Metaphyseal Fixation Using Highly Porous Cones in Revision Total Knee Arthroplasty: Minimum Two Year Follow Up Study

被引:49
|
作者
Denehy, Kevin M. [1 ]
Abhari, Sarag [2 ]
Krebs, Viktor E. [3 ]
Higuera-Rueda, Carlos A. [4 ]
Samuel, Linsen T. [3 ]
Sultan, Assem A. [3 ]
Mont, Michael A. [5 ]
Malkani, Arthur L. [6 ]
机构
[1] Univ Louisville, Dept Orthopaed Surg, Louisville, KY 40202 USA
[2] Univ Louisville, Sch Med, Louisville, KY 40202 USA
[3] Cleveland Clin, Dept Orthopaed Surg, Cleveland, OH 44106 USA
[4] Cleveland Clin Florida, Dept Orthopaed Surg, Weston, FL USA
[5] Lenox Hill Hosp, Dept Orthopaed Surg, New York, NY 10021 USA
[6] Univ Louisville, KentuckyOne Hlth, Adult Reconstruct Program, 550 South Jackson St, Louisville, KY 40202 USA
来源
JOURNAL OF ARTHROPLASTY | 2019年 / 34卷 / 10期
关键词
revision TKA; metaphyseal cone; titanium; bone loss; failed TKA; TIBIAL BONE LOSS; STRUCTURAL ALLOGRAFT; TANTALUM CONES; DEFECTS; SLEEVES; RECONSTRUCTION; MANAGEMENT;
D O I
10.1016/j.arth.2019.03.045
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Highly porous metaphyseal cones have been introduced to restore metaphyseal integrity for improved cement interdigitation to achieve durable fixation in revision total knee arthroplasty (TKA). The purpose of this study is to review the survivorship, clinical results, and complications of revision TKA using highly porous 3-dimensionally printed titanium metaphyseal cones. Methods: This is a review of 62 revision TKAs using metaphyseal tibial cones, with 15 cases utilizing both tibial and femoral cones. The mean age of the patients was 66 years (range 32-84) who had a mean follow-up of 27 months (range 24-34). There were 38 women and 24 men, who had a mean body mass index of 33 (range 18.3-62). Results: Revision-free survival of the cones was 90.2%. If infection was excluded, survivorship was 100%. There were no cases of aseptic loosening. The mean Knee Society Score improved from 51 points preoperatively to 80 points at the time of latest follow-up. The mean Knee Society Functional Score improved from 48 points preoperatively to 68 points. A total of 15 of the 62 patients (24%) required additional surgery: 10 (16%) for infection, 3 (5%) for contracture, 1 for patellar subluxation, and 1 for quadriceps tendon rupture. Conclusion: Metaphyseal fixation is important for survivorship in revision TKA which can be challenging due to cancellous and structural bone loss encountered at the time of revision. Prosthetic joint infection continues to be the leading cause of failure in revision TKA. The use of highly porous titanium metaphyseal cones produced from 3-dimensionally printed technology used in this study demonstrated excellent short-term results with no cases of aseptic loosening. Further follow-up is required to determine if these results can be durable over a longer period. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:2439 / 2443
页数:5
相关论文
共 50 条
  • [31] Intermediate-Term Survivorship of Metaphyseal Cones and Sleeves in Revision Total Knee Arthroplasty
    Small, Ilan
    Meghpara, Michael
    Stein, Jonah
    Goh, Graham S.
    Banerjee, Samik
    Courtney, P. Maxwell
    JOURNAL OF ARTHROPLASTY, 2022, 37 (09): : 1839 - 1843
  • [32] Use of Cementless Metaphyseal Fixation in Revision Total Knee Arthroplasty in the United States
    Carender, Christopher N.
    An, Qiang
    Tetreault, Matthew W.
    De, Ayushmita
    Brown, Timothy S.
    Bedard, Nicholas A.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (03): : 554 - 558
  • [33] Revision total knee arthroplasty using the Kinemax Plus Superstabilizer prosthesis: Minimum 10-year follow-up
    Harwin, SF
    KNEE, 2006, 13 (02): : 93 - 97
  • [34] Clinical Outcomes Following Revision Total Knee Arthroplasty: Minimum 2-Year Follow-up
    Quinn, Jonathan
    Jones, Peter
    Randle, Ray
    CLINICS IN ORTHOPEDIC SURGERY, 2022, 14 (01) : 69 - 75
  • [35] Minimum 6-Year Follow-Up of Revision Total Knee Arthroplasty Without Patella Reimplantation
    Dalury, David F.
    Adams, Mary Jo
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 91 - 94
  • [36] Cementless Total Knee Arthroplasty Using a Highly Porous Tibial Baseplate in Morbidly Obese Patients: Minimum 5-Year Follow-Up
    King, Bradley A.
    Miller, Adam J.
    Nadar, Arun C.
    Smith, Langan S.
    Yakkanti, Madhusudhan R.
    Harwin, Steven F.
    Malkani, Arthur L.
    JOURNAL OF KNEE SURGERY, 2023, 36 (09) : 995 - 1000
  • [37] Revision total knee arthroplasty with porous-coated metaphyseal sleeves provides radiographic ingrowth and stable fixation
    Fedorka, Catherine J.
    Chen, Antonia F.
    Pagnotto, Michael R.
    Crossett, Lawrence S.
    Klatt, Brian A.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (05) : 1500 - 1505
  • [38] Revision total knee arthroplasty with porous-coated metaphyseal sleeves provides radiographic ingrowth and stable fixation
    Catherine J. Fedorka
    Antonia F. Chen
    Michael R. Pagnotto
    Lawrence S. Crossett
    Brian A. Klatt
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 1500 - 1505
  • [39] Osteointegrative Sleeves for Metaphyseal Defect Augmentation in Revision Total Knee Arthroplasty: Clinical and Radiological 5-Year Follow-Up
    Wirries, Nils
    Winnecken, Hans Joerg
    von Lewinski, Gabriela
    Windhagen, Henning
    Skutek, Michael
    JOURNAL OF ARTHROPLASTY, 2019, 34 (09): : 2022 - 2029
  • [40] Survivorship and Radiographic Evaluation of Metaphyseal Cones With Short Cemented Stems in Revision Total Knee Arthroplasty
    Behery, Omar A.
    Shing, Elaine Z.
    Yu, Ziqing
    Springer, Bryan D.
    Fehring, Thomas K.
    Otero, Jesse E.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (02): : 330 - 335