Near-Infrared Spectroscopic Evaluation of the Water Content of Molded Polylactide under the Effect of Crystallization

被引:11
|
作者
Muroga, Shun [1 ]
Hikima, Yuta [1 ]
Ohshima, Masahiro [1 ]
机构
[1] Kyoto Univ, Dept Chem Engn, Kyoto, Japan
关键词
Near-infrared; spectroscopy; NIR; polylactide; PLA; hydrolysis; moisture; crystallization; crystallinity; partial least squares regression; PLS; POLY(LACTIC ACID); HYDROLYTIC DEGRADATION; LACTIC-ACID; POLY(L-LACTIC ACID); MOISTURE-CONTENT; SPECTROMETER; BLENDS; TISSUE; PLA; DIFFERENTIATION;
D O I
10.1177/0003702816681011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
During melt processing, the moisture inside polylactide (PLA) easily induces hydrolysis, which deteriorates the mechanical and thermal properties of the product. The state of dryness of resin pellets must be monitored to prevent PLA hydrolysis. In this study, near-infrared (NIR) spectroscopy was applied to measure water content in PLA. In addition, the shape of the NIR spectrum is also affected by crystallization, which could lead to a reduction in the accuracy of evaluating the water content. The objective of this research is to construct a robust model for estimating the water content with varying dispersive extents of crystallization. Two methods for estimating water content measured during a drying process were conducted: the integration of absorbance and partial least squares (PLS) regression were conducted to estimate the water contents in PLA considering the effect of crystallization. The slope of the calibration line of the water content obtained from integrating absorbance varied between PLA with different crystallinities. This is due to the overlap between the NIR band of water and that of PLA crystal in the range of 5100-5400cm(-1). We found that the shape of the NIR spectrum was changed by crystallization, and the crystallinity, compared to the thickness of lamellae, was the dominant factor determining such a change of NIR spectra. The PLS model of water content constructed from only amorphous PLA showed large error of estimation in crystallized PLA. In contrast, the PLS model constructed from both amorphous and crystallized PLA estimated the water contents with lower errors. This was because latent variables obtained from both amorphous and crystallized PLA cancelled the effect of crystallization on NIR spectra.
引用
收藏
页码:1300 / 1309
页数:10
相关论文
共 50 条
  • [1] The Effect of Heat Treatment on Water Sorption in Polylactide and Polylactide Composites via Changes in Glass-Transition Temperature and Crystallization Kinetics
    Du, An
    Koo, Donghun
    Ziegler, Mary
    Cairncross, Richard A.
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2011, 49 (12) : 873 - 881
  • [2] Near-Infrared Spectroscopic Method for Monitoring Water Content in Epoxy Resins and Fiber-Reinforced Composites
    Krauklis, Andrey E.
    Gagani, Abedin I.
    Echtermeyer, Andreas T.
    MATERIALS, 2018, 11 (04):
  • [3] NEAR-INFRARED SPECTROSCOPIC MEASUREMENT OF PROTEIN-CONTENT IN OIL-WATER EMULSIONS
    KAMISHIKIRYO, H
    HASEGAWA, K
    TAKAMURA, H
    MATOBA, T
    JOURNAL OF FOOD SCIENCE, 1992, 57 (05) : 1239 - 1241
  • [4] Evaluation of near-infrared chemical imaging for the prediction of surface water quality parameters
    O' Reilly, Aodhagan
    Coffey, Rory
    Gowen, Aoife
    Cummins, Enda
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2015, 95 (05) : 403 - 418
  • [5] Near-infrared imaging of water in human hair
    Egawa, Mariko
    Hagihara, Motofumi
    Yanai, Motohiro
    SKIN RESEARCH AND TECHNOLOGY, 2013, 19 (01) : 35 - 41
  • [6] Near-Infrared Spectroscopic Evaluation of Lyophilized Viral Vaccine Formulations
    Hansen, Laurent
    De Beer, Thomas
    Pieters, Sigrid
    Vander Heyden, Yvan
    Vervaet, Chris
    Remon, Jean Paul
    Montenez, Jean-Pierre
    Daoussi, Rim
    BIOTECHNOLOGY PROGRESS, 2013, 29 (06) : 1573 - 1586
  • [7] Visualization of hydrolysis in polylactide using near-infrared hyperspectral imaging and chemometrics
    Muroga, Shun
    Hikima, Yuta
    Ohshima, Masahiro
    JOURNAL OF APPLIED POLYMER SCIENCE, 2018, 135 (08)
  • [8] Vanilla content evaluation in cured bean by near-infrared technique
    Wongsheree, T.
    Rittiron, R.
    Wongs-Aree, C.
    Thongtheing, T.
    XXIX INTERNATIONAL HORTICULTURAL CONGRESS ON HORTICULTURE: SUSTAINING LIVES, LIVELIHOODS AND LANDSCAPES (IHC2014): INTERNATIONAL SYMPOSIA ON ABSCISSION PROCESSES IN HORTICULTURE AND NON-DESTRUCTIVE ASSESSMENT OF FRUIT ATTRIBUTES, 2016, 1119 : 297 - 303
  • [9] Spectroscopic measurement of water using an electrostatic transducer with near-infrared absorber
    Suzuki, Takamasa
    Nakafuji, Kota
    Uesugi, Akio
    Sugano, Koji
    Isono, Yoshitada
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2021, 104 (04)
  • [10] Comparison of Individual and Integrated Inline Raman, Near-Infrared, and Mid-Infrared Spectroscopic Models to Predict the Viscosity of Micellar Liquids
    Haroon, Kiran
    Arafeh, Ali
    Cunliffe, Stephanie
    Martin, Philip
    Rodgers, Thomas
    Mendoza, Cesar
    Baker, Michael
    APPLIED SPECTROSCOPY, 2020, 74 (07) : 819 - 831