Prototype amperometric biosensor for sialic acid determination

被引:37
|
作者
Marzouk, Sayed A. M. [1 ]
Ashraf, S. S. [1 ]
Al Tayyari, Khawla A. [1 ]
机构
[1] United Arab Emirates Univ, Fac Sci, Dept Chem, Al Ain, U Arab Emirates
关键词
D O I
10.1021/ac061886d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the first report on the development, characterization, and applications of a prototype amperometric biosensor for free sialic acid (SA). The sensor was constructed by the coimmobilization of two enzymes, i.e., N-acetylneuraminic acid aldolase and pyruvate oxidase, on a polyester microporous membrane, which was then mounted on top of a platinum disk electrode. The SA biosensor operation was based on the sequential action of the two enzymes to ultimately produce hydrogen peroxide, which was then detected by anodic amperometry at the platinum electrode. The surface of the platinum electrode was coated with an electropolymeric layer to enhance the biosensor selectivity in the presence of interfering oxidizable species. Optimization of the enzyme layer composition resulted in a fast and steady current response in phosphate buffer pH 7.2 at 37 degrees C. The limit of detection was 10 mu M, and the response was linear to 3.5 mM (r = 0.9987). The prepared SA biosensors retained similar to 85% of their initial sensitivity after 8 days and showed excellent response reproducibility (CV = 2.3%). Utilization of a third enzyme, sialidase, expanded the scope of the present SA biosensor to determine bound sialic acid as well. The merits of the described biosensor allowed its successful application in determining SA in biological and pharmaceutical samples. The obtained results indicated that the presented SA biosensor should be a useful bioanalytical tool in several biological and clinical applications such as screening of SA as a nonspecific tumor marker as well as monitoring of tumor therapy.
引用
收藏
页码:1668 / 1674
页数:7
相关论文
共 50 条
  • [1] Flow injection determination of sialic acid based on amperometric detection
    Marzouk, Sayed A. M.
    Haddow, Jody D.
    Amin, Amr
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02) : 647 - 653
  • [2] Determination of uric acid in serum by a mediated amperometric biosensor
    Tsai, WC
    Wen, ST
    ANALYTICAL LETTERS, 2006, 39 (05) : 891 - 901
  • [3] An Amperometric Biosensor for the Determination of Lactic Acid During Malolactic Fermentation
    Sannini, Adriana
    Albanese, Donatella
    Malvano, Francesca
    Crescitelli, Alessio
    Di Matteo, Marisa
    FRUTIC ITALY 2015: 9TH NUT AND VEGETABLE PRODUCTION ENGINEERING SYMPOSIUM, 2015, 44 : 283 - 288
  • [4] Amperometric biosensor for the determination of creatine
    A. Ramanavicius
    Analytical and Bioanalytical Chemistry, 2007, 387 : 1899 - 1906
  • [5] Amperometric Biosensor for Phenol Determination
    da Costa Silva, Livia Maria
    Salgado, Andrea Medeiros
    Zarur Coelho, Maria Alice
    ICHEAP-10: 10TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-3, 2011, 24 : 1249 - +
  • [6] Amperometric biosensor for the determination of creatine
    Ramanavicius, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (05) : 1899 - 1906
  • [7] Rutin determination at an amperometric biosensor
    Mousty, Christine
    Cosnier, Serge
    Lopez, Marta Sanchez-Paniagua
    Lopez-Cabarcos, Enrique
    Lopez-Ruiz, Beatriz
    ELECTROANALYSIS, 2007, 19 (2-3) : 253 - 258
  • [8] Boron nitride nanosheet modified amperometric biosensor for uric acid determination
    Ondes, Baha
    Sunna, Cagdas
    Kilimci, Ulviye
    Uygun, Murat
    Uygun, Deniz Aktas
    MICROCHEMICAL JOURNAL, 2023, 194
  • [9] Ascorbic Acid Determination by an Amperometric Ascorbate Oxidase-based Biosensor
    Pisoschi, Aurelia-Magdalena
    Negulescu, Gheorghe-Petre
    Pisoschi, Aurel
    REVISTA DE CHIMIE, 2010, 61 (04): : 339 - 344
  • [10] Amperometric biosensor for rapid determination of alanine
    Kwan, RCH
    Hon, PYT
    Renneberg, R
    ANALYTICA CHIMICA ACTA, 2004, 523 (01) : 81 - 88