Development of an Evaluation System for Magnetic Resonance Imaging Based Three-Dimensional Modeling of a Transfemoral Prosthetic Socket Using Finite Elements

被引:3
作者
Jamaludin, Mohd Syahmi [1 ]
Hanafusa, Akihiko [1 ]
Shinichirou, Yamamoto [1 ]
Agarie, Yukio [2 ]
Otsuka, Hiroshi [3 ]
Ohnishi, Kengo [4 ]
机构
[1] Shibaura Inst Technol, Dept Biosci & Engn, Tokyo 1358548, Japan
[2] Niigata Univ Hlth & Welf, Dept Supporting Prosthet Orthot, Niigata 9503102, Japan
[3] Univ Human Arts & Sci, Dept Prosthet & Orthot, Saitama 3398539, Japan
[4] Tokyo Denki Univ, Dept Sci & Engn, Tokyo 1208551, Japan
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 18期
关键词
prosthetic socket; finite element method; finite element analysis; transfemoral residuum; biomechanics; bipedal stances; 3D model; RESIDUAL LIMB; TRANSTIBIAL RESIDUUM; CONTACT INTERFACE; VOLUME CHANGE;
D O I
10.3390/app9183662
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Recent technologies have suggested the utilization of three-dimensional (3D) printing technology to enhance the fabrication accuracy of prosthetics. Accordingly, simulations are used to obtain precise parameters for subject-specified prosthetic socket. This study proposes an evaluation system to measure the accuracy of a subject-specific 3D transfemoral residuum model during the interaction with the socket in conjunction with the application of finite element methods. The proposed system can be used in future validations of socket fabrication. The evaluation is based on the measurement of the residuum's soft tissue deformation inside two types of prosthetic sockets. In comparison with other studies, the 3D models were constructed with magnetic resonance images (MRI) with the aid of computer-aided design (CAD) software. The measurement of soft tissue deformation was conducted based on the measurement of the volumetric value of fat, muscle and skin in the pre- and post-donning phases. The result yielded a promising correlation coefficient value between the simulation and the experiment in the soft tissue deformation evaluation. The relation of the muscle-fat ratio in the residuum is extremely important in the determination of the ability of the prosthetic to deform. The environment during the socket fitting session was similar to that defined by the set boundary conditions in simulations. In view of the promising results of this study, the evaluation system proposed herein is considered reliable and is envisaged to be used in future research.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Evaluation of the wall deflections of a deep excavation in Central Jakarta using three-dimensional modeling
    Hsiung, Bin-Chen Benson
    Yang, Kuo-Hsin
    Aila, Wahyuning
    Ge, Louis
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 72 : 84 - 96
  • [32] Design and evaluation of a new three-dimensional motion capture system based on video
    Castro, J. L. Garrido
    Medina-Carnicer, R.
    Galisteo, Alfonso Martinez
    GAIT & POSTURE, 2006, 24 (01) : 126 - 129
  • [33] Internal Three-Dimensional Strains in Human Intervertebral Discs Under Axial Compression Quantified Noninvasively by Magnetic Resonance Imaging and Image Registration
    Yoder, Jonathon H.
    Peloquin, John M.
    Song, Gang
    Tustison, Nick J.
    Moon, Sung M.
    Wright, Alexander C.
    Vresilovic, Edward J.
    Gee, James C.
    Elliott, Dawn M.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (11):
  • [34] Roll pass evaluation for three-dimensional section rolling using a simplified finite element method
    Wen, SW
    Hartley, P
    Pillinger, I
    Sturgess, CEN
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 1997, 211 (02) : 143 - 158
  • [35] Patellar calcar: morphometric analysis by knee magnetic resonance imaging and three-dimensional reconstruction software-assisted
    Benavente, Sergio
    Villagra, Joaquin
    SURGICAL AND RADIOLOGIC ANATOMY, 2019, 41 (12) : 1483 - 1488
  • [36] Stress Distribution in Single Dental Implant System: Three-Dimensional Finite Element Analysis Based on an In Vitro Experimental Model
    Edwards Rezende, Carlos Eduardo
    Chase-Diaz, Melody
    Costa, Max Doria
    Albarracin, Max Laurent
    Paschoeto, Gabriela
    Capello Sousa, Edson Antonio
    Rubo, Jose Henrique
    Sanches Borges, Ana Flavia
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (07) : 2196 - 2200
  • [37] Heterogeneous biomechanical/mathematical modeling of spatial prediction of glioblastoma progression using magnetic resonance imaging-based finite element method
    Ghahramani, Mohammad Reza
    Bavi, Omid
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 257
  • [38] Three-dimensional magnetic field analyses on the magnetron sputtering system by using Free Mesh Method
    Ido, S
    Hirose, R
    COMPUTER PHYSICS COMMUNICATIONS, 2001, 142 (1-3) : 338 - 342
  • [39] Nonlinear three-dimensional magnetic field computations using lagrange finite-element functions and algebraic multigrid
    Kaltenbacher, M
    Reitzinger, S
    IEEE TRANSACTIONS ON MAGNETICS, 2002, 38 (03) : 1489 - 1496
  • [40] Development of Galerkin Finite Element Method Three-dimensional Computational Code for the Multigroup Neutron Diffusion Equation with Unstructured Tetrahedron Elements
    Hosseini, Seyed Abolfazl