Composite plate and wire fixation for complicated sternal closure

被引:18
作者
Mitra, A [1 ]
Elahi, MM [1 ]
Tariq, GB [1 ]
Mir, H [1 ]
Powell, R [1 ]
Spears, J [1 ]
机构
[1] Temple Univ, Div Plast & Reconstruct Surg, Philadelphia, PA 19122 USA
关键词
sternal closure; composite fixation; plating; sternal nonunion;
D O I
10.1097/01.sap.0000120316.11969.e0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Many techniques have been described to achieve closure of complicated median sternotomy wounds. The standard method of closure uses stainless steel wiring of the sternal halves; however, in complicated sternal closures, sternal cut-through and wire failure can occur. Recent literature advocates the use of fixation plates that achieve bony union, with plating across the median sternal osteotomy site as a singular method. We describe a technique of composite closure using titanium fixation plates to buttress the sternum in combination with circumferential stainless steel wires. This composite technique has been used in 6 patients with complicated sternal closures. Successful wound closure without complication was achieved in all cases. The technique and the clinical series with an illustrative example are presented. The use of plate and wire fixation represents an alternate method to conventional techniques to achieve sternal closure, stability, and uncomplicated wound healing in these difficult-to-manage cases.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 21 条
[1]   Fewer reoperations and shorter stay in the cardiac surgical ward when stabilising the sternum with the Ley prosthesis in post-operative mediastinitis [J].
Astudillo, R ;
Vaage, J ;
Myhre, U ;
Karevold, A ;
Gårdlund, B .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (01) :133-139
[2]   Is mediastinitis a preventable complication? A 10-year review [J].
Baskett, RJF ;
MacDougall, CE ;
Ross, DB .
ANNALS OF THORACIC SURGERY, 1999, 67 (02) :462-465
[3]   IMPROVED CHEST-WALL FIXATION FOR CORRECTION OF PECTUS EXCAVATUM [J].
BENTZ, ML ;
FUTRELL, JW .
BRITISH JOURNAL OF PLASTIC SURGERY, 1992, 45 (05) :367-370
[4]   Repair of transverse sternal nonunions using metal plates and autogenous bone graft [J].
Bertin, KC ;
Rice, RS ;
Doty, DB ;
Jones, KW .
ANNALS OF THORACIC SURGERY, 2002, 73 (05) :1661-1662
[5]   Mediastinitis after cardiovascular operations: A case-control study of risk factors [J].
Bitkover, CY ;
Gardlund, B .
ANNALS OF THORACIC SURGERY, 1998, 65 (01) :36-40
[6]   A PROSPECTIVE-STUDY OF STERNAL WOUND COMPLICATIONS [J].
BREYER, RH ;
MILLS, SA ;
HUDSPETH, AS ;
JOHNSTON, FR ;
CORDELL, AR .
ANNALS OF THORACIC SURGERY, 1984, 37 (05) :412-416
[7]  
Cohen DJ, 2002, ANN THORAC SURG, V73, P563
[8]   RECENT EXPERIENCE WITH MAJOR STERNAL WOUND COMPLICATIONS [J].
DEMMY, TL ;
PARK, SB ;
LIEBLER, GA ;
BURKHOLDER, JA ;
MAHER, TD ;
BENCKART, DH ;
MAGOVERN, GJ ;
MAGOVERN, GJ .
ANNALS OF THORACIC SURGERY, 1990, 49 (03) :458-462
[9]  
GOTTLIEB LJ, 1994, ARCH SURG-CHICAGO, V129, P489
[10]   Sternal plating for the treatment of sternal nonunion [J].
Hendrickson, SC ;
Koger, KE ;
Morea, CJ ;
Aponte, RL ;
Smith, PK ;
Levin, LS .
ANNALS OF THORACIC SURGERY, 1996, 62 (02) :512-518