Differentiation of heroin and cocaine using dual-energy CT-an experimental study

被引:12
|
作者
Grimm, Jochen [1 ,2 ,3 ,4 ]
Wudy, Ramona [1 ]
Ziegeler, Edvard [1 ]
Wirth, Stefan [1 ]
Uhl, Michael [5 ]
Reiser, Maximilian F. [1 ]
Scherr, Michael [1 ]
机构
[1] Ludwig Maximilians Univ Hosp Munich, Inst Clin Radiol, D-80336 Munich, Germany
[2] Univ Lausanne Hosp, Dept Med Radiol, CH-1011 Lausanne, Switzerland
[3] Univ Lausanne, CH-1011 Lausanne, Switzerland
[4] Ctr Legal Med Lausanne & Geneva, CH-1011 Lausanne, Switzerland
[5] Bavarian State Criminal Police Off, D-80636 Munich, Germany
关键词
Body packing; Dual-energy CT; Dual-energy index; Material differentiation; Illicit drugs; DOSE COMPUTED-TOMOGRAPHY; BODY-PACKING; PACKERS; RADIOGRAPHY; STUFFERS; PUSHERS; SURGERY; DRUGS;
D O I
10.1007/s00414-014-0980-6
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
To evaluate if heroin and cocaine can be distinguished using dual-energy CT. Twenty samples of heroin and cocaine at different concentrations and standardized compression (SC) were scanned in dual-energy mode on a newest generation Dual Energy 64-row MDCT scanner. CT number, spectral graphs, and dual-energy index (DEI) were evaluated. Results were prospectively tested on six original samples from a body packer. Wilcoxon's test was used for statistical evaluation. Values are given as median and range. Under SC, the CT number of cocaine samples (-29.87 Hounsfield unit (HU) [-125.85; 16.16 HU]) was higher than the CT number of heroin samples (-184.37 HU [-199.81; -159.25 HU]; p < 0.01). Slope of spectral curves for cocaine was -2.36 HU/keV [-7.15; -0.67 HU/keV], and for heroin, 1.75 HU/keV [1.28; 2.5 HU/keV] (p < 0.01). DEI was 0.0352 [0.0081; 0.0528] for cocaine and significantly higher than for heroin samples (-0.0127 [-0.0097; -0.0159]; p < 0.001). While CT number was inconclusive, all six original packs were correctly classified after evaluation of the spectral curve and DEI. In contrast to the CT number, slope of the spectral curve and DEI were independent of concentration and compression. The slope of the spectral curve and the DEI from dual-energy CT data can be used to distinguish heroin and cocaine in vitro; these results are independent of compression and concentration in the measured range.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 50 条
  • [1] Differentiation of heroin and cocaine using dual-energy CT—an experimental study
    Jochen Grimm
    Ramona Wudy
    Edvard Ziegeler
    Stefan Wirth
    Michael Uhl
    Maximilian F. Reiser
    Michael Scherr
    International Journal of Legal Medicine, 2014, 128 : 475 - 482
  • [2] Dual-energy CT behavior of heroin, cocaine, and typical adulterants
    Patrick J. Laberke
    Juergen Fornaro
    Suk-kyum Kim
    Simon Blum
    Marc Augsburger
    Hatem Alkadhi
    Simon Wildermuth
    Roland Hausmann
    Sebastian Leschka
    Forensic Science, Medicine, and Pathology, 2015, 11 : 20 - 28
  • [3] Dual-energy CT behavior of heroin, cocaine, and typical adulterants
    Laberke, Patrick J.
    Fornaro, Juergen
    Kim, Suk-kyum
    Blum, Simon
    Augsburger, Marc
    Alkadhi, Hatem
    Wildermuth, Simon
    Hausmann, Roland
    Leschka, Sebastian
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2015, 11 (01) : 20 - 28
  • [4] Differentiation with the Dual-Energy CT
    Krome, Susanne
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (08): : 689 - 689
  • [5] An experimental study of dual-energy CT imaging using synchrotron radiation
    HAO Jia
    ZHANG Li
    XING Yuxiang
    KANG Kejun
    Nuclear Science and Techniques, 2013, 24 (02) : 7 - 11
  • [6] An experimental study of dual-energy CT imaging using synchrotron radiation
    Hao Jia
    Zhang Li
    Xing Yuxiang
    Kang Kejun
    NUCLEAR SCIENCE AND TECHNIQUES, 2013, 24 (02)
  • [7] UROGENITAL - Differentiation of Kidney Lesions with Dual-Energy CT
    Bucher, Andreas
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2022, 194 (09): : 953 - 954
  • [8] Differentiation of Kidney Stones Using Dual-Energy CT With and Without a Tin Filter
    Fung, George S. K.
    Kawamoto, Satomi
    Matlaga, Brian R.
    Taguchi, Katsuyuki
    Zhou, Xiaodong
    Fishman, Elliot K.
    Tsui, Benjamin M. W.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (06) : 1380 - 1386
  • [9] Differentiation of malignant from benign orbital tumours using dual-energy CT
    Luo, S.
    Sha, Y.
    Wu, J.
    Lin, N.
    Pan, Y.
    Zhang, F.
    Huang, W.
    CLINICAL RADIOLOGY, 2022, 77 (04) : 307 - 313
  • [10] Pulmonary Embolism Detection with Dual-Energy CT: Experimental Study of Dual-Source CT in Rabbits
    Zhang, Long-Jiang
    Zhao, Yan-E
    Wu, Sheng-Yong
    Yeh, Benjamin M.
    Zhou, Chang-Sheng
    Hu, Xiao-Bo
    Hu, Qiu-Ju
    Lu, Guang-Ming
    RADIOLOGY, 2009, 252 (01) : 61 - 70