Simple approach for the fabrication of screen-printed carbon-based electrode for amperometric detection on microchip electrophoresis

被引:27
|
作者
Petroni, Jacqueline Marques [1 ]
Lucca, Bruno Gabriel [2 ]
Ferreira, Valdir Souza [1 ]
机构
[1] Univ Fed Mato Grosso do Sul, Inst Quim, BR-79074460 Campo Grande, MS, Brazil
[2] Univ Fed Espirito Santo, Dept Ciencias Nat, BR-29932540 Sao Mateus, ES, Brazil
关键词
Electrochemical detection; Microfabrication; Microfluidic devices; PDMS microchips; Working electrode; FILM ELECTROCHEMICAL DETECTORS; REDUCED GRAPHENE OXIDE; ON-A-CHIP; CAPILLARY-ELECTROPHORESIS; COMPOSITE ELECTRODE; PALLADIUM DECOUPLER; CHANNEL; DEVICE; NITRITE; ELECTROPHORESIS/ELECTROCHEMISTRY;
D O I
10.1016/j.aca.2016.12.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a simple method for the fabrication of screen-printed based electrodes for amperometric detection on microchip electrophoresis (ME) devices. The procedure developed is quite simple and does not require expensive instrumentation or sophisticated protocols commonly employed on the production of amperometric sensors, such as photolithography or sputtering steps. The electrodes were fabricated through manual deposition of home-made conductive carbon ink over patterned acrylic substrate. Morphological structure and electrochemical behavior of the carbon electrodes were investigated by scanning electron microscopy and cyclic voltammetry. The produced amperometric sensors were coupled to polydimethylsiloxane (PDMS) microchips at end-channel configuration in order to evaluate their analytical performance. For this purpose, electrophoretic experiments were carried out using nitrite and ascorbic acid as model analytes. Separation of these substances was successfully performed within 50s with good resolution (R = 1.2) and sensitivities (713.5 pA/mu M for nitrite and 255.4 pA/ mu M for ascorbate). The reproducibility of the fabrication method was evaluated and revealed good values concerning the peak currents obtained (8.7% for nitrite and 9.3% for ascorbate). The electrodes obtained through this method exhibited satisfactory lifetime (ca. 400 runs) over low fabrication cost (less than $1 per piece). The feasibility of the proposed device for real analysis was demonstrated through the determination of nitrite concentration levels in drinking water samples. Based on the results achieved, the approach proposed here shows itself as an interesting alternative for simple fabrication of carbon-based electrodes. Furthermore, the devices indicate great promise for other kind of analytical applications involving ME devices. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:88 / 96
页数:9
相关论文
共 50 条
  • [31] Modified Screen-Printed Microchip for Potentiometric Detection of Terbinafine Drugs
    El-Beshlawy, Menna
    Arida, Hassan
    JOURNAL OF CHEMISTRY, 2022, 2022
  • [32] Indirect Determination of Alkaline Phosphatase Based on the Amperometric Detection of Indigo Carmine at a Screen-Printed Electrode in a Flow System
    María Díaz-González
    César Fernández-Sánchez
    Agustín Costa-García
    Analytical Sciences, 2002, 18 : 1209 - 1213
  • [33] Flow injection amperometric determination of procaine in pharmaceutical formulation using a screen-printed carbon electrode
    Bergamini, Marcio F.
    Santos, Andre L.
    Stradiotto, Nelson R.
    Zanoni, Maria Valnice B.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (01) : 315 - 319
  • [34] A Disposable, Screen-Printed Electrode for the Amperometric Determination of Azide Based on the Immobilization with Catalase or Tyrosinase
    Yue Cui
    John P. Barford
    Reinhard Renneberg
    Analytical Sciences, 2006, 22 : 1279 - 1281
  • [35] Disposable screen-printed carbon-based electrodes in amperometric detection for simultaneous determination of parabens in complex-matrix personal care products by HPLC
    Lucas-Sanchez, Sergio
    Abad-Gil, Lucia
    Isabel-Cabrera, Carmen
    Jesus Gismera, M.
    Teresa Sevilla, M.
    Procopio, Jesus R.
    TALANTA, 2022, 245
  • [36] Indirect determination of alkaline phosphatase based on the amperometric detection of indigo carmine at a screen-printed electrode in a flow system
    Díaz-González, M
    Fernández-Sánchez, C
    Costa-García, A
    ANALYTICAL SCIENCES, 2002, 18 (11) : 1209 - 1213
  • [37] A disposable, screen-printed electrode for the amperometric determination of azide based on the immobilization with catalase or tyrosinase
    Cui, Yue
    Barford, John P.
    Renneberg, Reinhard
    ANALYTICAL SCIENCES, 2006, 22 (10) : 1279 - 1281
  • [38] An amperometric bacterial biosensor based on gold screen-printed electrodes for the detection of benzene
    Lanyon, Yvonne H.
    Tothill, Ibtisam E.
    Mascini, Marco
    ANALYTICAL LETTERS, 2006, 39 (08) : 1669 - 1681
  • [39] Physical characterizations of a screen-printed electrode for use in an amperometric biosensor system
    Grennan, K
    Killard, AJ
    Smyth, MR
    ELECTROANALYSIS, 2001, 13 (8-9) : 745 - 750
  • [40] Amperometric determination of tyrosinase catecholase activity using a screen-printed electrode
    Cui, Yue
    Barford, John P.
    Renneberg, Reinhard