Development of an Evaluation System for Magnetic Resonance Imaging Based Three-Dimensional Modeling of a Transfemoral Prosthetic Socket Using Finite Elements

被引:3
|
作者
Jamaludin, Mohd Syahmi [1 ]
Hanafusa, Akihiko [1 ]
Shinichirou, Yamamoto [1 ]
Agarie, Yukio [2 ]
Otsuka, Hiroshi [3 ]
Ohnishi, Kengo [4 ]
机构
[1] Shibaura Inst Technol, Dept Biosci & Engn, Tokyo 1358548, Japan
[2] Niigata Univ Hlth & Welf, Dept Supporting Prosthet Orthot, Niigata 9503102, Japan
[3] Univ Human Arts & Sci, Dept Prosthet & Orthot, Saitama 3398539, Japan
[4] Tokyo Denki Univ, Dept Sci & Engn, Tokyo 1208551, Japan
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 18期
关键词
prosthetic socket; finite element method; finite element analysis; transfemoral residuum; biomechanics; bipedal stances; 3D model; RESIDUAL LIMB; TRANSTIBIAL RESIDUUM; CONTACT INTERFACE; VOLUME CHANGE;
D O I
10.3390/app9183662
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Recent technologies have suggested the utilization of three-dimensional (3D) printing technology to enhance the fabrication accuracy of prosthetics. Accordingly, simulations are used to obtain precise parameters for subject-specified prosthetic socket. This study proposes an evaluation system to measure the accuracy of a subject-specific 3D transfemoral residuum model during the interaction with the socket in conjunction with the application of finite element methods. The proposed system can be used in future validations of socket fabrication. The evaluation is based on the measurement of the residuum's soft tissue deformation inside two types of prosthetic sockets. In comparison with other studies, the 3D models were constructed with magnetic resonance images (MRI) with the aid of computer-aided design (CAD) software. The measurement of soft tissue deformation was conducted based on the measurement of the volumetric value of fat, muscle and skin in the pre- and post-donning phases. The result yielded a promising correlation coefficient value between the simulation and the experiment in the soft tissue deformation evaluation. The relation of the muscle-fat ratio in the residuum is extremely important in the determination of the ability of the prosthetic to deform. The environment during the socket fitting session was similar to that defined by the set boundary conditions in simulations. In view of the promising results of this study, the evaluation system proposed herein is considered reliable and is envisaged to be used in future research.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] A three-dimensional finite element model of the transibial residual limb and prosthetic socket to predict skin temperatures
    Peery, Jeffrey T.
    Klute, Glenn K.
    Blevins, Joanna J.
    Ledoux, William R.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2006, 14 (03) : 336 - 343
  • [2] A Three-Dimensional Finite Element Model Constructed Using Magnetic Resonance Images of a Knee
    Zhan, Sheng-Liang
    Xia, Jing
    Guo, Tong-Tong
    PROCEEDINGS OF THE 3RD ANNUAL INTERNATIONAL CONFERENCE ON MECHANICS AND MECHANICAL ENGINEERING (MME 2016), 2017, 105 : 1015 - 1021
  • [3] Magnetic resonance imaging for in vivo assessment of three-dimensional patellar tracking
    Fellows, RA
    Hill, NA
    Gill, HS
    MacIntyre, NJ
    Harrison, MM
    Ellis, RE
    Wilson, DR
    JOURNAL OF BIOMECHANICS, 2005, 38 (08) : 1643 - 1652
  • [4] Platform Switching: Biomechanical Evaluation Using Three-Dimensional Finite Element Analysis
    Tabata, Lucas Fernando
    Rocha, Eduardo Passos
    Ricardo Barao, Valentim Adelino
    Assuncao, Wirley Goncalves
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (03) : 482 - 491
  • [5] A systematic development of EAS three-dimensional finite elements for the alleviation of locking phenomena
    Caseiro, J. F.
    Alves de Sousa, R. J.
    Valente, R. A. F.
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2013, 73 : 30 - 41
  • [6] Evaluation of the short-term curative effect of closed reduction in the treatment of developmental dysplasia of the hip based on three-dimensional magnetic resonance imaging finite element analysis
    Liu, Jiani
    Gao, Tianyang
    Li, Jia
    Shan, Hui
    Pan, Shinong
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [7] Evaluation of the short-term curative effect of closed reduction in the treatment of developmental dysplasia of the hip based on three-dimensional magnetic resonance imaging finite element analysis
    Jiani Liu
    Tianyang Gao
    Jia Li
    Hui Shan
    Shinong Pan
    BMC Musculoskeletal Disorders, 23
  • [8] Three-dimensional biomechanical properties of the human rectum evaluated with magnetic resonance imaging
    Frokjær, JB
    Liao, D
    Bergmann, A
    McMahon, BP
    Steffensen, E
    Drewes, AM
    Gregersen, H
    NEUROGASTROENTEROLOGY AND MOTILITY, 2005, 17 (04) : 531 - 540
  • [9] Magnetic-resonance-imaging-based three-dimensional muscle reconstruction of hip abductor muscle volume in a person with a transfemoral bone-anchored prosthesis: A feasibility study
    Leijendekkers, Ruud A.
    Marra, Marco A.
    Ploegmakers, Marieke J. M.
    Van Hinte, Gerben
    Frolke, Jan Paul
    Van De Meent, Hendrik
    Staal, J. Bart
    Hoogeboom, Thomas J.
    Verdonschot, Nico
    PHYSIOTHERAPY THEORY AND PRACTICE, 2019, 35 (05) : 495 - 504
  • [10] Three dimensional finite elements modeling of FGM plate bending using UMAT
    Messaoudi, Khalid
    Boukhalfa, Abdelkrim
    Beldjelili, Youcef
    STRUCTURAL ENGINEERING AND MECHANICS, 2018, 66 (04) : 487 - 494