Maximum-likelihood method for focus-variation image reconstruction in high resolution transmission electron microscopy

被引:296
作者
Coene, WMJ [1 ]
Thust, A [1 ]
deBeeck, M [1 ]
VanDyck, D [1 ]
机构
[1] UNIV ANTWERP, RUCA, EMAT, B-2020 ANTWERP, BELGIUM
关键词
D O I
10.1016/0304-3991(96)00010-1
中图分类号
TH742 [显微镜];
学科分类号
摘要
This paper deals with image reconstruction in high-resolution transmission electron microscopy (HRTEM) via focus variation. This technique aims at the reconstruction of the complex-valued electron wave at the exit plane of the specimen including correction for the aberrations of the microscope, with a focal series of HRTEM images as input. The general case with linear and non-linear contributions to the images is considered, requiring recursive optimization of the wave function, which is obtained by a non-linear least-squares fit to the measured image intensities. Based upon the pioneering work of Kirkland (1984) in this field, we discuss the following improvements, In the first place, a solution of the maximum-likelihood (MAL) equations for image reconstruction is derived in which the - for HRTEM inherent - coupling between the wave function and its complex conjugate is accounted for. Secondly, it is outlined how optimum convergence for the MAL solution is obtained. Thirdly, a computationally efficient implementation of the recursive algorithm to solve the MAL equations is presented. The algorithm is based on a factorization of the spatial coherence envelope, and on a focal integration approach for the temporal coherence envelope in the transmission-cross-coefficient. The convergence behavior of this algorithm is studied using simulated focal series as input.
引用
收藏
页码:109 / 135
页数:27
相关论文
共 38 条
[1]  
[Anonymous], 1991, Advances in optical and electron microscopy
[2]  
BAKKER H, 1995, UNPUB ULTRAMICROSCOP
[3]   THE REAL SPACE METHOD FOR DYNAMICAL ELECTRON-DIFFRACTION CALCULATIONS IN HIGH-RESOLUTION ELECTRON-MICROSCOPY .2. CRITICAL ANALYSIS OF THE DEPENDENCY ON THE INPUT PARAMETERS [J].
COENE, W ;
VANDYCK, D .
ULTRAMICROSCOPY, 1984, 15 (1-2) :41-50
[4]   PHASE RETRIEVAL THROUGH FOCUS VARIATION FOR ULTRA-RESOLUTION IN FIELD-EMISSION TRANSMISSION ELECTRON-MICROSCOPY [J].
COENE, W ;
JANSSEN, G ;
DEBEECK, MO ;
VANDYCK, D .
PHYSICAL REVIEW LETTERS, 1992, 69 (26) :3743-3746
[5]  
COENE W, 1992, SCANNING MICROSCOPY, V6, P379
[6]  
COENE W, 1987, P 6 PFEFF C IM SIGN, P117
[7]  
COENE W, 1988, SCANNING MICROSCOP S, V2
[8]  
COENE WMJ, 1994, MICROSC SOC AM B, V24, P472
[9]  
DERUIJTER WJ, 1992, THESIS
[10]  
FLETCHER R, 1980, PRACTICAL METHODS OP, V1, pCH2