Metaphyseal Fixation Using Highly Porous Cones in Revision Total Knee Arthroplasty: Minimum Two Year Follow Up Study

被引:49
|
作者
Denehy, Kevin M. [1 ]
Abhari, Sarag [2 ]
Krebs, Viktor E. [3 ]
Higuera-Rueda, Carlos A. [4 ]
Samuel, Linsen T. [3 ]
Sultan, Assem A. [3 ]
Mont, Michael A. [5 ]
Malkani, Arthur L. [6 ]
机构
[1] Univ Louisville, Dept Orthopaed Surg, Louisville, KY 40202 USA
[2] Univ Louisville, Sch Med, Louisville, KY 40202 USA
[3] Cleveland Clin, Dept Orthopaed Surg, Cleveland, OH 44106 USA
[4] Cleveland Clin Florida, Dept Orthopaed Surg, Weston, FL USA
[5] Lenox Hill Hosp, Dept Orthopaed Surg, New York, NY 10021 USA
[6] Univ Louisville, KentuckyOne Hlth, Adult Reconstruct Program, 550 South Jackson St, Louisville, KY 40202 USA
关键词
revision TKA; metaphyseal cone; titanium; bone loss; failed TKA; TIBIAL BONE LOSS; STRUCTURAL ALLOGRAFT; TANTALUM CONES; DEFECTS; SLEEVES; RECONSTRUCTION; MANAGEMENT;
D O I
10.1016/j.arth.2019.03.045
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Highly porous metaphyseal cones have been introduced to restore metaphyseal integrity for improved cement interdigitation to achieve durable fixation in revision total knee arthroplasty (TKA). The purpose of this study is to review the survivorship, clinical results, and complications of revision TKA using highly porous 3-dimensionally printed titanium metaphyseal cones. Methods: This is a review of 62 revision TKAs using metaphyseal tibial cones, with 15 cases utilizing both tibial and femoral cones. The mean age of the patients was 66 years (range 32-84) who had a mean follow-up of 27 months (range 24-34). There were 38 women and 24 men, who had a mean body mass index of 33 (range 18.3-62). Results: Revision-free survival of the cones was 90.2%. If infection was excluded, survivorship was 100%. There were no cases of aseptic loosening. The mean Knee Society Score improved from 51 points preoperatively to 80 points at the time of latest follow-up. The mean Knee Society Functional Score improved from 48 points preoperatively to 68 points. A total of 15 of the 62 patients (24%) required additional surgery: 10 (16%) for infection, 3 (5%) for contracture, 1 for patellar subluxation, and 1 for quadriceps tendon rupture. Conclusion: Metaphyseal fixation is important for survivorship in revision TKA which can be challenging due to cancellous and structural bone loss encountered at the time of revision. Prosthetic joint infection continues to be the leading cause of failure in revision TKA. The use of highly porous titanium metaphyseal cones produced from 3-dimensionally printed technology used in this study demonstrated excellent short-term results with no cases of aseptic loosening. Further follow-up is required to determine if these results can be durable over a longer period. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:2439 / 2443
页数:5
相关论文
共 50 条
  • [31] Total knee arthroplasty revision with trabecular tantalum cones: Preliminary retrospective study of 51 patients from two centres with a minimal 2-year follow-up
    Girerd, D.
    Parratte, S.
    Lunebourg, A.
    Boureau, F.
    Ollivier, M.
    Pasquier, G.
    Putman, S.
    Migaud, H.
    Argenson, J. N.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (04) : 429 - 433
  • [32] 3D-printed titanium metaphyseal cones in revision total knee arthroplasty with cemented and cementless stems
    Anderson, L. A.
    Christie, M.
    Blackburn, B. E.
    Mahan, C.
    Earl, C.
    Pelt, C. E.
    Peters, C. L.
    Gililland, J.
    BONE & JOINT JOURNAL, 2021, 103B (06) : 150 - 157
  • [33] Osteointegrative Sleeves for Metaphyseal Defect Augmentation in Revision Total Knee Arthroplasty: Clinical and Radiological 5-Year Follow-Up
    Wirries, Nils
    Winnecken, Hans Joerg
    von Lewinski, Gabriela
    Windhagen, Henning
    Skutek, Michael
    JOURNAL OF ARTHROPLASTY, 2019, 34 (09) : 2022 - 2029
  • [34] Porous-coated metaphyseal sleeves and MBT implant for severe bone loss in revision total knee arthroplasty: a mean 2.4-year follow-up
    Wu, Yushun
    Feng, Eryou
    Zhang, Yiyuan
    Lin, Feitai
    Lin, Liqiong
    Li, Zhanglai
    Xiao, Lili
    ARTHROPLASTY, 2020, 2 (01)
  • [35] Excellent two-year survivorship of 3D-printed metaphyseal cones in revision total knee arthroplasty A RELIABLE AND SAFE REAMER-BASED SYSTEM
    Tetreault, M. W.
    Pero, K., I
    Pagnano, M. W.
    Hanssen, A. D.
    Abdel, M. P.
    BONE & JOINT JOURNAL, 2020, 102B (06) : 107 - 115
  • [36] Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study
    Kim, Han Soul
    Kim, Ji Wan
    Chang, Jae Suk
    Kim, Chul-Ho
    MEDICINA-LITHUANIA, 2023, 59 (06):
  • [37] Midterm Results of Porous Tantalum Femoral Cones in Revision Total Knee Arthroplasty
    Potter, G. David, III
    Abdel, Matthew P.
    Lewallen, David G.
    Hanssen, Arlen D.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (15) : 1286 - 1291
  • [38] Short-Term Survivorship of 3D-Printed Titanium Metaphyseal Cones in Revision Total Knee Arthroplasty: A Systematic Review
    Mancino, Fabio
    Di Matteo, Vincenzo
    Mocini, Fabrizio
    Pietramala, Silvia
    Singlitico, Alessandro
    De Fazio, Andrea
    La Vergata, Vincenzo
    Gasparini, Giorgio
    Maccauro, Giulio
    De Martino, Ivan
    ORTHOPEDIC REVIEWS, 2022, 14 (05)
  • [39] Minimum 6-Year Follow-Up of Revision Total Knee Arthroplasty Without Patella Reimplantation
    Dalury, David F.
    Adams, Mary Jo
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08) : 91 - 94
  • [40] Revision total knee arthroplasty using the Kinemax Plus Superstabilizer prosthesis: Minimum 10-year follow-up
    Harwin, SF
    KNEE, 2006, 13 (02) : 93 - 97