Effect of temperature on the cyclic fatigue resistance of thermally treated reciprocating instruments

被引:43
作者
Klymus, Michel Espinosa [1 ]
Alcalde, Murilo Priori [1 ]
Vivan, Rodrigo Ricci [1 ]
Reis So, Marcus Vinicius [2 ]
de Vasconselos, Bruno Carvalho [3 ]
Hungaro Duarte, Marco Antonio [1 ]
机构
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Operat Dent Endodont & Dent Mat, Al Octavio Pinheiro Brisolla 9-75, BR-17012901 Bauru, SP, Brazil
[2] Univ Fed Rio Grande do Sul, Dept Conservat Dent, Porto Alegre, RS, Brazil
[3] Univ Fed Ceara, Dept Endodont, Sobral, CE, Brazil
基金
巴西圣保罗研究基金会;
关键词
Cyclic fatigue; Nickel titanium; Reciprocating systems; Body temperature; MECHANICAL-PROPERTIES; WAVEONE GOLD; THERMOMECHANICAL TREATMENT; TORSIONAL RESISTANCE; BLUE; FILES; WIRE; LIFE;
D O I
10.1007/s00784-018-2718-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesThe aim of this study was to evaluate the impact of body temperature on the cyclic fatigue resistance of different NiTi alloys used for the manufacturing of Reciproc Blue R25 (RB 25.08; VDW, Munich, Germany), X1 Blue File 25 (X1 25.06; MK Life Medical and Dental Products, Porto Alegre, Brazil) and WaveOne Gold Primary (WOG 25.07; Dentsply Maillefer, Ballaigues, Switzerland).Materials and methodsSixty instruments of the RB 25.08, X1 25.06 and WOG 25.07 systems were used (n=20). Cyclic fatigue tests were performed at room temperature (20 degrees 1 degrees C) and at body temperature (37 degrees 1 degrees C). The instruments were reciprocated until fracture occurred in an artificial stainless steel canal with a 60 degrees angle and a 5-mm radius of curvature. The time to fracture (TTF) was recorded. Also, the number of cycles to fracture (NCF) was calculated. Data were analysed using one-way ANOVA and Tukey's tests for inter-group comparison at both temperatures and for the reduction of cyclic fatigue at body temperature. For intra-group comparison at the different temperatures, the unpaired t test was used.ResultsThe cyclic fatigue test at 20 degrees C showed that RB 25.08 and X1 25.06 presented significantly higher TTF and NCF than WOG 25.07 (P<0.05). At 37 degrees C, all groups presented significant reduction of TTF and NCF (P<0.05). RB 25.08 presented significant higher TTF than WOG 25.07 (P<0.05). Regarding the NCF, there was no significant difference among the groups (P>0.05). The WOG 25.07 presented the lowest percentage reduction of cyclic fatigue (P<0.05).Conclusion The body temperature treatment caused a marked reduction of the cyclic fatigue resistance for all reciprocating instruments tested. The RB 25.08 and X1 25.06 systems presented similar results at both temperatures tested. However, WOG 25.07 presented the lowest percentage reduction in fatigue resistance at body temperature.Clinical relevance The cyclic fatigue resistance of NiTi reciprocating instruments has been evaluated at room temperature. However, the fatigue resistance significantly decreases upon exposure to body temperature, which could affect the mechanical behaviour of the NiTi instruments during root canal preparation.
引用
收藏
页码:3047 / 3052
页数:6
相关论文
共 50 条
[41]   Cyclic Fatigue Resistance of Multiused Reciproc Blue Instruments during Retreatment Procedure [J].
Serefoglu, Burcu ;
Kurt, Seniha Micoogullan ;
Kaval, Mehmet Emin ;
Guneri, Pelin ;
Demirci, Gozde Kandemir ;
Caliskan, Mehmet Kemal .
JOURNAL OF ENDODONTICS, 2020, 46 (02) :277-282
[42]   Cyclic and Torsional Fatigue Resistance of XP-endo Shaper and TRUShape Instruments [J].
Nogueira Leal Silva, Emmanuel Joao ;
Leal Vieira, Victor Talarico ;
Belladonna, Felipe Goncalves ;
Zuolo, Arthur de Siqueira ;
Antunes, Henrique dos Santos ;
Cavalcante, Daniele Moreira ;
Elias, Carlos Nelson ;
De-Deus, Gustavo .
JOURNAL OF ENDODONTICS, 2018, 44 (01) :168-172
[43]   Effect of Temperatures on Cyclic Fatigue Resistance of 3 Different Ni-Ti Alloy Files [J].
Hiran-us, Sirawut ;
Morakul, Sarita .
INTERNATIONAL DENTAL JOURNAL, 2023, 73 (06) :904-909
[44]   Cyclic Fatigue Resistance of XP-Endo Shaper, K3XF, and ProTaper Gold Nickel-titanium Instruments [J].
Keskin, Cangul ;
Inan, Ugur ;
Gulen, Duygu H. ;
Kalyoncuoglu, Elif .
JOURNAL OF ENDODONTICS, 2018, 44 (07) :1164-1167
[45]   Bending resistance and cyclic fatigue of a new heat-treated reciprocating instrument [J].
Nogueira Leal Silva, Emmanuel Joao ;
Rodrigues, Cristiane ;
Leal Vieira, Victor Talarico ;
Belladonna, Felipe Goncalves ;
De-Deus, Gustavo ;
Lopes, Helio Pereira .
SCANNING, 2016, 38 (06) :837-841
[46]   Cyclic fatigue of Reciproc Blue and Reciproc instruments exposed to intracanal temperature in simulated severe apical curvature [J].
Inan, Ugur ;
Keskin, Cangul ;
Yilmaz, Ozlem Sivas ;
Bas, Gozde .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (05) :2077-2082
[47]   Variable impact by ambient temperature on fatigue resistance of heat-treated nickel titanium instruments [J].
Arias, Ana ;
Hejlawy, Samer ;
Murphy, Sarah ;
de la Macorra, Jose C. ;
Govindjee, Sanjay ;
Peters, Ove A. .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (03) :1101-1108
[48]   A novel model to evaluate the fatigue resistance of NiTi instruments: Rotational and axial movement at body temperature [J].
Baird, Evan ;
Huang, Xiangya ;
Liu, He ;
Hieawy, Ahmed ;
Ruse, N. Dorin ;
Wang, Zhejun ;
Haapasalo, Markus ;
Shen, Ya .
AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 :301-307
[49]   Cyclic and torsional fatigue resistance of a new rotary file on a rotary and reciprocating motion [J].
So, Gabriel Barcelos ;
Siocheta, Giovana ;
Calefi, Pedro ;
Alcalde, Murilo ;
Vivan, Rodrigo Ricci ;
Duarte, Marco Antonio H. ;
So, Marcus Vinicius Reis ;
da Rosa, Ricardo Abreu .
MICROSCOPY RESEARCH AND TECHNIQUE, 2023, 86 (12) :1635-1641
[50]   Cyclic fatigue resistance of rotary NiTi instruments produced with four different manufacturing methods [J].
Keskin, Neslihan B. ;
Inan, Ugur .
MICROSCOPY RESEARCH AND TECHNIQUE, 2019, 82 (10) :1642-1648