Evaluation of UV-C Radiation Efficiency in the Decontamination of Inanimate Surfaces and Personal Protective Equipment Contaminated with Phage φ6

被引:10
作者
Bartolomeu, Maria
Braz, Marcia
Costa, Pedro
Duarte, Joao
Pereira, Carla [1 ]
Almeida, Adelaide [1 ]
机构
[1] Univ Aveiro, Dept Biol, Campus Univ Santiago, P-3810193 Aveiro, Portugal
关键词
SARS-CoV-2; surrogate; phage phi 6; UV-C light; disinfection; surfaces; personal protective equipment; ENVELOPED VIRUS; INACTIVATION; PERSISTENCE; CORONAVIRUSES; DISINFECTION; IRRADIATION; BACTERIOPHAGES; TRANSMISSION; MECHANISMS; SARS;
D O I
10.3390/microorganisms10030593
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
To help halt the global spread of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), appropriate disinfection techniques are required. Over the last years, the interest in Ultraviolet-C (UV-C) radiation as a method to disinfect inanimate surfaces and personal protective equipment (PPE) has increased, mainly to efficiently disinfect and prevent SARS-CoV-2 from spreading and allow for the safe reuse of said equipment. The bacteriophage phi 6 (or simply phage phi 6) is an RNA virus with a phospholipid envelope and is commonly used in environmental studies as a surrogate for human RNA-enveloped viruses, including SARS-CoV-2. The present study investigated the use of two new UV irradiation systems ((2)2.4W and (8)5.5W)) constituted by conventional mercury UV-C lamps with a strong emission peak at similar to 254 nm to potentially inactivate phage phi 6 on different surfaces (glass, plastic, stainless steel, and wood) and personal protective equipment, PPE, (surgical and filtering facepiece 2, FFP2, masks, a clear acetate visor, and disposable protective clothing). The results showed that both UV-C systems were effective in inactivating phage phi 6, but the UV-C sterilizing chamber (8)5.5W had the best disinfection performance on the tested surfaces. The inactivation effectiveness is material-dependent on all surfaces, reaching the detection limit of the method at different times (between 60 and 240 s of irradiation). The glass surface needed less time to reduce the virus (30 s) when compared with plastic, stainless, and wood surfaces (60 s). The virus inactivation was more effective in the disposable surgical and FFP2 masks (60 and 120 s, respectively) than in the disposable vest and clear acetate visor (240 s). Overall, this study suggests that UV-C lamps with peak emission at similar to 254 nm could provide rapid, efficient, and sustainable sanitization procedures to different materials and surfaces. However, dosage and irradiation time are important parameters to be considered during their implementation as a tool in the fight against human coronaviruses, namely against SARS-CoV-2.
引用
收藏
页数:12
相关论文
共 55 条
[1]  
Adams M.H., 1959, Bacteriophages
[2]   Upper-room ultraviolet air disinfection might help to reduce COVID-19 transmission in buildings: a feasibility study [J].
Beggs, Clive B. ;
Avital, Eldad J. .
PEERJ, 2020, 8
[3]   UV-C irradiation is highly effective in inactivating SARS-CoV-2 replication [J].
Biasin, Mara ;
Bianco, Andrea ;
Pareschi, Giovanni ;
Cavalleri, Adalberto ;
Cavatorta, Claudia ;
Fenizia, Claudio ;
Galli, Paola ;
Lessio, Luigi ;
Lualdi, Manuela ;
Tombetti, Enrico ;
Ambrosi, Alessandro ;
Redaelli, Edoardo Maria Alberto ;
Saulle, Irma ;
Trabattoni, Daria ;
Zanutta, Alessio ;
Clerici, Mario .
SCIENTIFIC REPORTS, 2021, 11 (01)
[4]  
Biryukov J, 2020, MSPHERE, V5, DOI 10.1128/mSphere.00441-20
[5]   Understanding ultraviolet light surface decontamination in hospital rooms: A primer [J].
Boyce, John M. ;
Donskey, Curtis J. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2019, 40 (09) :1030-1035
[6]   RNA Phage Biology in a Metagenomic Era [J].
Callanan, Julie ;
Stockdale, Stephen R. ;
Shkoporov, Andrey ;
Draper, Lorraine A. ;
Ross, R. Paul ;
Hill, Colin .
VIRUSES-BASEL, 2018, 10 (07)
[7]   Evaluation of eluents for the recovery of an enveloped virus from hands by whole-hand sampling [J].
Casanova, L. M. ;
Weaver, S. R. .
JOURNAL OF APPLIED MICROBIOLOGY, 2015, 118 (05) :1210-1216
[8]  
Chin AWH, 2020, LANCET MICROBE, V1, pE10, DOI [10.1016/S2666-5247(20)30003-3, 10.1016/S2666-5247(20)30095-1]
[9]   Persistence of SARS-CoV-2 infection on personal protective equipment (PPE) [J].
Cordoba-Lanus, Elizabeth ;
Garcia-Perez, Omar ;
Cazorla-Rivero, Sara ;
Rodriguez-Esparragon, Francisco ;
Pinero, Jose-Enrique ;
Clavo, Bernardino ;
Lorenzo-Morales, Jacob .
BMC INFECTIOUS DISEASES, 2021, 21 (01)
[10]  
Cutler Timothy D., 2011, Animal Health Research Reviews, V12, P15, DOI 10.1017/S1466252311000016