Nocturnal blood pressure dipping: A consequence of diurnal physical activity blipping?

被引:53
作者
O'Shea, JC
Murphy, MB
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Therapeut & Pharmacol, Cork, Ireland
[2] Mercy Hosp, Cork, Ireland
关键词
ambulatory blood pressure monitoring; diurnal blood pressure variation; physical activity; actigraph;
D O I
10.1016/S0895-7061(99)00263-0
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
This study was designed to describe the interaction between physical activity (PA), quantified objectively by electronic activity monitors, and ambulatory blood pressure (ABP), and to test the hypothesis that modifying daily PA can effect significant changes in the diurnal variation in blood pressure and may result in altered dipping/nondipping status of an individual. Initially, 70 individuals underwent simultaneous ABP and electronic activity monitoring (actigraph devices manufactured by Gaewihler Electronics, Switzerland) over a 24-h period. Then, in a prospective study, the dipping/nondipping status of 43 subjects was assessed using ABP recorded over two 24-h periods of differing activity levels. Of the 70 subjects (age 49 +/- 11 years, 42 male) the diurnal variation in systolic blood pressure (20 +/- 12%, step-up from night [120 +/- 12 mm Hg] to day [144 +/- 13 mm Hg]) and diurnal variation in PA score (increment from sleep, 44 +/- 17 units) correlated significantly (R-2 = 0.29; P < .05). Of the 43 subjects who underwent ABP monitoring on a more active day, four had a nondipping BP profile; 12 of these same 43 subjects had a nondipping BP profile when monitored on a less active day (chi(2) = 4.9; P < .05). These results provide a quantitative description of the contribution of PA, including the sleep/awake status, to blood pressure variation in a group of normotensive and hypertensive individuals. The magnitude of this effect underscores the importance of interpreting 24-h ABP data only in the presence of adequately quantified activity data. Am J Hypertens 2000; 13:601-606 (C) 2000 American Journal of Hypertension, Ltd.
引用
收藏
页码:601 / 606
页数:6
相关论文
共 24 条
  • [11] CLINICAL USE OF AMBULATORY BLOOD-PRESSURE MONITORING
    MANCIA, G
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1989, 2 (02) : S50 - S54
  • [12] OShea JC, 1997, AM J HYPERTENS, V10, P175
  • [13] Pickering TG, 1997, J HUM HYPERTENS, V11, pS9
  • [14] A COMPARISON OF AMBULATORY BLOOD-PRESSURE AND HEART-RATE AT HOME AND WORK ON WORK AND NONWORK DAYS
    PIEPER, C
    WARREN, K
    PICKERING, TG
    [J]. JOURNAL OF HYPERTENSION, 1993, 11 (02) : 177 - 183
  • [15] SUPPRESSION OF ALCOHOL-INDUCED HYPERTENSION BY DEXAMETHASONE
    RANDIN, D
    VOLLENWEIDER, P
    TAPPY, L
    JEQUIER, E
    NICOD, P
    SCHERRER, U
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (26) : 1733 - 1737
  • [16] REAL-TIME DETECTION OF SIGNIFICANT BLOOD-PRESSURE EVENTS IN AMBULANT SUBJECTS
    ROFFE, DJ
    BERTRAM, CD
    HUNYOR, SN
    [J]. CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1985, 7 (2-3) : 299 - 307
  • [17] SHIMADA K, 1992, J HYPERTENS, V10, P875
  • [18] CAN SIMULTANEOUS AMBULATORY BLOOD-PRESSURE AND ACTIVITY MONITORING IMPROVE THE DEFINITION OF BLOOD-PRESSURE
    STEWART, MJ
    BROWN, H
    PADFIELD, PL
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1993, 6 (06) : S174 - S178
  • [19] STEWART MJ, 1996, J HYPERTENS, V14, P1501
  • [20] A COMPUTER-ASSISTED DIARY (CAD) FOR AMBULATORY BLOOD-PRESSURE MONITORING
    VANEGEREN, LF
    MADARASMI, S
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1988, 1 (03) : S179 - S185