Power system inertia estimation: Utilization of frequency and voltage response after a disturbance

被引:86
作者
Zografos, Dimitrios [1 ]
Ghandhari, Mehrdad [1 ]
Eriksson, Robert [2 ]
机构
[1] KTH Royal Inst Technol, Dept Elect Power Syst, Tekninkringen 33, S-10044 Stockholm, Sweden
[2] Svenska Kraftnat, Market & Syst Dev, Sturegatan 1, S-17224 Sundbyberg, Sweden
关键词
Frequency response; Power system dynamics; Power system inertia; Renewable energy sources; Voltage response; GENERATION; STABILITY;
D O I
10.1016/j.epsr.2018.04.008
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power system inertia is gradually being reduced due to the ongoing replacement of conventional synchronous power plants by intermittent generation. This affects the frequency response of the system and necessitates the estimation of power system inertia, so that sufficient power reserves are retained. This paper contributes with a novel disturbance-based inertia estimation method, that simultaneously estimates the power change after a disturbance. The proposed method accommodates the frequency and voltage dynamics, which significantly affect the system's power change, and hence the inertia estimation. Two separate approaches - that are also capable of standing alone - are combined, in order to accommodate the dynamics. An extended version of the Nordic32 test system is used for the application of the method, where several case studies and a comparison are investigated, so as to examine the method's accuracy and robustness. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:52 / 60
页数:9
相关论文
共 26 条
[1]  
[Anonymous], 2016, Challenges and Opportunities of Teleworking for Workers and Employers in the ICTS and Financial Services Sectors
[2]  
Ashton P. M., 2013, POW EN SOC GEN M VAN
[3]   Effects of machine inertia constants on system transient stability [J].
Bignell, W ;
Saffron, H ;
Nguyen, TT ;
Humpage, WD .
ELECTRIC POWER SYSTEMS RESEARCH, 1999, 51 (03) :153-165
[4]   Non-synchronous generation impact on power systems coherency [J].
Chamorro, Harold R. ;
Ordonez, Camilo A. ;
Peng, Jimmy C. ;
Ghandhari, Mehrdad .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (10) :2443-2453
[5]   Estimation of WECC system inertia using observed frequency transients [J].
Chassin, DP ;
Huang, Z ;
Donnelly, MK ;
Hassler, C ;
Ramirez, E ;
Ray, C .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (02) :1190-1192
[6]   A Simplified Model for Predicting Primary Control Inadequacy for Nonresponsive Wind Power [J].
Chavez, Hector ;
Hezamsadeh, Mohammad Reza ;
Carlsson, Fredrik .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2016, 7 (01) :271-278
[7]   Regulation Adequacy Analysis Under High Wind Penetration Scenarios in ERCOT Nodal [J].
Chavez, Hector ;
Baldick, Ross ;
Sharma, Sandip .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2012, 3 (04) :743-750
[8]   On the stability of power systems containing doubly fed induction generator-based generation [J].
Elkington, Katherine ;
Enazkins, Valerijs ;
Ghandhari, Mehrdad .
ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (09) :1477-1484
[9]  
Fini M. Hajiakbari, 2018, ELECT POWER SYST RES, V154
[10]  
IEEE Task Force on Load Representation for Dynamic Performance, IEEE T POWER SYST, V8