Automated tracking of muscle fascicle orientation in B-mode ultrasound images

被引:81
作者
Rana, Manku [1 ]
Hamarneh, Ghassan [2 ]
Wakeling, James M. [1 ]
机构
[1] Simon Fraser Univ, Sch Biomed Physiol & Kinesiol, Burnaby, BC V5A 1S6, Canada
[2] Simon Fraser Univ, Med Image Anal Lab, Sch Comp Sci, Burnaby, BC V5A 1S6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Muscle fascicle tracking; Segmentation; Functional imaging; VASTUS LATERALIS MUSCLE; IN-VIVO MEASUREMENTS; LENGTH CHANGES; JOINT ANGLE; ARCHITECTURE; TENDON; BEHAVIOR; FIBER; HETEROGENEITY; PENNATION;
D O I
10.1016/j.jbiomech.2009.06.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
B-mode ultrasound can be used to non-invasively image muscle fascicles during both static and dynamic contractions. Digitizing these muscle fascicles can be a timely and subjective process, and usually studies have used the images to determine the linear fascicle lengths. However, fascicle orientations can vary along each fascicle (curvature) and between fascicles. The purpose of this study was to develop and test two methods for automatically tracking fascicle orientation. images were initially filtered using a multiscale vessel enhancement (a technique used to enhance tube-like structures), and then fascicle orientations quantified using either the Radon transform or wavelet analysis. Tests on synthetic images showed that these methods could identify fascicular orientation with errors of less than 0.06 degrees. Manual digitization of muscle fascicles during a dynamic contraction resulted in a standard deviation of angle estimates of 1.41 degrees across ten researchers. The Radon transform predicted fascicle orientations that were not significantly different from the manually digitized values, whilst the wavelet analysis resulted in angles that were 1.35 degrees less, and reasons for these differences are discussed. The Radon transform can be used to identify the dominant fascicular orientation within an image, and thus used to estimate muscle fascicle lengths. The wavelet analysis additionally provides information on the local fascicle orientations and can be used to quantify fascicle curvatures and regional differences with fascicle orientation across an image. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 50 条
  • [41] Automatic Tracking of Muscle Fascicles in Ultrasound Images Using Localized Radon Transform
    Zhao, Heng
    Zhang, Li-Qun
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (07) : 2094 - 2101
  • [42] Implementation of three different segmentation techniques for quantitative evaluation of IMT in B-mode ultrasound common carotid artery images
    Naik, Vaishali
    Gamad, R. S.
    Bansod, Prashant
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2016, 4 (05) : 317 - 326
  • [43] Optimized geometry of the carotid artery cross-section: Comparison between circular and elliptical approximations in B-mode ultrasound images
    Soleimani, Effat
    Saberi, Hazhir
    Ayoobi-Yazdi, Niloofar
    [J]. DISCRETE MATHEMATICS ALGORITHMS AND APPLICATIONS, 2021, 13 (02)
  • [44] Automatic recognition of the common carotid artery in longitudinal ultrasound B-mode scans
    Rossi, Alessandro C.
    Brands, Peter J.
    Hoeks, Arnold P. G.
    [J]. MEDICAL IMAGE ANALYSIS, 2008, 12 (06) : 653 - 665
  • [45] Automatic ROI Segmentation in B-mode Ultrasound Image for Liver Fibrosis Classification
    Lu, Nan-Han
    Kuo, Chung-Ming
    Ding, Hueisch-Jy
    [J]. 2013 INTERNATIONAL SYMPOSIUM ON BIOMETRICS AND SECURITY TECHNOLOGIES (ISBAST), 2013, : 10 - 13
  • [46] Estimation of absolute states of human skeletal muscle via standard B-mode ultrasound imaging and deep convolutional neural networks
    Cunningham, Ryan J.
    Loram, Ian D.
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2020, 17 (162)
  • [47] Improved Myocardial Motion Estimation Combining Tissue Doppler and B-Mode Echocardiographic Images
    Porras, A. R.
    Alessandrini, M.
    De Craene, M.
    Duchateau, N.
    Sitges, M.
    Bijnens, B. H.
    Delingette, H.
    Sermesant, M.
    D'hooge, J.
    Frangi, A. F.
    Piella, G.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (11) : 2098 - 2106
  • [48] Carotid Artery B-Mode Ultrasound Image Segmentation based on Morphology, Geometry and Gradient Direction
    Sunarya, I. Made Gede
    Yuniarno, Eko Mulyanto
    Purnomo, Mauridhi Hery
    Sardjono, Tri Arief
    Sunu, Ismoyo
    Purnama, I. Ketut Eddy
    [J]. SECOND INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION, 2017, 10443
  • [49] Modified spatial neutrosophic clustering technique for boundary extraction of tumours in B-mode BUS images
    Lal, Madan
    Kaur, Lakhwinder
    Gupta, Savita
    [J]. IET IMAGE PROCESSING, 2018, 12 (08) : 1338 - 1344
  • [50] CAROTIDNet: A Novel Carotid Symptomatic/Asymptomatic Plaque Detection System Using CNN-Based Tangent Optimization Algorithm in B-Mode Ultrasound Images
    Ali, Tanweer
    Pathan, Sameena
    Salvi, Massimo
    Meiburger, Kristen M.
    Molinari, Filippo
    Acharya, U. Rajendra
    [J]. IEEE ACCESS, 2024, 12 : 73970 - 73979