BIOMECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONE

被引:8
|
作者
Mansur, Henrique [1 ,2 ]
Alvarez, Rafael [2 ]
Freitas, Anderson [3 ]
Goncalves, Cesar Barbosa [4 ]
Freitas Ramos, Max Rogerio [1 ]
机构
[1] Univ Fed Estado Rio De Janeiro, Rio De Janeiro, RJ, Brazil
[2] Hosp Forca Aerea Brasilia, Brasilia, DF, Brazil
[3] HOME, Brasilia, DF, Brazil
[4] Hosp Naval Marcilio Dias, Rio De Janeiro, RJ, Brazil
来源
ACTA ORTOPEDICA BRASILEIRA | 2018年 / 26卷 / 03期
关键词
Bone screws; Femoral neck; Hip fractures; CANNULATED HIP SCREWS; CHOICE; FEMUR;
D O I
10.1590/1413-785220182603182288
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To analyze the results of biomechanical assays of the fixation of Pauwels type II femoral neck fractures in synthetic bones, using two parallel cannulated screws or three cannulated screws in an inverted pyramid formation. Methods: Ten Brazilian-made synthetic bones were divided into 2 groups. Groups A and B utilized three and two cannulated screws, respectively, after osteotomy in the middle third of the femur, perpendicular to the axis of the femoral neck, simulating a Pauwels type II femoral neck fracture. The resistance of these fixations was analyzed by compression on the axis of the force resulting from hip compression, simulated with a manual hydraulic press. The T-test and post hoc analysis were used to compare the groups, and the significance criterion adopted was p < 0.05. Results: In group A, which used fixation with three screws, synthesis failure was seen at a mean force of 526 N. In group B, which used two screws, the mean force was 466 N. The results presented a statistically significant difference (p = 0.02). Conclusion: The osteosynthesis of femoral neck fractures in synthetic bone fixated with two screws presented inferior results to fixation with three screws.
引用
收藏
页码:162 / 165
页数:4
相关论文
共 50 条
  • [1] MECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION IN SYNTHETIC BONE
    Freitas, Anderson
    Soares Azevedo, Bruna Alves
    de Souza, Roberto Rodrigues
    da Costa, Helio Ismael
    Maciel, Rafael Almeida
    de Macedo Souto, Diogo Ranier
    ACTA ORTOPEDICA BRASILEIRA, 2014, 22 (03): : 155 - 158
  • [2] MECHANICAL ANALYSIS OF FEMORAL NECK FRACTURE FIXATION WITH DYNAMIC CONDYLAR SCREW IN SYNTHETIC BONE
    Freitas, Anderson
    Maciel, Rafael Almeida
    Lima, Renato de Almeida
    de Macedo Souto, Diogo Ranier
    Ferrer, Marcelo de Almeida
    ACTA ORTOPEDICA BRASILEIRA, 2014, 22 (05): : 264 - 268
  • [3] A Biomechanical Comparison of Two Triple-Screw Methods for Femoral Neck Fracture Fixation in a Synthetic Bone Model
    Zdero, Rad
    Keast-Butler, Oliver
    Schemitsch, Emil H.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (06): : 1537 - 1544
  • [4] Biomechanical analysis of the computer-assisted internal fixation of a femoral neck fracture
    Lu, Hui
    Shen, Hongquan
    Zhou, Shuqing
    Ni, Weidong
    Jiang, Dianming
    GENES & DISEASES, 2020, 7 (03) : 448 - 455
  • [5] BIOMECHANICAL STUDY ON FEMORAL-NECK FRACTURE FIXATION IN RELATION TO BONE-MINERAL DENSITY
    GOH, JCH
    SHAH, KM
    BOSE, K
    CLINICAL BIOMECHANICS, 1995, 10 (06) : 304 - 308
  • [6] Biomechanical analysis of fixation strength at different nailing angles for femoral neck fracture with insufficient reduction
    Wang, Hong-run
    Li, Ji
    Zhang, Li-feng
    Li, Dong-mei
    Han, Biao
    Li, Bin
    Li, Jun-ran
    Li, Li-geng
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (13) : 1949 - 1959
  • [7] Ordinary Cannulated Compression Screws or Headless Cannulated Compression Screws? A Synthetic Bone Biomechanical Research in the Internal Fixation of Vertical Femoral Neck Fracture
    Zhang, Baokun
    Liu, Jingwen
    Zhang, Wei
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [8] A BIOMECHANICAL VALIDATION OF A NEW FEMORAL NECK FIXATION DYNAMIC HIP SCREW FOR PROXIMAL FEMORAL FRACTURE
    Lin, Shih-Wei
    Wang, Jaw-Lin
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2010, 22 (01): : 53 - 59
  • [9] Neck fracture of femoral stems with a sharp slot at the neck: biomechanical analysis
    Yoshimoto, Kensei
    Nakashima, Yasuharu
    Nakamura, Akihiro
    Mawatari, Taro
    Todo, Mitsugu
    Hara, Daisuke
    Iwamoto, Yukihide
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (05) : 881 - 887
  • [10] Biomechanical Analysis of Fixation Devices for Basicervical Femoral Neck Fractures
    Johnson, Joseph
    Deren, Matthew
    Chambers, Alison
    Cassidy, Dale
    Koruprolu, Sarath
    Born, Christopher