Experimental investigations on timber joints with single glued-in FRP rods

被引:36
作者
Zhu, Hong [1 ]
Faghani, Pedram [2 ]
Tannert, Thomas [3 ]
机构
[1] UBC Vancouver, Wood Sci, Vancouver, BC, Canada
[2] UBC Vancouver, Civil Engn, Vancouver, BC, Canada
[3] UBC Vancouver, Wood Sci & Civil Engn, Vancouver, BC, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Timber; Glued-in rods; Fibre reinforced polymers; Failure modes; CONNECTIONS; BARS;
D O I
10.1016/j.conbuildmat.2017.02.091
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Glued-in rods form very stiff connections and can be used to effectively connect structural timber members without disrupting their visible exterior. The use of fibre-reinforced polymer (FRP) rods provides additional benefits: lower weight, increased resistance to corrosion in acid or humid environments, and lower heat conduction into the joint in case of fire due to lower thermal conductivity. The research presented herein established benchmark data for the load-carrying capacity of joints with single glued-in glass-FRP rods using symmetric specimens and subsequently determined the residual load-carrying capacity of the surviving second sides. A total of 250 specimens with five different embedment lengths and five different rod diameters were tested under quasi-static uni-axial tension load. It was found that the joints always failed in a brittle manner, the load-carrying capacity increased with anchorage length up to an apparent maximum and that load-carrying capacities of the surviving connection ends were higher than the capacities of those that failed during the first tests. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 30 条