Thermodynamic and economic performance of the LiBr-H2O single stage absorption water chiller

被引:27
|
作者
Mroz, Tomasz M. [1 ]
机构
[1] Poznan Univ Tech, Inst Environm Engn, PL-60965 Poznan, Poland
关键词
absorption chiller; energy efficiency; economic performance;
D O I
10.1016/j.applthermaleng.2006.04.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
The LiBr-H2O single stage absorption water chiller, installed at the Municipal CHP plant of the city of Poznan, Poland was examined in order to find its energy performance. The 495 kW water chiller is used for CHP plant technological rooms air conditioning (e.g. control rooms, power supply rooms). The superheated steam (p = 1.0 MPa, t = 250 degrees C) is the heat source for the generator and cooling water for the absorber and condenser is supplied from the existing cooling water installation. The chilled water temperature is set at 6 degrees C. On the basis of online temperature and media flow measurements, the system's energy balance was created. Employing the first law of thermodynamics the energy balance equation was solved and used for the derivation of the chiller's COP factor. The work's main goal was to establish the influence of the chiller's actual load on the energy efficiency of the system. The economic evaluation of cooling energy unit price was carried out on the basis of the measured chiller's COP factor. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2103 / 2109
页数:7
相关论文
共 39 条
  • [1] Performance Test of a Small Size LiBr-H2O Absorption Chiller
    Prasartkaew, Boonrit
    11TH ECO-ENERGY AND MATERIALS SCIENCE AND ENGINEERING (11TH EMSES), 2014, 56 : 487 - 497
  • [2] Modeling the dynamic simulation and control of a single effect LiBr-H2O absorption chiller
    Xu, Yu-jie
    Zhang, Shi-jie
    Xiao, Yun-han
    APPLIED THERMAL ENGINEERING, 2016, 107 : 1183 - 1191
  • [3] Thermodynamic Modeling and Optimization of Double Effect Series flow LiBr-H2O Vapor Absorption Chiller
    Ghani, Muhammad Usman
    Zaman, Muhammad
    Khan, Imran
    2016 INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2016,
  • [4] Solar Driven LiBr-H2O Absorption Chiller Simulation to Analyze Two Backup Options
    Ibrahim, Furugaan
    Chirarattananon, Surapong
    Rakkwamsuk, Pattana
    Chaiwiwatworakul, Pipat
    Chuangchote, Surawut
    Hien, Vu Duc
    INTERNATIONAL ENERGY JOURNAL, 2021, 21 (03): : 361 - 374
  • [5] Optimal control of single stage LiBr/water absorption chiller
    Sabbagh, Alejandro A.
    Gomez, Jorge M.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 92 : 1 - 9
  • [6] Solution Crystallization Detection for double-effect LiBr-H2O steam absorption chiller
    Gilani, Syed Ihtsham-ul-Haq
    Ahmed, Mojahid Sidahmed Mohammed Salih
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 1522 - 1528
  • [7] Comparison between two LiBr-H2O absorption-compression chillers and a simple absorption chiller driven by various solar collectors: Exergy-economic performance and optimization
    Hai, Tao
    Zoghi, Mohammad
    Habibi, Hamed
    ENERGY, 2023, 282
  • [8] Model based experimental performance analysis of a microscale LiBr-H2O steam-driven double-effect absorption Chiller
    Yin, Hongxi
    Qu, Ming
    Archer, David H.
    APPLIED THERMAL ENGINEERING, 2010, 30 (13) : 1741 - 1750
  • [9] Dynamic study of a single effect absorption chiller using the pair LiBr/H2O
    Ochoa, A. A. V.
    Dutra, J. C. C.
    Henriquez, J. R. G.
    dos Santos, C. A. C.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 108 : 30 - 42
  • [10] Development of direct seawater-cooled LiBr-H2O absorption chiller and its application in industrial waste heat utilization
    Du, Shuai
    Xu, Zhenyuan
    Wang, Ruzhu
    Yang, Chun
    ENERGY, 2024, 294