Simple approach for the fabrication of screen-printed carbon-based electrode for amperometric detection on microchip electrophoresis

被引:27
|
作者
Petroni, Jacqueline Marques [1 ]
Lucca, Bruno Gabriel [2 ]
Ferreira, Valdir Souza [1 ]
机构
[1] Univ Fed Mato Grosso do Sul, Inst Quim, BR-79074460 Campo Grande, MS, Brazil
[2] Univ Fed Espirito Santo, Dept Ciencias Nat, BR-29932540 Sao Mateus, ES, Brazil
关键词
Electrochemical detection; Microfabrication; Microfluidic devices; PDMS microchips; Working electrode; FILM ELECTROCHEMICAL DETECTORS; REDUCED GRAPHENE OXIDE; ON-A-CHIP; CAPILLARY-ELECTROPHORESIS; COMPOSITE ELECTRODE; PALLADIUM DECOUPLER; CHANNEL; DEVICE; NITRITE; ELECTROPHORESIS/ELECTROCHEMISTRY;
D O I
10.1016/j.aca.2016.12.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a simple method for the fabrication of screen-printed based electrodes for amperometric detection on microchip electrophoresis (ME) devices. The procedure developed is quite simple and does not require expensive instrumentation or sophisticated protocols commonly employed on the production of amperometric sensors, such as photolithography or sputtering steps. The electrodes were fabricated through manual deposition of home-made conductive carbon ink over patterned acrylic substrate. Morphological structure and electrochemical behavior of the carbon electrodes were investigated by scanning electron microscopy and cyclic voltammetry. The produced amperometric sensors were coupled to polydimethylsiloxane (PDMS) microchips at end-channel configuration in order to evaluate their analytical performance. For this purpose, electrophoretic experiments were carried out using nitrite and ascorbic acid as model analytes. Separation of these substances was successfully performed within 50s with good resolution (R = 1.2) and sensitivities (713.5 pA/mu M for nitrite and 255.4 pA/ mu M for ascorbate). The reproducibility of the fabrication method was evaluated and revealed good values concerning the peak currents obtained (8.7% for nitrite and 9.3% for ascorbate). The electrodes obtained through this method exhibited satisfactory lifetime (ca. 400 runs) over low fabrication cost (less than $1 per piece). The feasibility of the proposed device for real analysis was demonstrated through the determination of nitrite concentration levels in drinking water samples. Based on the results achieved, the approach proposed here shows itself as an interesting alternative for simple fabrication of carbon-based electrodes. Furthermore, the devices indicate great promise for other kind of analytical applications involving ME devices. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:88 / 96
页数:9
相关论文
共 50 条
  • [21] Fabrication and evaluation of a carbon-based dual-electrode detector for poly(dimethylsiloxane) electrophoresis chips
    Gawron, AJ
    Martin, RS
    Lunte, SM
    ELECTROPHORESIS, 2001, 22 (02) : 242 - 248
  • [22] Flexible Screen-Printed Amperometric Sensors Functionalized With Spray-Coated Carbon Nanotubes and Electrodeposited Cu Nanoclusters for Nitrate Detection
    Inam, A. K. M. Sarwar
    Angeli, Martina Aurora Costa
    Shkodra, Bajramshahe
    Douaki, Ali
    Avancini, Enrico
    Magagnin, Luca
    Petti, Luisa
    Lugli, Paolo
    IEEE SENSORS JOURNAL, 2023, 23 (20) : 23966 - 23974
  • [23] Mercury (II) sensor based on nanosilver/chitosan modified screen-printed carbon electrode
    Liu, Ke
    Wang, Qihui
    Zhan, Yifang
    Hong, Shaoli
    Peng, Junjun
    Liu, Huihong
    Mahmud, Sakil
    INORGANIC CHEMISTRY COMMUNICATIONS, 2025, 171
  • [24] A simple epoxy resin screen-printed paper-based analytical device for detection of phosphate in soil
    Thongkam, Thinikan
    Hemavibool, Khuanjit
    ANALYTICAL METHODS, 2022, 14 (10) : 1069 - 1076
  • [25] Rapid and Easy Detection of Deoxynivalenol on a Bismuth Oxide Screen-printed Electrode
    Maria-Hormigos, Roberto
    Jesus Gismera, Maria
    Teresa Sevilla, Maria
    Rumbero, Angel
    Procopio, Jesus R.
    ELECTROANALYSIS, 2017, 29 (01) : 60 - 66
  • [26] Using a sensitive screen-printed electrode based on printex L6 and polyaniline activated carbon for piroxicam detection
    Santos, Anderson M.
    Silva, Taynara O.
    Feitosa, Maria H. A.
    Oliveira, Igor G. S.
    Wong, Ademar
    Souto, Robson S.
    Moraes, Fernando C.
    Ruotolo, Luis A. M.
    Barros, Willyam R. P.
    Lanza, Marcos R. V.
    TALANTA, 2025, 285
  • [27] Screen-Printed Carbon Electrodes with Macroporous Copper Film for Enhanced Amperometric Sensing of Saccharides
    Metelka, Radovan
    Vlasakova, Pavlina
    Smarzewska, Sylwia
    Guziejewski, Dariusz
    Vlcek, Milan
    Sys, Milan
    SENSORS, 2022, 22 (09)
  • [28] Fabrication of iron modified screen printed carbon electrode for sensing of amino acids
    Naqvi, Sayed Tayyab Raza
    Rasheed, Tahir
    Ashiq, Muhammad Naeem
    ul Haq, Muhammad Najam
    Majeed, Saadat
    Fatima, Batool
    Nawaz, Rahat
    Hussain, Dilshad
    Shafi, Sameera
    POLYHEDRON, 2020, 180
  • [29] A novel amperometric sensor based on screen-printed electrode modified with multi-walled carbon nanotubes and molecularly imprinted membrane for rapid determination of ractopamine in pig urine
    Zhang, Hongcai
    Liu, Guoyan
    Chai, Chunyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 : 103 - 110
  • [30] A MWCNTs-COOH/PSS nanocomposite–modified screen-printed electrode for the determination of synthetic phenolic antioxidants by HPLC with amperometric detection
    Lucía Abad-Gil
    Mayte García-Ríos
    Carmen Isabel-Cabrera
    M. Jesús Gismera
    M. Teresa Sevilla
    Jesús R. Procopio
    Microchimica Acta, 2022, 189