Development of an Evaluation System for Magnetic Resonance Imaging Based Three-Dimensional Modeling of a Transfemoral Prosthetic Socket Using Finite Elements

被引:3
作者
Jamaludin, Mohd Syahmi [1 ]
Hanafusa, Akihiko [1 ]
Shinichirou, Yamamoto [1 ]
Agarie, Yukio [2 ]
Otsuka, Hiroshi [3 ]
Ohnishi, Kengo [4 ]
机构
[1] Shibaura Inst Technol, Dept Biosci & Engn, Tokyo 1358548, Japan
[2] Niigata Univ Hlth & Welf, Dept Supporting Prosthet Orthot, Niigata 9503102, Japan
[3] Univ Human Arts & Sci, Dept Prosthet & Orthot, Saitama 3398539, Japan
[4] Tokyo Denki Univ, Dept Sci & Engn, Tokyo 1208551, Japan
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 18期
关键词
prosthetic socket; finite element method; finite element analysis; transfemoral residuum; biomechanics; bipedal stances; 3D model; RESIDUAL LIMB; TRANSTIBIAL RESIDUUM; CONTACT INTERFACE; VOLUME CHANGE;
D O I
10.3390/app9183662
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Recent technologies have suggested the utilization of three-dimensional (3D) printing technology to enhance the fabrication accuracy of prosthetics. Accordingly, simulations are used to obtain precise parameters for subject-specified prosthetic socket. This study proposes an evaluation system to measure the accuracy of a subject-specific 3D transfemoral residuum model during the interaction with the socket in conjunction with the application of finite element methods. The proposed system can be used in future validations of socket fabrication. The evaluation is based on the measurement of the residuum's soft tissue deformation inside two types of prosthetic sockets. In comparison with other studies, the 3D models were constructed with magnetic resonance images (MRI) with the aid of computer-aided design (CAD) software. The measurement of soft tissue deformation was conducted based on the measurement of the volumetric value of fat, muscle and skin in the pre- and post-donning phases. The result yielded a promising correlation coefficient value between the simulation and the experiment in the soft tissue deformation evaluation. The relation of the muscle-fat ratio in the residuum is extremely important in the determination of the ability of the prosthetic to deform. The environment during the socket fitting session was similar to that defined by the set boundary conditions in simulations. In view of the promising results of this study, the evaluation system proposed herein is considered reliable and is envisaged to be used in future research.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Three-Dimensional Morphometry of Single Endothelial Cells with Substrate Stretching and Image-Based Finite Element Modeling
    Hiroshi Yamada
    Norihide Mouri
    Shinji Nobuhara
    EURASIP Journal on Advances in Signal Processing, 2010
  • [42] Comparison of five different fixation techniques of sagittal split ramus osteotomy using three-dimensional finite elements analysis
    Sato, F. R. L.
    Asprino, L.
    Noritomi, P. Y.
    da Silva, J. V. L.
    de Moraes, M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (08) : 934 - 941
  • [43] Three-Dimensional MT Conductive Anisotropic and Magnetic Modeling Using A - φ Potentials Employing a Mixed Nodal and Edge-Based Element Method
    Zhou, Zongyi
    Yi, Mingkuan
    Zhou, Junjun
    Cheng, Lianzheng
    Song, Tao
    Gong, Chunye
    Yang, Bo
    Xiao, Tiaojie
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [44] Three-Dimensional Finite Element Method Modeling for the Improvement of the Design of an Electromechanical Device to Drive a Fan Shaft Balancing System
    Lefik, Marcin
    Krygier, Michal
    Podsedkowski, Leszek
    ENERGIES, 2025, 18 (01)
  • [45] Development of anatomically based customizable three-dimensional finite-element model of pelvic floor support system: POP-SIM1.0
    Gordon, Mark T.
    DeLancey, John O. L.
    Renfroe, Aaron
    Battles, Andrew
    Chen, Luyun
    INTERFACE FOCUS, 2019, 9 (04)
  • [46] Accuracy of three-dimensional finite element modeling using two different dental cone beam computed tomography systems
    Hasegawa, Aki
    Shinya, Akikazu
    Lassila, Lippo V. J.
    Yokoyama, Daiichiro
    Nakasone, Yuji
    Vallittu, Pekka K.
    Shinya, Akiyoshi
    ODONTOLOGY, 2013, 101 (02) : 210 - 215
  • [47] Accuracy of three-dimensional finite element modeling using two different dental cone beam computed tomography systems
    Aki Hasegawa
    Akikazu Shinya
    Lippo V. J. Lassila
    Daiichiro Yokoyama
    Yuji Nakasone
    Pekka K. Vallittu
    Akiyoshi Shinya
    Odontology, 2013, 101 : 210 - 215
  • [48] Confocal and force probe imaging system for simultaneous three-dimensional optical and mechanical spectroscopic evaluation of biological samples
    Lin, Feilong
    Elliott, Kevin E.
    Parker, Wes
    Chakraborty, Nilay
    Teo, Chek Sing
    Smith, Stuart T.
    Elliott, Gloria D.
    Moyer, Patrick J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (05)
  • [49] A new quantitative evaluation system for distal radioulnar joint instability using a three-dimensional electromagnetic sensor
    Mukohara, Shintaro
    Mifune, Yutaka
    Inui, Atsuyuki
    Nishimoto, Hanako
    Kurosawa, Takashi
    Yamaura, Kohei
    Yoshikawa, Tomoya
    Shinohara, Issei
    Hoshino, Yuichi
    Nagamune, Kouki
    Kuroda, Ryosuke
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [50] Three-dimensional modeling of moisture transport in wood using near-infrared hyperspectral imaging and X-ray computed tomography in conjunction with finite element analysis
    Wenpeng Zeng
    Takaaki Fujimoto
    Tetsuya Inagaki
    Satoru Tsuchikawa
    Te Ma
    Journal of Wood Science, 70