Minimum Current Requirements for Epidural Stimulation Test Confirmation of Epidural and Intrathecal Catheter Placement

被引:7
作者
Sutherland, Michael Alan [1 ]
Viscomi, Christopher M. [1 ]
Dominick, Timothy S. [1 ]
Anderson, Emily L. [1 ]
机构
[1] Univ Vermont, Coll Med, Dept Anesthesiol, Burlington, VT 05408 USA
关键词
NERVE-STIMULATION; ANESTHESIA; MULTIPORT;
D O I
10.1097/AAP.0b013e3181bfbe1e
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objectives: The typical blind insertion of a catheter into the epidural space risks catheter misplacement into the intrathecal space. The epidural stimulation test is designed to confirm the correct epidural location of a catheter but may also detect unintended intrathecal catheter placement by evaluating the minimum electrical current required for appropriate motor stimulation. Using this test, we observed the minimum current requirements for appropriate motor stimulation of catheters placed in the epidural and intrathecal spaces. Methods: In this prospective observational study, patients scheduled for epidural catheter placement and intrathecal catheter placement were evaluated by the epidural stimulation test. The epidural space was localized by using a loss-of-resistance technique with normal saline, and the intrathecal space was identified by advancing a Tuohy needle until a continuous flow of clear cerebrospinal fluid was obtained. Afterward, a catheter was placed in the appropriate space, and a nerve stimulator delivered progressively, increasing electrical current until an appropriate muscle contraction was palpated. The minimum milli-amperage required for this muscle contraction was our primary outcome measure. Results: Of 37 catheters intentionally placed in the epidural space, the mean current required to produce an appropriate palpable motor contraction was 7.8 +/- 3.3 mA with a range of 2 to 14 mA. Of the 11 catheters intentionally placed in the intrathecal space, the mean current required to produce an appropriate palpable motor contraction was 13 +/- 0.8 mA with a range of 0.05 to 2.4 mA. Conclusions: We conclude that the epidural stimulation test minimum electrical current requirement seems to be lower for intrathecal compared with epidural catheter placement.
引用
收藏
页码:575 / 577
页数:3
相关论文
共 9 条
[1]   A comparison of multiport and uniport epidural catheters in laboring patients [J].
DAngelo, R ;
Foss, ML ;
Livesay, CH .
ANESTHESIA AND ANALGESIA, 1997, 84 (06) :1276-1279
[2]   A prospective comparative study of two indirect methods for confirming the localization of an epidural catheter for postoperative analgesia [J].
de Medicis, E ;
Tetrault, JP ;
Martin, R ;
Robichaud, R ;
Laroche, L .
ANESTHESIA AND ANALGESIA, 2005, 101 (06) :1830-1833
[3]   Confirmation of direct epidural catheter placement using nerve stimulation in pediatric anesthesia [J].
Goobie, SM ;
Montgomery, CJ ;
Basu, R ;
McFadzean, J ;
O'Connor, GJ ;
Poskitt, K ;
Tsui, BCH .
ANESTHESIA AND ANALGESIA, 2003, 97 (04) :984-988
[4]   ROENTGENOGRAPHIC ANALYSIS OF POSITIONS OF CATHETERS IN EPIDURAL SPACE [J].
MUNEYUKI, M ;
SHIRAI, K ;
INAMOTO, A .
ANESTHESIOLOGY, 1970, 33 (01) :19-&
[5]  
Richardson MG, 1996, REGION ANESTH, V21, P119
[6]   Epidural stimulation test criteria [J].
Tsui, Ban C. H. .
ANESTHESIA AND ANALGESIA, 2006, 103 (03) :775-776
[7]   An in vitro comparison of the electrical conducting properties of multiport versus single-port epidural catheters for the epidural stimulation test [J].
Tsui, BCH ;
Sze, CKC .
ANESTHESIA AND ANALGESIA, 2005, 101 (05) :1528-1530
[8]   Confirmation of epidural catheter placement using nerve stimulation [J].
Tsui, BCH ;
Gupta, S ;
Finucane, B .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (07) :640-644
[9]   Detection of subarachnoid and intravascular epidural catheter placement [J].
Tsui, BCH ;
Gupta, S ;
Finucane, B .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (07) :675-678