Effective dose to staff from interventional procedures: estimations from single and double dosimetry

被引:14
作者
Kuipers, Gerritjan [1 ]
Velders, Xandra L. [1 ]
机构
[1] Acad Med Ctr, NL-1100 DD Amsterdam, Netherlands
关键词
CARDIAC-CATHETERIZATION; FOLLOW-UP; RADIOLOGY;
D O I
10.1093/rpd/ncp155
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The exposure of 11 physicians performing interventional procedures was measured by means of two personal dosemeters. One personal dosemeter was worn outside the lead apron and an additional under the lead apron. The study was set up in order to determine the added value of a dosemeter worn under the lead apron. With the doses measured, the effective doses of the physicians were estimated using an algorithm for single dosimetry and two algorithms for double dosimetry. The effective doses calculated with the single dosimetry algorithm ranged from 0.11 to 0.85 mSv in 4 weeks. With the double dosimetry algorithms, the effective doses ranged from 0.02 mSv to 0.47 mSv. The statistical analysis revealed no significant differences in the accuracy of the effective doses calculated with single or double dosimetry algorithms. It was concluded that the effective dose cannot be considered a more accurate estimate when two dosemeters are used instead of one.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 14 条
  • [1] [Anonymous], 2002, 6 EUR ALARA NETW WOR
  • [2] Double-dosimetry algorithm for workers in interventional radiology
    Clerinx, Peter
    Buls, N.
    Bosmans, H.
    de Mey, J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 321 - 327
  • [3] DIJK JWE, 1996, RADIAT PROT DOSIM, V66, P17
  • [4] *INT COMM RAD PROT, 2000, PUBL INT COMM RAD PR, V85
  • [5] Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff
    Jarvinen, H.
    Buls, N.
    Clerinx, P.
    Jansen, J.
    Miljanic, S.
    Nikodemova, D.
    Ranogajec-Komor, M.
    d'Errico, F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 333 - 339
  • [6] Evaluation of the occupational doses of interventional radiologists
    Kuipers, Gerritjan
    Velders, Xandra L.
    de Winter, Robbert J.
    Reekers, Jim A.
    Piek, Jan J.
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 31 (03) : 483 - 489
  • [7] Phantom-derived estimation of effective dose equivalent from x rays with and without a lead apron
    Mateya, CF
    Claycamp, HG
    [J]. HEALTH PHYSICS, 1997, 72 (06): : 842 - 847
  • [8] National Council on Radiation Protection and Measurements, 1995, 122 NAT COUNC RAD PR
  • [9] Netherlands Commission on Radiation Dosimetry, 2008, 19 NETH COMM RAD DOS
  • [10] THE ESTIMATION OF OCCUPATIONAL EFFECTIVE DOSE IN DIAGNOSTIC-RADIOLOGY WITH 2 DOSIMETERS
    NIKLASON, LT
    MARX, MV
    CHAN, HP
    [J]. HEALTH PHYSICS, 1994, 67 (06): : 611 - 615