Comparing CPAP masks during initial titration for Obstructive Sleep Apnea Syndrome: one-year experience

被引:4
|
作者
Zonato, Adriane Iurck [1 ]
Adriano Rosa, Cintia Felicio [1 ]
Oliveira, Luciana [2 ]
Bittencourt, Lia [2 ]
机构
[1] Hosp IPO, Inst Paranaense Otorrinolaringologista, Curitiba, Parana, Brazil
[2] Univ Fed Sao Paulo UNIFESP, Sao Paulo, SP, Brazil
关键词
CPAP; Titration; Mask; Nasal pillow; Oronasal; POSITIVE AIRWAY PRESSURE; ORONASAL MASK; NASAL; INTERFACE; EFFICACY; IMPACT;
D O I
10.1016/j.bjorl.2021.10.007
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: Continuous Positive Airway Pressure (CPAP) is the gold standard treatment for OSA. A wide variety of masks are used during CPAP therapy. The aim of the study is to compare polysomnography outcomes during titration for different types of masks (oronasal, nasal and pillow) and assess the impact on PAP titration. Methods: We retrospectively analyzed all CPAP titration polysomnography for one year. Anthropometric data and baseline apnea severity were documented. Results: A total of 497 patients were evaluated. Nasal masks were used in 82.3% (n = 409), pillow in 14.1% (n = 70) and oronasal in 3.6% (n = 18). There was no difference according to body mass index and baseline apnea-hypopnea index among the groups. The oronasal group was older and had higher titrated CPAP pressure, higher residual apnea-hypopnea index, lower sleep efficiency, more superficial N1 sleep and longer wake time after sleep onset. All other polysomnography outcomes were similar among the groups. The mean CPAP level was 11.6 +/- 2.1 cm H2O for the oronasal mask, 10.1 +/- 2.1 cm H2O for the nasal mask and 9.8 +/- 2.2 cm H2O for the pillow. The residual apnea-hypopnea index was 10.4 +/- 7.9 for the oronasal mask, 5.49 +/- 5.34 events/h for the nasal mask and 4.98 +/- 5.48 events/h for the pillow. The baseline apnea-hypopnea index was correlated with of a higher CPAP pressure for all the groups (p < 0.001 for the nasal group, p = 0.001 for the pillow group and p = 0.049 for the oronasal group). Body mass index and residual AHI were correlated with of a higher CPAP pressure for the nasal and pillow groups only (p < 0.001). Conclusion: The interface can have a significant impact on the effectiveness of PAP titration. Patients with oronasal masks have higher CPAP pressure, higher residual apnea-hypopnea index, lower sleep efficiency and higher wake time after sleep onset. Oronasal masks should not be recommended as the first choice for apnea patients. (c) 2021 Associacao Brasileira de Otorrinolaringologia e Cirurgia Cervico-Facial. Published by Elsevier Editora Ltda. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:S63 / S68
页数:6
相关论文
共 50 条
  • [1] Equivalence of Nasal and Oronasal Masks during Initial CPAP Titration for Obstructive Sleep Apnea Syndrome
    Teo, Ming
    Amis, Terence
    Lee, Sharon
    Falland, Karina
    Lambert, Stephen
    Wheatley, John
    SLEEP, 2011, 34 (07) : 951 - 955
  • [2] Efficacy of nasal masks versus nasal pillows masks during continuous positive airway pressure titration for patients with obstructive sleep apnea
    Zonato, Adriane Iurck
    Rosa, Cintia Felicio Adriano
    Oliveira, Luciana
    Bittencourt, Lia Rita
    SLEEP AND BREATHING, 2021, 25 (03) : 1487 - 1494
  • [3] Efficacy of nasal masks versus nasal pillows masks during continuous positive airway pressure titration for patients with obstructive sleep apnea
    Adriane Iurck Zonato
    Cíntia Felicio Adriano Rosa
    Luciana Oliveira
    Lia Rita Bittencourt
    Sleep and Breathing, 2021, 25 : 1 - 8
  • [4] The effect of CPAP on obstructive sleep apnea hypopnea syndrome during pregnancy
    Jia, Mingwang
    Liao, Guangyuan
    Peng, Fang
    Yang, Jialin
    Gao, Yuanmei
    Xu, Wenting
    Xu, Zhong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 13 (09): : 6644 - 6652
  • [5] The Baveno Classification as a Predictor of CPAP Titration Pressure in Obstructive Sleep Apnea Syndrome
    Ehab, Ahmed
    Kempa, Axel T.
    Englert, Harald
    Bittar, Shaza Almasri
    Yousef, Aida M.
    Abdelwahab, Heba Wagih
    ADVANCES IN RESPIRATORY MEDICINE, 2023, 91 (06) : 571 - 579
  • [6] Prediction of Effective CPAP Level in Obstructive Sleep Apnea Syndrome
    Korkmaz, Selda
    Ismailogullari, Sevda
    Duman, Ayse
    Aksu, Murat
    JOURNAL OF NEUROLOGICAL SCIENCES-TURKISH, 2012, 29 (01): : 11 - 17
  • [7] Prevalence of central sleep apnea during continous positive airway pressure (CPAP) titration in subjects with obstructive sleep apnea syndrome at an altitude of 2640 m
    Bazurto Zapata, Maria Angelica
    Martinez-Guzman, William
    Vargas-Ramirez, Leslie
    Herrera, Karen
    Gonzalez-Garcia, Mauricio
    SLEEP MEDICINE, 2015, 16 (03) : 343 - 346
  • [8] The value of auto-adjustable CPAP devices in pressure titration and treatment of patients with obstructive sleep apnea syndrome
    Hertegonne, Katrien
    Bauters, Fre
    SLEEP MEDICINE REVIEWS, 2010, 14 (02) : 115 - 119
  • [9] Average volume-assured pressure support for patients with obstructive sleep apnea with failed CPAP titration
    Watanabe, Naomitsu
    Levri, John M.
    Peng, Victor T.
    Scharf, Steven M.
    Diaz-Abad, Montserrat
    SLEEP SCIENCE, 2022, 15 : 328 - 332
  • [10] Impact of different nasal masks on CPAP therapy for obstructive sleep apnea: a randomized comparative trial
    Neuzeret, Pierre-Charles
    Morin, Laurent
    CLINICAL RESPIRATORY JOURNAL, 2017, 11 (06) : 990 - 998