ze The Benefits and Challenges of an Interfaced Electronic Health Record and Laboratory Information System Effects on Laboratory Processes

被引:20
作者
Petrides, Athena K. [1 ,4 ]
Bixho, Ida [2 ]
Goonan, Ellen M.
Bates, David W. [2 ,4 ]
Shaykevich, Shimon [2 ,4 ]
Lipsitz, Stuart R. [2 ,4 ]
Landman, Adam B. [3 ,4 ]
Tanasijevic, Milenko J. [1 ,4 ]
Melanson, Stacy E. F. [1 ,4 ]
机构
[1] Brigham & Womens Hosp, Dept Pathol, 75 Francis St,Amory 2, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Dept Med, 75 Francis St, Boston, MA 02115 USA
[3] Brigham & Womens Hosp, Dept Emergency Med, 75 Francis St, Boston, MA 02115 USA
[4] Harvard Med Sch, Boston, MA USA
关键词
PHYSICIAN ORDER ENTRY; IMPLEMENTATION; TECHNOLOGY; MANAGEMENT; ERRORS; TIME;
D O I
10.5858/arpa.2016-0146-OA
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context.-A recent government regulation incentivizes implementation of an electronic health record (EHR) with computerized order entry and structured results display. Many institutions have also chosen to interface their EHR with their laboratory information system (LIS). Objective.-To determine the impact of an interfaced EHR-LIS on laboratory processes. Design.-We analyzed several different processes before and after implementation of an interfaced EHR-LIS: the turnaround time, the number of stat specimens received, venipunctures per patient per day, preanalytic errors in phlebotomy, the number of add-on tests using a new electronic process, and the number of wrong test codes ordered. Data were gathered through the LIS and/or EHR. Results.-The turnaround time for potassium and hematocrit decreased significantly ( P = .047 and P = .004, respectively). The number of stat orders also decreased significantly, from 40% to 7% for potassium and hematocrit, respectively ( P < .001 for both). Even though the average number of inpatient venipunctures per day increased from 1.38 to 1.62 ( P < .001), the average number of preanalytic errors per month decreased from 2.24 to 0.16 per 1000 specimens ( P < .001). Overall there was a 16% increase in add-on tests. The number of wrong test codes ordered was high and it was challenging for providers to correctly order some common tests. Conclusions.-An interfaced EHR-LIS significantly improved within-laboratory turnaround time and decreased stat requests and preanalytic phlebotomy errors. Despite increasing the number of add-on requests, an electronic add-on process increased efficiency and improved provider satisfaction. Laboratories implementing an interfaced EHRLIS should be cautious of its effects on test ordering and patient venipunctures per day.
引用
收藏
页码:410 / 417
页数:8
相关论文
共 29 条
[1]  
[Anonymous], STAG 1 VS STAG 2 COM
[2]  
[Anonymous], EV COSTS BEN HLTH IN
[3]  
[Anonymous], CRIT REV CLIN LAB SC
[4]  
[Anonymous], MED MED EHR INC PROG
[5]  
[Anonymous], 2013, LAB INTEROPERABILITY
[6]   Decreased Clinical Laboratory Turnaround Time After Implementation of a Collection Manager System [J].
Behling, Kathryn C. ;
Marrone, Dale ;
Hunter, Krystal ;
Bierl, Charlene .
ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2015, 139 (09) :1084-1086
[7]   Launching HITECH [J].
Blumenthal, David .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (05) :382-385
[8]  
Freedman D., 2007, Statistics
[9]   Pathologists' Place in the Electronic Health Record Landscape [J].
Henricks, Walter H. ;
Wilkerson, Myra L. ;
Castellani, William J. ;
Whitsitt, Mark S. ;
Sinard, John H. .
ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2015, 139 (03) :307-310
[10]  
Henricks Walter H, 2011, J Pathol Inform, V2, P7, DOI 10.4103/2153-3539.76733