Biomechanical study of mandible bone supporting a four-implant retained bridge Finite element analysis of the influence of bone anisotropy and foodstuff position

被引:88
作者
Bonnet, A. S. [1 ]
Postaire, M. [2 ]
Lipinski, P. [1 ]
机构
[1] ENIM, Lab Mech Biomech Polymers & Struct LaBPS, F-57045 Metz, France
[2] Univ Paris 05, Dept Prosthet Dent, F-92120 Montrouge, France
关键词
Dental implants; Mandible anisotropy; Finite element model; Prosthesis design; HUMAN MASTICATORY SYSTEM; PERI-IMPLANT STRESS; IN-VIVO; FIXED PROSTHESES; STRAIN; FORCES; MODEL; OVERDENTURE; EDENTULISM; BEHAVIOR;
D O I
10.1016/j.medengphy.2009.03.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose The aim of this work was to study the biomechanical behavior of a "All-on-four" implant-supported prosthesis through a finite element analysis using either isotropic or anisotropic properties of bone. The influence of foodstuff position during mastication was also analysed. Materials and methods A three-dimensional finite element model of a mandible with a prosthesis supported by four implants was developed. The geometry of the edentulous mandible and prosthesis was generated from computed tomography. Four MKIII (R) implants (two vertical and two tilted) were modeled. The bone elastic properties used in the anisotropic simulations were orthotropic. The comparison of isotropic and anisotropic models was carried out in the loading condition of mastication with a foodstuff positioned on molar. Three distinct configurations, corresponding to three foodstuff positions, were then studied. MSC/Marc code was used to perform all computations. Results Significant differences in stress, strain, and strain energy densities were found in the comparison of isotropic and orthotropic models. Molar position was revealed to be the most critical one, from a stress and strain level point of view, for implants and framework and consequently for peri-implant bone. It was also observed that implant tilting leads to high stress concentrations in bone for the "All-on-four" concept. Conclusion This study showed that the anisotropic behaviour of bone cannot be neglected in the numerical simulations. The actual design of the prosthesis is not optimal concerning the capacity of all metallic parts to support loads. Finally, it was demonstrated that the tilting of implants induced a high stress level at bone-implant interface. (C) 2009 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:806 / 815
页数:10
相关论文
共 45 条
[1]   Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism [J].
Akça, K ;
Iplikçioglu, H .
JOURNAL OF ORAL REHABILITATION, 2002, 29 (04) :350-356
[2]  
[Anonymous], 1985, TISS INT DENT OSS CL
[3]   ESTIMATION OF PHYSIOLOGIC STRESSES WITH A NATURAL TOOTH CONSIDERING FIBROUS PDL-STRUCTURE [J].
ATMARAM, GH ;
MOHAMMED, H .
JOURNAL OF DENTAL RESEARCH, 1981, 60 (05) :873-877
[4]   Bone reactions to longstanding functional load at implants: an experimental study in dogs [J].
Berglundh, T ;
Abrahamsson, I ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (09) :925-932
[5]   Numerical study of shear deformation in Ti-6Al-4V at medium and high strain rates, critical impact velocity in shear [J].
Bonnet-Lebouvier, AS ;
Klepaczko, JR .
INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2002, 27 (07) :755-769
[6]   3-DIMENSIONAL STRESS-DISTRIBUTION AROUND A DENTAL IMPLANT AT DIFFERENT STAGES OF INTERFACE DEVELOPMENT [J].
BORCHERS, L ;
REICHART, P .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (02) :155-159
[7]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[8]  
Branemark P I, 1999, Clin Implant Dent Relat Res, V1, P2, DOI 10.1111/j.1708-8208.1999.tb00086.x
[9]   10-YEAR SURVIVAL RATES OF FIXED PROSTHESES ON 4 OR 6 IMPLANTS AD-MODUM BRANEMARK IN FULL EDENTULISM [J].
BRANEMARK, PI ;
SVENSSON, B ;
VANSTEENBERGHE, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1995, 6 (04) :227-231
[10]   Biomechanical characterization of osseointegration:: An experimental in vivo investigation in the beagle dog [J].
Brånemark, R ;
Öhrnell, LO ;
Skalak, R ;
Carlsson, L ;
Brånemark, PI .