Early Clinical Experience With a Modified Amplatzer Ductal Occluder for Transcatheter Arterial Duct Occlusion in Infants and Small Children

被引:36
作者
Kenny, Damien [1 ]
Morgan, Gareth J. [2 ]
Bentham, James R. [3 ]
Wilson, Neil [4 ]
Martin, Robin [5 ]
Tometzki, Andrew [5 ]
Oslizlok, Paul [6 ]
Walsh, Kevin P. [6 ]
机构
[1] Rush Univ, Med Ctr, Rush Ctr Congenital & Struct Heart Dis, Chicago, IL 60612 USA
[2] Evelina Childrens Hosp, London, England
[3] Leeds Royal Infirm, Leeds, W Yorkshire, England
[4] John Radcliffe Hosp, Oxford OX3 9DU, England
[5] Bristol Congenital Heart Ctr, Bristol, Avon, England
[6] Our Ladys Hosp Sick Children, Dublin, Ireland
关键词
device; nitinol; arterial duct; infants; PERCUTANEOUS CLOSURE; CATHETER CLOSURE; PATENT; DEVICE;
D O I
10.1002/ccd.24522
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesTo describe early clinical experience with the amplatzer ductal occluder II additional sizes (ADO II AS) for percutaneous arterial duct occlusion in infants and small children. MethodsPre-, intra- and postprocedural data analysis of all patients undergoing arterial duct occlusion with the ADO II AS from three tertiary referral centers. Results17 patients (10 female) with a median age of 6 months (range 1.0-48.1 months) and a median weight of 5.7 kg (range 1.7-17.4 kg) underwent attempted transcatheter ductal closure with the ADO II AS. Retrograde arterial approach was used in eight patients with transvenous femoral approach used in nine. The mean minimal ductal diameter was 2.2 0.7 mm with mean ductal length of 6.8 +/- 1.7 mm. Device sizes used were 5/6 (n = 5), 3/4 (n = 4), 4/4 (n = 3), 4/6 (n = 3), and 5/4 (n = 2) with four French delivery sheaths used in all cases. The median fluoroscopy time was 5.7 +/- 1.8 min. Two patients underwent delivery under exclusive echocardiography guidance. Complete ductal occlusion was achieved by the end of the procedure in 13 patients. Device embolization to the left pulmonary artery occurred in one patient with successful surgical removal and ligation of the arterial duct. Three patients required device resizing following deployment of the initial device. Complete ductal occlusion without aortic arch or left pulmonary artery stenosis has been identified in all 16 remaining patients on transthoracic echocardiographic follow-up at median of 4.2 months. ConclusionsThe new amplatzer ductal occluder II AS achieves excellent ductal closure rates through low profile delivery systems in small infants and children with variable ductal anatomy. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:534 / 540
页数:7
相关论文
共 23 条
[1]   The efficacy and safety of the Amplatzer ductal occluder in young children and infants [J].
Al-Ata, J ;
Arfi, AM ;
Hussain, A ;
Kouatli, AA ;
Jalal, MO .
CARDIOLOGY IN THE YOUNG, 2005, 15 (03) :279-285
[2]  
Bass JL, 2011, CATHETER CARDIOVASC
[3]   Echocardiographically Guided Catheter Closure of Arterial Ducts in Small Preterm Infants on the Neonatal Intensive Care Unit [J].
Bentham, Jamie ;
Meur, Saumen ;
Hudsmith, Lucy ;
Archer, Nick ;
Wilson, Neil .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (03) :409-415
[4]   Clinical Evaluation of the New Amplatzer Duct Occluder II for Patent Arterial Duct Occlusion [J].
Bhole, V. ;
Miller, P. ;
Mehta, C. ;
Stumper, O. ;
Reinhardt, Z. ;
De Giovanni, J. V. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (05) :762-769
[5]   The Amplatzer duct occluder: Experience in 209 patients [J].
Bilkis, AA ;
Alwi, M ;
Hasri, S ;
Haifa, AL ;
Geetha, K ;
Rehman, MA ;
Hasanah, I .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) :258-261
[6]   Aortic obstruction caused by device occlusion of patent arterial duct [J].
Duke, C ;
Chan, KC .
HEART, 1999, 82 (01) :109-111
[7]   Challenges encountered during closure of patent ductus arteriosus [J].
Ewert, P .
PEDIATRIC CARDIOLOGY, 2005, 26 (03) :224-229
[8]   Early Clinical Experience With the New Amplatzer Ductal Occluder II for Closure of the Persistent Arterial Duct [J].
Forsey, Jonathan ;
Kenny, Damien ;
Morgan, Gareth ;
Hayes, Alison ;
Turner, Mark ;
Tometzki, Andrew ;
Martin, Robin .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (04) :615-623
[9]   RESULTS OF ANTEROGRADE TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS USING SINGLE OR MULTIPLE GIANTURCO COILS [J].
HIJAZI, ZM ;
GEGGEL, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (09) :925-929
[10]   Transcatheter occlusion of patent ductus arteriosus using a new angled Amplatzer duct occluder: Initial clinical experience [J].
Masura, J ;
Gavora, P ;
Podnar, T .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) :261-267