision for aseptic loosening. Two patients were treated for infection, one requiring a two-stage revision of the implant. One femoral stem was revised for osteolysis due to the production of metal wear debris, but the acetabular shell did not require revision. This study demonstrates that a non-porous titanium acetabular component with adjunct surface fixation offers an alternative to standard porous-coated implants.
引用
收藏
页码:1443 / 1447
页数:5
相关论文
共 44 条
[1]  
Adler E, 1992, J Arthroplasty, V7, P295, DOI 10.1016/0883-5403(92)90052-R
[2]   TRANSGLUTEAL APPROACH TO THE HIP-JOINT [J].
BAUER, R ;
KERSCHBAUMER, F ;
POISEL, S ;
OBERTHALER, W .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 95 (1-2) :47-49
[3]  
BEAULE PE, 2001, CLIN ORTHOP RELAT R, V386, P159
[4]   Nonmodular flexible press-fit cup in primary total hip arthroplasty - 15-year followup [J].
Berli, Bernhard J. ;
Ping, Gu ;
Dick, Walter ;
Morscher, Erwin W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (461) :114-121
[5]   Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial [J].
Bobyn, JD ;
Stackpool, GJ ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :907-914
[6]   Clinical validation of a structural porous tantalum biomaterial for adult reconstruction [J].
Bobyn, JD ;
Poggie, RA ;
Krygier, JJ ;
Lewallen, DG ;
Hanssen, AD ;
Lewis, RJ ;
Unger, AS ;
O'Keefe, TJ ;
Christie, MJ ;
Nasser, S ;
Wood, JE ;
Stulberg, SD ;
Tanzer, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A :123-129
[7]   Tissue response to porous tantalum acetabular cups - A canine model [J].
Bobyn, JD ;
Toh, KK ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF ARTHROPLASTY, 1999, 14 (03) :347-354
[8]   High failure rate of cementless threaded acetabular cups - A radiographic and histologic study in the goat [J].
Bruijn, JD ;
Seelen, JL ;
Veldhuizen, RW ;
Feenstra, RM ;
Bernoski, FP ;
Klopper, PJ .
ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (02) :133-137
[9]   Osteolysis in patients with a metal-on-metal hip arthroplasty [J].
Carr, Ashley M. ;
Desteiger, Richard .
ANZ JOURNAL OF SURGERY, 2008, 78 (03) :144-147
[10]   A ten-year follow-up of the Reflection cementless acetabular component [J].
Civinini, R. ;
D'Arienzo, M. ;
Innocenti, M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (05) :570-573