共 50 条
Optimal coefficient of performance and heating load relationship of a three-heat-reservoir endoreversible heat pump
被引:26
|作者:
Chen, LG
Wu, C
Sun, F
机构:
[1] Faculty 306, Naval Academy of Engineering
[2] Mechanical Engineering Department, US Naval Academy, Annapolis
关键词:
heat pump;
endoreversible;
performance;
non-linear heat transfer;
D O I:
10.1016/S0196-8904(96)00085-4
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
The relationship between optimal COP (coefficient of performance) and heating load of a three-heat-reservoir endoreversible heat pump (including both temperature amplifier and heat amplifier cycles) with non-linear heat transfer (phenomenological law in irreversible thermodynamics) is derived. The results presented in this paper are different from those obtained with a linear heat transfer law. The relationships provide a theoretical basis for developing and utilizing a variety of three-heat-reservoir heat pumps. (C) 1997 Elsevier Science Ltd.