Mechanical and Geometrical Properties Assessment of Thermoplastic Materials for Biomedical Application

被引:17
作者
Barone, Sandro [1 ]
Paoli, Alessandro [1 ]
Neri, Paolo [1 ]
Razionale, Armando Viviano [1 ]
Giannese, Michele [1 ]
机构
[1] Univ Pisa, DICI Dept Civil & Ind Engn, I-56100 Pisa, Italy
来源
ADVANCES ON MECHANICS, DESIGN ENGINEERING AND MANUFACTURING | 2017年
关键词
3D Human Modeling; Virtual Design; Clear Aligner; Thermoforming Process; Mechanical Properties Assessment; Optical 3D Scanner; INCISOR; FORCES;
D O I
10.1007/978-3-319-45781-9_44
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Clear thermoplastic aligners are nowadays widely used in orthodontics for the correction of malocclusion or teeth misalignment defects. The treatment is virtually designed with a planning software that allows for a definition of a sequence of little movement steps from the initial tooth position to the final desired one. Every single step is transformed into a physical device, the aligner, by the use of a 3D printed model on which a thin foil of plastic material is thermoformed. Manufactured aligners could have inherent limitations such as dimensional instability, low strength, and poor wear resistance. These issues could be associated with material characteristics and/or with the manufacturing processes. The present work aims at the characterization of the manufactured orthodontic devices. Firstly, mechanical properties of different materials have been assessed through a set of tensile tests under diftrent experimental conditions. The tests have the purpose of analyzing the eftct that the forming process and the normal use of the aligner may have on mechanical properties of the material. The manufacturing process could also introduce unexpected limitations in the resulting aligners. This would be a critical element to control in order to establish resulting forces on teeth. Several studies show that resulting forces could be greatly influenced by the aligner thickness. A method to easily measure the actual thickness of the manufactured aligner is proposed. The analysis of a number of real cases shows as the thickness is far to be uniform and could vary strongly along the surface of the tooth.
引用
收藏
页码:436 / 445
页数:10
相关论文
共 15 条
  • [1] [Anonymous], 2012, 52712012EN ISO
  • [2] Barone S., P PART 9 INT JOINT C, P44
  • [3] Computer-aided modelling of three-dimensional maxillofacial tissues through multi-modal imaging
    Barone, Sandro
    Paoli, Alessandro
    Razionale, Armando V.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H2) : 89 - 104
  • [4] Multiple alignments of range maps by active stereo imaging and global marker framing
    Barone, Sandro
    Paoli, Alessandro
    Razionale, Armando Viviano
    [J]. OPTICS AND LASERS IN ENGINEERING, 2013, 51 (02) : 116 - 127
  • [5] Development of an artificial saliva solution for studying the corrosion behavior of dental alloys
    Duffó, GS
    Castillo, EQ
    [J]. CORROSION, 2004, 60 (06) : 594 - 602
  • [6] Initial Forces and Moments Delivered by Removable Thermoplastic Appliances during Rotation of an Upper Central Incisor
    Hahn, Wolfram
    Engelke, Benjamin
    Jung, Klaus
    Dathe, Henning
    Fialka-Fricke, Julia
    Kubein-Meesenburg, Dietmar
    Sadat-Khonsari, Reza
    [J]. ANGLE ORTHODONTIST, 2010, 80 (02) : 239 - 246
  • [7] Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping
    Hahn, Wolfram
    Dathe, Henning
    Fialka-Fricke, Julia
    Fricke-Zech, Susanne
    Zapf, Antonia
    Kubein-Meesenburg, Dietmar
    Sadat-Khonsari, Reza
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 12.e1 - 12.e7
  • [8] Mechanical Properties of Orthodontic Thermoplastics PETG/PC2858 after Blending
    Ma, Yan Song
    Fang, Dong Yu
    Zhang, Ning
    Ding, Xue Jia
    Zhang, Kun Ya
    Bai, Yu Xing
    [J]. CHINESE JOURNAL OF DENTAL RESEARCH, 2016, 19 (01) : 43 - 48
  • [9] A comparison between customized clear and removable orthodontic appliances manufactured using RP and CNC techniques
    Martorelli, Massimo
    Gerbino, Salvatore
    Giudice, Michele
    Ausiello, Pietro
    [J]. DENTAL MATERIALS, 2013, 29 (02) : E1 - E10
  • [10] A comparison of treatment impacts between invisalign aligner and fixed appliance therapy during the first week of treatment
    Miller, Kevin B.
    McGorray, Susan P.
    Womack, Randy
    Qunitero, Juan Carlos
    Perelmuter, Mark
    Gibson, Jerome
    Dolan, Teresa A.
    Wheeler, Timothy T.