Intravascular Mechanical Cavopulmonary Assistance for Patients With Failing Fontan Physiology

被引:32
作者
Bhavsar, Sonya S. [1 ]
Kapadia, Jugal Y. [1 ]
Chopski, Steven G. [1 ]
Throckmorton, Amy L. [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Mech Engn, Richmond, VA 23284 USA
基金
美国国家科学基金会;
关键词
Ventricular assist device(s); Single ventricle physiology; Cavopulmonary assist device; Fontan conversion; Heart pump; Blood pump; Artificial right ventricle; Pediatric circulatory support; Intravascular blood pump; Mechanical cavopulmonary assist; PEDIATRIC CIRCULATORY SUPPORT; FLOW BLOOD PUMP; CURRENT ERA; DEVICE; CENTRIFUGAL; TRANSPLANTATION; PERFORMANCE; CONNECTION; OPERATION; DESIGN;
D O I
10.1111/j.1525-1594.2009.00940.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To provide a viable bridge-to-transplant, bridge-to-recovery, or bridge-to-surgical reconstruction for patients with failing Fontan physiology, we are developing a collapsible, percutaneously inserted, magnetically levitated axial flow blood pump to support the cavopulmonary circulation in adolescent and adult patients. This unique blood pump will augment pressure and thus flow in the inferior vena cava through the lungs and ameliorate the poor hemodynamics associated with the univentricular circulation. Computational fluid dynamics analyses were performed to create the design of the impeller, the protective cage of filaments, and the set of diffuser blades for our axial flow blood pump. These analyses included the generation of pressure-flow characteristics, scalar stress estimations, and blood damage indexes. A quasi-steady analysis of the diffuser rotation was also completed and indicated an optimal diffuser rotational orientation of approximately 12 degrees. The numerical predictions of the pump performance demonstrated a pressure generation of 2-25 mm Hg for 1-7 L/min over 3000-8000 rpm. Scalar stress values were less than 200 Pa, and fluid residence times were found to be within acceptable ranges being less than 0.25 s. The maximum blood damage index was calculated to be 0.068%. These results support the continued design and development of this cavopulmonary assist device, building upon previous numerical work and experimental prototype testing.
引用
收藏
页码:977 / 987
页数:11
相关论文
共 44 条
  • [31] Use of a ventricular assist device as a bridge to transplantation in a patient with single ventricle physiology and total cavopulmonary anastomosis
    Russo, Pierantonio
    Wheeler, Adam
    Russo, Joanne
    Tobias, Joseph D.
    [J]. PEDIATRIC ANESTHESIA, 2008, 18 (04) : 320 - 324
  • [32] Short-term bridge to transplant using the BVS 5000 in a 22-kg child
    Sadeghi, AM
    Marelli, D
    Talamo, M
    Fazio, D
    Laks, H
    [J]. ANNALS OF THORACIC SURGERY, 2000, 70 (06) : 2151 - 2153
  • [33] Cardiac rest and reserve function in patients with Fontan circulation
    Senzaki, Hideaki
    Masutani, Satoshi
    Ishido, Hirotaka
    Taketazu, Mio
    Kobayashi, Toshiki
    Sasaki, Nozomu
    Asano, Haruhiko
    Katogi, Toshiyuki
    Kyo, Shunei
    Yokote, Yuji
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (12) : 2528 - 2535
  • [34] Quantitative evaluation of blood damage in a centrifugal VAD by computational fluid dynamics
    Song, XW
    Throckmorton, AL
    Wood, HG
    Antaki, JF
    Olsen, DB
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (03): : 410 - 418
  • [35] Cardiovascular malformations among preterm infants
    Tanner, K
    Sabrine, N
    Wren, C
    [J]. PEDIATRICS, 2005, 116 (06) : E833 - E838
  • [36] Mechanical axial flow blood pump to support cavopulmonary circulation
    Throckmorton, A. L.
    Kapadia, J.
    Madduri, D.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (11) : 970 - 982
  • [37] Pediatric circulatory support systems
    Throckmorton, AL
    Allaire, PE
    Gutgesell, HP
    Matherne, GP
    Olsen, DB
    Wood, HG
    Allaire, JH
    Patel, SM
    [J]. ASAIO JOURNAL, 2002, 48 (03) : 216 - 221
  • [38] Pediatric circulatory support: Current strategies and future directions. Biventricular and univentricular mechanical assistance
    Throckmorton, Amy L.
    Chopski, Steven G.
    [J]. ASAIO JOURNAL, 2008, 54 (05) : 491 - 497
  • [39] CFD analysis of a mag-lev ventricular assist device for infants and children: Fourth generation design
    Throckmorton, Amy L.
    Untaroiu, Alexandrina
    [J]. ASAIO JOURNAL, 2008, 54 (04) : 423 - 431
  • [40] Design of a Protective Cage for an Intravascular Axial Flow Blood Pump to Mechanically Assist the Failing Fontan
    Throckmorton, Amy L.
    Kishore, Ravi A.
    [J]. ARTIFICIAL ORGANS, 2009, 33 (08) : 611 - 621