A Low-Cost Voltage-to-Current Calibration Technique for Multiple-Sensor Systems

被引:5
|
作者
Chan, Hing Kai [1 ]
Chung, Sai Ho [2 ]
机构
[1] Univ E Anglia, Norwich NR4 7TJ, Norfolk, England
[2] Hong Kong Polytech Univ, Dept Ind Syst Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Calibration; heterogeneity; multiple sensors; piezoresistive; voltage to current;
D O I
10.1109/TIM.2009.2021644
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Systems with multiple sensors pose a problem of heterogeneity, i.e., different sensors have different outputs subject to the same excitation. To tackle this problem, this paper presents a calibration technique for multiple-sensor applications. An array of voltage-to-current converters, followed by a summing inverter, is employed to aggregate the responses of the system, which originated from heterogeneous sensors. The calibration method aims to normalize the output from each independent sensor, so that heterogeneity of the system, like positional error, could be reduced. The performance of the calibration technique had been tested by a prototype with multiple sensors, and the results were found to be satisfactory, which indicates that a reduction from 2% to 0.2% in positional error can be achieved. The proposed method can be implemented by adding only a minimal of passive components, which is suitable for cost-sensitive mass-production-type products.
引用
收藏
页码:73 / 77
页数:5
相关论文
共 50 条
  • [21] Distant calibration of low-cost PM and NO2 sensors; evidence from multiple sensor testbeds
    Hofman, Jelle
    Nikolaou, Mania
    Shantharam, Sharada Prasad
    Stroobants, Christophe
    Weijs, Sander
    La Manna, Valerio Panzica
    ATMOSPHERIC POLLUTION RESEARCH, 2022, 13 (01)
  • [22] SEAMLESS IMAGE-CONNECTION TECHNIQUE FOR A MULTIPLE-SENSOR CAMERA
    UEHIRA, K
    KOMIYA, K
    IEICE TRANSACTIONS ON COMMUNICATIONS, 1994, E77B (02) : 232 - 238
  • [23] Automatic camera calibration for a multiple-sensor integrated coordinate measurement system
    Shen, TS
    Menq, CH
    IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 2001, 17 (04): : 502 - 507
  • [24] A LOW-COST MULTIPLE HALL PROBE CURRENT TRANSDUCER
    SCOVILLE, JT
    PETERSEN, PI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (03): : 755 - 760
  • [25] Development and calibration of a low-cost LIDAR sensor for water level measurements
    Santana, Vinicius Diniz Ferrer
    Salustiano, Rogerio Esteves
    Tiezzi, Rafael de Oliveira
    FLOW MEASUREMENT AND INSTRUMENTATION, 2024, 100
  • [26] A low-cost clock output pixel sensor with self-calibration
    Weng, R. M.
    Yen, C. L.
    Kuo, R. C.
    2007 INTERNATIONAL SYMPOSIUM ON SIGNALS, SYSTEMS AND ELECTRONICS, VOLS 1 AND 2, 2007, : 125 - 128
  • [27] Addressing Low-Cost Methane Sensor Calibration Shortcomings with Machine Learning
    Kiplimo, Elijah
    Riddick, Stuart N.
    Mbua, Mercy
    Upreti, Aashish
    Anand, Abhinav
    Zimmerle, Daniel J.
    ATMOSPHERE, 2024, 15 (11)
  • [28] Multiple PM Low-Cost Sensors, Multiple Seasons' Data, and Multiple Calibration Models
    Srishti, S.
    Agrawal, Pratyush
    Kulkarni, Padmavati
    Gautam, Hrishikesh Chandra
    Kushwaha, Meenakshi
    Sreekanth, V.
    AEROSOL AND AIR QUALITY RESEARCH, 2023, 23 (03)
  • [29] A low-cost force sensor for electromechanical actuation systems
    Rosenbaum, K. A.
    Pekarek, S. D.
    Baudendistel, T.
    Jordan, B.
    2007 IEEE VEHICLE POWER AND PROPULSION CONFERENCE, VOLS 1 AND 2, 2007, : 242 - 249
  • [30] Low-cost localization technique for heterogeneous wireless sensor networks
    Nithya, B.
    Jeyachidra, J.