摘要
This paper reports for the first time a multisyringe flow injection analysis (MSFIA) method with potentiometric detection for the automated determination of chloride in waters. The methodology developed was applied to the determination of chloride in mineral, tap and waste waters and the results achieved were compared with those obtained by a potentiometric sequential injection analysis (SIA) method reported in the literature. When Mohr titration was carried out for validating the results offered by both techniques, no significant differences were found. The linear ranges were between 6 and 3500 mg 1(-1) for MSFIA and 10 and 3500 mg 1(-1) for SIA; the UPAC limits of detection were 2.7 mg 1(-1) for MSFIA and 1.6 mg 1(-1) for SIA; reproducibility was ca. 0.8% for MSFIA and 0.4% for SIA and, sampling rates were of 30 and 15 injections h(-1) for MSFIA and SIA, respectively. These results provide evidence of superior performance of MSFIA over SIA for the determination of chloride. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 50 条
[21]   Multisyringe flow injection analysis hyphenated with liquid core waveguides for the development of cleaner spectroscopic analytical methods: improved determination of chloride in waters [J].
Fernando Maya ;
José Manuel Estela ;
Víctor Cerdà .
Analytical and Bioanalytical Chemistry, 2009, 394 :1577-1583
[22]   Flow injection potentiometric determination of chlorpromazine [J].
Sales, MGF ;
Tomás, JFC ;
Lavandeira, SR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) :1280-1286
[23]   Potentiometric flow injection determination of salbutamol [J].
Abdel-Ghani, NT ;
Rizk, MS ;
El-Nashar, RM .
ANALYTICAL LETTERS, 2002, 35 (01) :39-52
[24]   A multisyringe flow injection method for the determination of thorium in water samples using spectrophotometric detection [J].
Guzman-Mar, Jorge L. ;
Hernandez-Ramirez, Aracely ;
Lopez-Chuken, Ulrico J. ;
Lopez-de-Alba, Pedro L. ;
Cerda, Victor .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 289 (01) :67-73
[25]   A multisyringe flow injection method for the determination of thorium in water samples using spectrophotometric detection [J].
Jorge L. Guzmán-Mar ;
Aracely Hernández-Ramírez ;
Ulrico J. López-Chuken ;
Pedro L. López-de-Alba ;
Víctor Cerdà .
Journal of Radioanalytical and Nuclear Chemistry, 2011, 289
[26]   Multisyringe flow injection analysis hyphenated with liquid core waveguides for the development of cleaner spectroscopic analytical methods: improved determination of chloride in waters [J].
Maya, Fernando ;
Manuel Estela, Jose ;
Cerda, Victor .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (06) :1577-1583
[27]   Conductometric determination of ammonium by a multisyringe flow injection system applying gas diffusion [J].
Henriquez, Camelia ;
Horstkotte, Burkhard ;
Cerda, Victor .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (12) :1236-1252
[28]   Multisyringe flow injection spectrophotometric determination of uranium in water samples [J].
Jorge L. Guzmán Mar ;
Leticia López Martínez ;
Pedro L. López de Alba ;
Nancy Ornelas Soto ;
Víctor Cerdà Martín .
Journal of Radioanalytical and Nuclear Chemistry, 2009, 281 :433-439
[29]   An environmental friendly method for the automatic determination of hypochlorite in commercial products using multisyringe flow injection analysis [J].
Ornelas Soto, N. ;
Horstkotte, B. ;
March, J. G. ;
Lopez de Alba, P. L. ;
Lopez Martinez, L. ;
Cerda Martin, V. .
ANALYTICA CHIMICA ACTA, 2008, 611 (02) :182-186
[30]   FLOW-INJECTION ANALYSIS WITH TETRAMERIC CALIXARENE-BASED POTENTIOMETRIC DETECTION [J].
TELTINGDIAZ, M ;
DIAMOND, D ;
SMYTH, MR .
ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) :149-155