Experimental study on the seismic performance of composite columns with an ultra-high-strength concrete-filled steel tube core

被引:13
|
作者
Yang, Yong [1 ]
Du, Xing [1 ]
Yu, Yunlong [1 ,2 ]
Pan, Yongpu [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, 13 Yanta Rd, Xian 710055, Shaanxi, Peoples R China
[2] Key Lab Struct & Earthquake Resistance, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
bearing capacity; experimental study; prestressed steel strips; reinforced concrete column with concrete-filled steel tube core; seismic performance; ENCASED CFST COLUMNS; COMBINED COMPRESSION;
D O I
10.1177/1369433219879805
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The ultra-high-strength concrete-encased concrete-filled steel tube column consists of a concrete-filled steel tube core and a rectangle-shaped reinforced concrete encasement. This article presents the seismic performance analysis of ultra-high-strength concrete-encased concrete-filled steel tube columns subjected to cyclic loading. Based on the measured load-lateral displacement hysteresis curves of six ultra-high-strength concrete-encased concrete-filled steel tube columns and two conventional RC columns, the seismic behaviours, such as the ductility, energy dissipation, stiffness and load-bearing capacity, were analysed. The effects of the arrangement of the stirrups and the layout of the prestressed steel strips on the seismic performance of the composite columns were critically examined. The test results indicated that the ductility and energy dissipation performance of the ultra-high-strength concrete-encased concrete-filled steel tube columns were increased by 74.8% and 162.7%, respectively, compared with the conventional columns. The configuration of the prestressed steel strip increased the ductility of the composite column by 28.9%-63% and increased the energy consumption performance by 160.2%-263.3%. By reducing the stirrup spacing and using prestressed steel strips, the concrete-filled steel tube core columns could be effectively confined, leading to a great enhancement in ductility, energy dissipation, stiffness and load-bearing capacity.
引用
收藏
页码:794 / 809
页数:16
相关论文
共 50 条
  • [1] Experimental study on seismic behavior of square spiral-confined ultra-high-strength concrete-filled steel tube columns
    Chen Z.
    Hu H.
    Xu L.
    Wang H.
    Zhang B.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 : 288 - 294
  • [2] Experimental study on seismic behavior of high-strength concrete-filled steel tube composite columns
    Qian, Jiaru
    Kang, Hongzhen
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (04): : 85 - 93
  • [3] Seismic performance of three-directional prestressed columns with a high strength concrete-filled steel tube core: An experimental study
    Yang Y.
    Feng T.
    Ma X.
    Ye J.
    Li Y.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2018, 39 (03): : 461 - 470
  • [4] Experimental study on seismic damage behavior of high strength concrete-encased concrete-filled steel tube composite columns
    Ke X.
    Yang L.
    An J.
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2020, 48 (08): : 13 - 19
  • [5] Seismic performance of concrete-filled steel tube columns using ultra-high-strength steel under long-period ground motion demands
    Hayashi, Kazuhiro
    Inamasu, Hiroyuki
    ADVANCES IN STRUCTURAL ENGINEERING, 2023, 26 (12) : 2160 - 2171
  • [6] Seismic performance of concrete-filled steel tubular composite columns with ultra high performance concrete plates
    Wei, Jiangang
    Ying, Haodong
    Yang, Yan
    Zhang, Wei
    Yuan, Huihui
    Zhou, Jun
    ENGINEERING STRUCTURES, 2023, 278
  • [7] Experimental study on compressive bearing capacity of high strength concrete-filled steel tube composite columns
    Kang, Hongzhen
    Yao, Lei
    Song, Ximin
    Ye, Yinghua
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 410 - +
  • [8] An Experimental Study on the Behavior of Square Concrete-Filled High Strength Steel Tube Columns
    Hyung-suk Jung
    Chang-sik Choi
    Journal of Iron and Steel Research(International), 2011, 18 (S1) : 878 - 882
  • [9] An Experimental Study on the Behavior of Square Concrete-Filled High Strength Steel Tube Columns
    Jung, Hyung-suk
    Choi, Chang-sik
    JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL, 2011, 18 : 878 - 882
  • [10] Seismic performance of composite jacket-confined square high-strength concrete-filled steel tube columns
    Xu, Li
    Hu, Hong-Song
    Peng, Biao
    Guo, Zi-Xiong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 211