Conversion to Reverse Total Shoulder Arthroplasty with and without Humeral Stem Retention: The Role of a Convertible-Platform Stem

被引:30
作者
Crosby, Lynn A. [1 ]
Wright, Thomas W. [2 ]
Yu, Stephen [3 ]
Zuckerman, Joseph D. [3 ]
机构
[1] Georgia Regents Univ, Dept Orthopaed Surg, Augusta, GA 30912 USA
[2] Univ Florida, Dept Orthopaed & Rehabil, Gainesville, FL USA
[3] NYU, Langone Med Ctr, Dept Orthopaed Surg, New York, NY USA
关键词
MULTICENTER; COMPONENT; REVISION;
D O I
10.2106/JBJS.16.00683
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Revision shoulder arthroplasty is a technically challenging procedure. It is associated with increased blood loss and operative time, and it frequently necessitates revision implants, augments, and bone-grafting. Shoulder arthroplasty systems with a convertible-platform humeral stem have been developed to reduce the complexity of revision procedures by eliminating the need for humeral component explantation when converting from anatomic shoulder arthroplasty (hemiarthroplasty or total shoulder arthroplasty) to reverse total shoulder arthroplasty (rTSA). Methods: A multicenter, retrospective analysis involving 102 consecutive shoulders (102 patients) that underwent revision of an anatomic shoulder arthroplasty to an rTSA was conducted. During the revision, 73 of the shoulders needed exchange of the humeral stem (the exchange group) and 29 had retention of a convertible-platform humeral component (the retention group). Patient demographics, operative time, blood management, range of motion, complications, and patient-reported outcomes were compared between the 2 groups. Results: Patients with retention had significantly shorter operative time (mean and standard deviation, 130 +/- 48 versus 195 +/- 58 minutes; p < 0.001) and lower estimated blood loss (292 +/- 118 versus 492 +/- 334 mL; p = 0.034). The rate of intraoperative complications was lower in the retention group (0% versus 15%; p = 0.027). Patients with retention had slightly better postoperative range of motion (active external rotation, 26 degrees +/- 23 degrees versus 11 degrees +/- 23 degrees[p = 0.006]; active forward elevation, 112 degrees +/- 37 degrees versus 96 degrees +/- 33 degrees [p = 0.055]). Conclusions: Shoulder arthroplasty systems that utilize a convertible-platform humeral stem offer an advantage for rTSA conversion in that a well-fixed, well-positioned humeral stem can be retained. There were significantly fewer complications as well as significantly decreased blood loss and operative time when a convertible-platform stem was utilized (p < 0.050).
引用
收藏
页码:736 / 742
页数:7
相关论文
共 22 条
[1]  
[Anonymous], 2016, ORTHOPEDIC NETWORK N, V27
[2]   Conversion of shoulder arthroplasty to reverse implants: clinical and radiological results using a modular system [J].
Castagna, Alessandro ;
Delcogliano, Marco ;
de Caro, Francesca ;
Ziveri, Giovanni ;
Borroni, Mario ;
Gumina, Stefano ;
Postacchini, Franco ;
De Biase, Carlo Felice .
INTERNATIONAL ORTHOPAEDICS, 2013, 37 (07) :1297-1305
[3]   Survivorship of the humeral component in shoulder arthroplasty [J].
Cil, Akin ;
Veillette, Christian J. H. ;
Sanchez-Sotelo, Joaquin ;
Sperling, John W. ;
Schleck, Cathy D. ;
Cofield, Robert H. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (01) :143-150
[4]  
CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
[5]  
Crosby LA, 2012, 23 ANN BESS SCI M 20
[6]   Prevalence and projections of total shoulder and elbow arthroplasty in the United States to 2015 [J].
Day, Judd S. ;
Lau, Edmund ;
Ong, Kevin L. ;
Williams, Gerald R. ;
Ramsey, Matthew L. ;
Kurtz, Steven M. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (08) :1115-1120
[7]   Conversion to Reverse Shoulder Arthroplasty: Humeral Stem Retention Versus Revision [J].
Dilisio, Matthew F. ;
Miller, Lindsay R. ;
Siegel, Elana J. ;
Higgins, Laurence D. .
ORTHOPEDICS, 2015, 38 (09) :E773-E779
[8]  
Duquin TR, 2011, J SHOULDER ELB SURG, V21, P44
[9]  
Frankle MA., 2016, Reverse shoulder arthroplasty: biomechanics, clinical techniques, and current technologies
[10]   Results of revision from hemiarthroplasty to total shoulder arthroplasty utilizing modular component systems [J].
Groh, Gordon I. ;
Wirth, Michael A. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (05) :778-782