Collimator blurring reduction method using fine angular sampling projection data in SPECT

被引:0
作者
Motomura, N [1 ]
Nambu, K [1 ]
Kojima, A [1 ]
Tomiguchi, S [1 ]
Ogawa, K [1 ]
机构
[1] Med Syst Res & Dev Dept, Otawara, Tochigi 3248550, Japan
来源
2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4 | 2002年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to collimator aperture, spatial resolution of SPECT data varies with source-to-detector distance. Since radius of detector rotation is bigger when scanning larger patients, spatial resolution is degraded in these cases. Emitted gamma rays travel not only along the central axis of the collimator hole but also off-axis due to collimator aperture. However, an off-axis my at one angle would be a central-axis ray at another angle; therefore, raw projection data at one angle can be thought of as an ensemble of central-axis rays collected from a small arc equal to collimator aperture. Thus, fine angular sampling can compensate for collimator blurring. By using sampling pitch of less than half the collimator aperture angle, compensation was performed by subtracting the weighted sum of the projection data from the raw projection data. Collimator geometry and detector rotation radius determined the weighting function. Cylindrical phantom with four different-sized rods and torso phantom for Tl-201 cardiac SPECT simulation were used for evaluation. Aperture angle of the collimator was 7 degrees. Projection sampling pitch was 2 degrees. In both phantom studies, the proposed method showed improvement in contrast and reduction of partial volume effect, thereby indicating that the proposed method can compensate adequately for image blurring caused by collimator aperture.
引用
收藏
页码:2139 / 2142
页数:4
相关论文
共 12 条
[1]  
Edholm P. R., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V671, P8, DOI 10.1117/12.966672
[2]   RESTORATION OF GAMMA CAMERA-BASED NUCLEAR-MEDICINE IMAGES [J].
HON, TC ;
RANGAYYAN, RM ;
HAHN, LJ ;
KLOIBER, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (04) :354-363
[3]   OPTIMAL PREPROCESSING BUTTERWORTH-WIENER FILTER FOR TL-201 MYOCARDIAL SPECT [J].
HONDA, N ;
MACHIDA, K ;
TSUKADA, J ;
KAIZU, H ;
HOSOBA, M .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1987, 13 (08) :404-407
[4]  
KING MA, 1983, J NUCL MED, V24, P1039
[5]   A WIENER FILTER FOR NUCLEAR-MEDICINE IMAGES [J].
KING, MA ;
DOHERTY, PW ;
SCHWINGER, RB ;
PENNEY, BC .
MEDICAL PHYSICS, 1983, 10 (06) :876-880
[6]  
KNESAUREK K, 1989, J NUCL MED, V30, P1666
[7]   Choice of collimator for cardiac SPET when resolution compensation is included in iterative reconstruction [J].
Lau, YH ;
Hutton, BF ;
Beekman, FJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (01) :39-47
[8]  
LEWITT RM, 1989, SPIE P, V1092, P232
[9]  
MADSEN MT, 1985, J NUCL MED, V26, P395
[10]  
MORI I, UNPUB ANN NUCL MED