Portable low-power electronic interface for explosive detection using microcantilevers

被引:24
作者
Garcia-Romeo, D. [1 ]
Pellejero, I. [2 ]
Urbiztondo, M. A. [2 ,3 ]
Sese, J. [2 ]
Pina, M. P. [2 ,4 ]
Martinez, P. A. [1 ]
Calvo, B. [1 ]
Medrano, N. [1 ]
机构
[1] Univ Zaragoza, Fac Ciencias, Aragon Inst Engn Res I3A, Grp Elect Design, E-50009 Zaragoza, Spain
[2] Univ Zaragoza, Nanosci Inst Aragon INA, Zaragoza 50018, Spain
[3] Acad Gen Mil, Ctr Univ Def, Zaragoza 50090, Spain
[4] CIBER BBN, Networking Res Ctr Bioengn Biomat & Nanomed, Zaragoza 50018, Spain
关键词
Microcantilevers; Gas sensing; Zeolites; Nanoporous coating; Explosives; Portable lock-in amplifier; SENSITIVE DETECTION; FREQUENCY; ZEOLITES;
D O I
10.1016/j.snb.2014.04.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microcantilevers have been recently revealed as a highly effective technique for gas detection at trace level when acting as chemical sensors. However, an important milestone still remains to achieve a full-scale development in commercial applications: the cumbersome systems traditionally used to read-out its responses. To accomplish this, a portable low-power electronic interface, based on an analog lock-in amplifier processing square signals, which is fully capable of creating the excitation signal as well as obtaining the response values from resonating microcantilevers functionalized with zeolite based coatings has been herein attempted. The so obtained read-out results are in good agreement with the commercial lock-in amplifier's measurements, demonstrating the accuracy and reliability of the electronic interface. Finally, its performance has been validated for 2-nitrotoluene (o-MNT) detection at ppm V level, as an example of an explosive-related molecule, with BEA zeolite coated microcantilevers. Theoretical limit of detection (LOD) values below 100 ppb have been obtained for Co exchanged BEA modified sensors. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 27 条
[1]  
Aguirre J, 2011, IEEE SENSOR, P1866
[2]  
Aguirre J., 2011, ELECT LETT, V47
[3]   Square-Signal-Based Algorithm for Analog Lock-In Amplifiers [J].
Aguirre, Javier ;
Garcia-Romeo, Daniel ;
Medrano, Nicolas ;
Calvo, Belen ;
Celma, Santiago .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (10) :5590-5598
[4]  
[Anonymous], 1999, 3 SRS
[5]  
[Anonymous], 2004, BAL MOD DEM AD630 DA
[6]   A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout [J].
Battiston, FM ;
Ramseyer, JP ;
Lang, HP ;
Baller, MK ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Güntherodt, HJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) :122-131
[7]   PHASE SENSITIVE DETECTION AS A MEANS TO RECOVER SIGNALS BURIED IN NOISE [J].
BLAIR, DP ;
SYDENHAM, PH .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1975, 8 (08) :621-627
[8]   Cantilever-like micromechanical sensors [J].
Boisen, Anja ;
Dohn, Soren ;
Keller, Stephan Sylvest ;
Schmid, Silvan ;
Tenje, Maria .
REPORTS ON PROGRESS IN PHYSICS, 2011, 74 (03)
[9]   Low-voltage low-power integrated analog lock-in amplifier for gas sensor applications [J].
D'Amico, A. ;
De Marcellis, A. ;
Di Carlo, C. ;
Di Natale, C. ;
Ferri, G. ;
Martinelli, E. ;
Paolesse, R. ;
Stornelli, V. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 144 (02) :400-406
[10]  
Freescale Semiconductor, 2000, SPI BLOCK GUID V03 0