The diagnostic value of magnetic resonance imaging and technetium 99m HMPAO single-photon-emission computed tomography for the diagnosis of Alzheimer disease in a community-dwelling elderly population

被引:44
|
作者
Scheltens, P
Launer, LJ
Barkhof, F
Weinstein, HC
Jonker, C
机构
[1] VRIJE UNIV AMSTERDAM, DEPT NEUROL, AMSTERDAM, NETHERLANDS
[2] VRIJE UNIV AMSTERDAM, DEPT PSYCHIAT, AMSTERDAM, NETHERLANDS
[3] VRIJE UNIV AMSTERDAM, DEPT DIAGNOST RADIOL, AMSTERDAM, NETHERLANDS
[4] ST LUCAS HOSP, DEPT NEUROL, AMSTERDAM, NETHERLANDS
[5] ERASMUS UNIV ROTTERDAM, SCH MED, DEPT EPIDEMIOL & BIOSTAT, NL-3000 DR ROTTERDAM, NETHERLANDS
关键词
single-photon-emission computed tomography; magnetic resonance imaging; mental functioning; medial temporal lobe atrophy; diagnostic value;
D O I
10.1097/00002093-199706000-00002
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of this study was to assess the diagnostic value for Alzheimer disease (AD) Of Single-photon-emission computed tomography (SPECT) and magnetic resonance imaging (MRI), separately and in combination. The study was part of a two-stage population-based study of mental functioning among noninstitutionalized 65- to 85-year-olds living in Amsterdam, The Netherlands. Participants (n = 51) were randomly selected within strata of cognitive function to obtain a sample of AD patients (n = 10) and clinically normal subjects (it = 41), of whom 22 displayed some cognitive impairment and fulfilled criteria for ''minimal dementia'' according to the Cambridge Examination for Mental Disorders of the Elderly. Coronal T1-weighted MRI was used to visualize the medial temporal lobe. Medial temporal lobe atrophy (MTA) was assessed qualitatively on a 0-4 scale. Regional cerebral blood flow on SPECT was assessed with the use of technetium 99m-HMPAO in three manually drawn regions of interest (frontal, parietal, and temporoparietal). Ratios were calculated by using the cerebellum as the reference area. MTA differed significantly between AD patients and clinically normal subjects (p = 0.0009), with a sensitivity for AD of 70% and a specificity of 76%. None of the three SPECT ratios differed between normal and AD subjects. The temporoparietal/cerebellar ratio had a sensitivity of 30% and a specificity of 71% at a cutoff of 0.76. When both tests were positive the combined sensitivity was low (20%), but the false-positive rate was also very low (5%). A negative result on MRI or any SPECT ratio yielded a high specificity (93-98%) but also a high false-negative rate (60-80%). Adding SPECT to MRI seems useful only if a diagnosis of AD is suspected clinically and confirmation is needed. When the clinical probability that AD is absent is high, normal results on either MRI or SPECT may confirm this notion. Given the fact that structural imaging should be performed in a clinical workup for dementia, using MRI only would be the most cost-effective approach.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [31] Diagnostic Performance of Noninvasive Myocardial Perfusion Imaging Using Single-Photon Emission Computed Tomography, Cardiac Magnetic Resonance, and Positron Emission Tomography Imaging for the Detection of Obstructive Coronary Artery Disease A Meta-Analysis
    Jaarsma, Caroline
    Leiner, Tim
    Bekkers, Sebastiaan C.
    Crijns, Harry J.
    Wildberger, Joachim E.
    Nagel, Eike
    Nelemans, Patricia J.
    Schalla, Simon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (19) : 1719 - 1728
  • [32] Acetazolamide-challenged perfusion magnetic resonance imaging for assessment of cerebrovascular reserve capacity in patients with symptomatic middle cerebral artery stenosis: comparison with technetium-99m-hexamethylpropyleneamine oxime single-photon emission computed tomography
    Kim, Hyun Jeong
    Kim, Tae Woo
    Ryu, Seon-Young
    Yang, Po Song
    Kwon, Min Jeong
    Kim, Ji Chang
    Lee, Yeon Soo
    Lee, Hyung Jin
    Yang, Ji Ho
    Kim, Jae Kyun
    Chung, Yong-An
    Oh, Eun-Young
    Lee, Sang Bong
    CLINICAL IMAGING, 2011, 35 (06) : 413 - 420
  • [33] Diagnostic accuracy of contrast echocardiography during adenosine stress for detection of abnormal myocardial perfusion: a prospective comparison with technetium-99 m sestamibi single-photon emission computed tomography
    Sahar S. Abdelmoneim
    Mathieu Bernier
    Abhijeet Dhoble
    Stuart Moir
    Mary E. Hagen
    Sue Ann C. Ness
    Patricia A. Pellikka
    Samir S. Abdel-Kader
    Sharon L. Mulvagh
    Heart and Vessels, 2010, 25 : 121 - 130
  • [34] A comparative study of pre-operative imaging methods in patients with primary hyperparathyroidism: Ultrasonography, 99mTc sestamibi, single photon emission computed tomography, and magnetic resonance imaging
    Akbaba, G.
    Berker, D.
    Isik, S.
    Aydin, Y.
    Ciliz, D.
    Peksoy, I.
    Ozuguz, U.
    Tutuncu, Y. A.
    Guler, S.
    JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2012, 35 (04) : 359 - 364
  • [35] Diagnostic accuracy of contrast echocardiography during adenosine stress for detection of abnormal myocardial perfusion: a prospective comparison with technetium-99 m sestamibi single-photon emission computed tomography
    Abdelmoneim, Sahar S.
    Bernier, Mathieu
    Dhoble, Abhijeet
    Moir, Stuart
    Hagen, Mary E.
    Ness, Sue Ann C.
    Pellikka, Patricia A.
    Abdel-Kader, Samir S.
    Mulvagh, Sharon L.
    HEART AND VESSELS, 2010, 25 (02) : 121 - 130
  • [36] The relationship between semiquantitative parameters derived from technetium-99m metoxyisobutylisonitrile dual-phase parathyroid single-photon emission computed tomography images and disease severity in primary hyperparathyroidism
    Cayir, Derya
    Araz, Mine
    Yalcindag, Ali
    Cakal, Erman
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (04) : 304 - 311
  • [37] A comparative study of pre-operative imaging methods in patients with primary hyperparathyroidism: Ultrasonography, 99mTc sestamibi, single photon emission computed tomography, and magnetic resonance imaging
    G. Akbaba
    D. Berker
    S. Isik
    Y. Aydin
    D. Ciliz
    I. Peksoy
    U. Ozuguz
    Y. A. Tutuncu
    S. Guler
    Journal of Endocrinological Investigation, 2012, 35 : 359 - 364
  • [38] Synthesis and biological evaluation of Tc-99m-cyclopentadienyltricarbonyl-technetium-labeled A-85380: An imaging probe for single-photon emission computed tomography investigation of nicotinic acetylcholine receptors in the brain
    Kimura, Hiroyuki
    Ueda, Masashi
    Kawashima, Hidekazu
    Arimitsu, Kenji
    Yagi, Yusuke
    Saji, Hideo
    BIOORGANIC & MEDICINAL CHEMISTRY, 2019, 27 (11) : 2245 - 2252
  • [39] TETRAHYDROAMINOACRIDINE MODULATES TC-99M LABELED ETHYLENE DICYSTEINATE RETENTION IN ALZHEIMERS-DISEASE MEASURED WITH SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IMAGING
    RIEKKINEN, P
    KUIKKA, J
    SOININEN, H
    HELKALA, EL
    HALLIKAINEN, M
    RIEKKINEN, P
    NEUROSCIENCE LETTERS, 1995, 195 (01) : 53 - 56
  • [40] DIAGNOSTIC EFFICACY OF STRESS TECHNETIUM-99M LABELED SESTAMIBI MYOCARDIAL PERFUSION SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN DETECTION OF CORONARY-ARTERY-DISEASE AMONG PATIENTS OVER AGE-80
    WANG, FP
    AMANULLAH, AM
    KIAT, H
    FRIEDMAN, JD
    BERMAN, DS
    JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (05) : 380 - 388