Investigation of transmission computed tomography (CT) image quality and x-ray dose achievable from an experimental dual-mode benchtop x-ray fluorescence CT and transmission CT system

被引:6
作者
Deng, Luzhen [1 ,2 ]
Yasar, Selcuk [2 ]
Ahmed, Md Foiez [2 ]
Jayarathna, Sandun [2 ]
Feng, Peng [1 ]
Wei, Biao [1 ]
Vedantham, Srinivasan [3 ]
Karellas, Andrew [3 ]
Cho, Sang Hyun [2 ,4 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Optoelect Technol & Syst, Chongqing, Peoples R China
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX USA
[3] Univ Arizona, Dept Med Imaging, Tucson, AZ USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
Computed tomography; x-ray fluorescence computed tomography; x-ray dose; image resolution; GOLD NANOPARTICLES; RECONSTRUCTION; PROJECTION; XFCT;
D O I
10.3233/XST-180457
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVE: To investigate the image quality and x-ray dose associated with a transmission computed tomography (CT) component implemented within the same platform of an experimental benchtop x-ray fluorescence CT (XFCT) system for multimodal preclinical imaging applications. METHODS: Cone-beam CT scans were performed using an experimental benchtop CT + XFCT system and a cylindrically-shaped 3D-printed polymethyl methacrylate phantom (3 cm in diameter, 7 cm in height) loaded with various concentrations (0.05-1 wt. %) of gold nanoparticles (GNPs). Two commercial CT quality assurance phantoms containing 3D line-pair (LP) targets and contrast targets were also scanned. The x-ray beams of 40 and 62 kVp, both filtered by 0.08 mm Cu and 0.4 mm Al, were used with 17 ms of exposure time per projection at three current settings (2.5, 5, and 10 mA). The ordered-subset simultaneous algebraic reconstruction and total variation-minimization methods were used to reconstruct images. Sparse projection and short scan were considered to reduce the x-ray dose. The contrast-to-noise ratio (CNR) and modulation transfer function (MTF) were calculated. RESULTS: The lowest detectable concentration of GNPs (CNR > 5) and the highest spatial resolution (per MTF50%) were 0.10 wt. % and 9.5 LP/CM, respectively, based on the images reconstructed from 360 projections of the 40 kVp beam (or x-ray dose of 3.44 cGy). The background noise for the image resulting in the lowest GNP detection limit was 25 Hounsfield units. CONCLUSION: The transmission CT component within the current experimental benchtop CT + XFCT system produced images deemed acceptable for multimodal (CT + XFCT) imaging purposes, with less than 4 cGy of x-ray dose.
引用
收藏
页码:431 / 442
页数:12
相关论文
共 36 条
[1]   A Monte Carlo Model of a Benchtop X-Ray Fluorescence Computed Tomography System and Its Application to Validate a Deconvolution-Based X-Ray Fluorescence Signal Extraction Method [J].
Ahmed, Md Foiez ;
Yasar, Selcuk ;
Cho, Sang Hyun .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (11) :2483-2492
[2]  
[Anonymous], 2002, 2002 IEEE NUCL SCI S
[3]  
[Anonymous], 1989, INT COMMISSION RAD U
[4]  
[Anonymous], 2001 IEEE NUCL SCI S
[5]  
[Anonymous], P 1993 IEEE NUCL SCI
[6]  
[Anonymous], NUCL SCI S MED IM C
[7]   Investigation of X-ray Fluorescence Computed Tomography (XFCT) and K-Edge Imaging [J].
Bazalova, Magdalena ;
Kuang, Yu ;
Pratx, Guillem ;
Xing, Lei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (08) :1620-1627
[8]   A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems [J].
Beck, Amir ;
Teboulle, Marc .
SIAM JOURNAL ON IMAGING SCIENCES, 2009, 2 (01) :183-202
[9]   Improved sensitivity of computed tomography towards iodine and gold nanoparticle contrast agents via iterative reconstruction methods [J].
Bernstein, Ally Leigh ;
Dhanantwari, Amar ;
Jurcova, Martina ;
Cheheltani, Rabee ;
Naha, Pratap Chandra ;
Ivanc, Thomas ;
Shefer, Efrat ;
Cormode, David Peter .
SCIENTIFIC REPORTS, 2016, 6
[10]  
Boone John M, 2004, Mol Imaging, V3, P149, DOI 10.1162/1535350042380326