Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a 'modern' pacemaker

被引:54
作者
Gimbel, J. Rod [1 ]
机构
[1] E Tennessee Heart Consultants, Knoxville, TN USA
来源
EUROPACE | 2009年 / 11卷 / 09期
关键词
CARDIAC-PACEMAKERS; SAFETY; DEVICES;
D O I
10.1093/europace/eup162
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pacemaker patients might safely undergo magnetic resonance imaging (MRI) if several prudent suggestions are followed by the supervising physician. Controversy exists regarding the safety of scanning all device patients, but especially pacemaker-dependent patients. Despite following suggestions previously proposed, physicians should be prepared for unexpected potentially life-threatening events during the conduct of MRI.
引用
收藏
页码:1241 / 1242
页数:2
相关论文
共 10 条
[1]   Pacemaker complication during magnetic resonance imaging - Reply [J].
Coman, JA ;
Martin, ET .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (01) :162-162
[2]   Magnetic resonance Imaging of Implantable cardiac rhythm devices at 3.0 tesla [J].
Gimbel, J. Rod .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (07) :795-801
[3]   Strategies for the safe magnetic resonance imaging of pacemaker-dependent patients [J].
Gimbel, JR ;
Bailey, SM ;
Tchou, PJ ;
Ruggieri, PM ;
Wilkoff, BL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (10) :1041-1046
[4]   Safety of magnetic resonance imaging in patients with cardiovascular devices - An American Heart Association scientific statement from the committee on diagnostic and interventional cardiac catheterization, council on clinical cardiology, and the council on cardiovascular radiology and intervention [J].
Levine, Glenn N. ;
Gomes, Antoinette S. ;
Arai, Andrew E. ;
Bluemke, David A. ;
Flamm, Scott D. ;
Kanal, Emanuel ;
Manning, Warren J. ;
Martin, Edward T. ;
Smith, J. Michael ;
Wilke, Norbert ;
Shellock, Frank S. .
CIRCULATION, 2007, 116 (24) :2878-2891
[5]   Safety of Brain 3-T MR Imaging with Transmit-Receive Head Coil in Patients with Cardiac Pacemakers: Pilot Prospective Study with 51 Examinations [J].
Naehle, Claas P. ;
Meyer, Carsten ;
Thomas, Daniel ;
Remerie, Susann ;
Krautmacher, Carsten ;
Litt, Harold ;
Luechinger, Roger ;
Fimmers, Rolf ;
Schild, Hans ;
Sommer, Torsten .
RADIOLOGY, 2008, 249 (03) :991-1001
[6]   Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe - In vitro and in vivo assessment of safety and function at 1.5 T [J].
Roguin, A ;
Zviman, MM ;
Meininger, GR ;
Rodrigues, ER ;
Dickfeld, TM ;
Bluemke, DA ;
Lardo, A ;
Berger, RD ;
Calkins, H ;
Halperin, HR .
CIRCULATION, 2004, 110 (05) :475-482
[7]   Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices [J].
Roguin, Ariel ;
Schwitter, Juerg ;
Vahlhaus, Christian ;
Lombardi, Massimo ;
Brugada, Josep ;
Vardas, Panos ;
Auricchio, Angelo ;
Priori, Silvia ;
Sommer, Torsten .
EUROPACE, 2008, 10 (03) :334-344
[8]   Pacemaker complication during magnetic resonance imaging [J].
Rozner, MA ;
Burton, AW ;
Kumar, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (01) :161-162
[9]   Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients - A prospective study with 115 examinations [J].
Sommer, Torsten ;
Naehle, Claas P. ;
Yang, Alexander ;
Zeijlemaker, Volkert ;
Hackenbroch, Matthias ;
Schmiedel, Alexandra ;
Meyer, Carsten ;
Strach, Katharina ;
Skowasch, Dirk ;
Vahlhaus, Christian ;
Litt, Harold ;
Schild, Hans .
CIRCULATION, 2006, 114 (12) :1285-1292
[10]   Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: clinical study design [J].
Sutton, Richard ;
Kanal, Emanuel ;
Wilkoff, Bruce L. ;
Bello, David ;
Luechinger, Roger ;
Jenniskens, Inge ;
Hull, Michael ;
Sommer, Torsten .
TRIALS, 2008, 9 (1)