Development and validation of a stability indicating RP-HPLC-DAD method for the determination of bromazepam

被引:6
|
作者
Darwish, Hany W. [1 ,2 ]
Ali, Nesma A. [3 ]
Naguib, Ibrahim A. [4 ]
El Ghobashy, Mohamed R. [2 ,5 ]
Al-Hossaini, Abdullah M. [1 ]
Abdelrahman, Maha M. [6 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh, Saudi Arabia
[2] Cairo Univ, Fac Pharm, Analyt Chem Dept, Cairo, Egypt
[3] Justice Minist, Analyt Toxicol Lab, Forens Med Author, Cairo, Egypt
[4] Taif Univ, Coll Pharm, Dept Pharmaceut Chem, At Taif, Saudi Arabia
[5] October 6 Univ, Fac Pharm, Giza, Egypt
[6] Beni Suef Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, Bani Suwayf, Egypt
来源
PLOS ONE | 2021年 / 16卷 / 03期
关键词
D O I
10.1371/journal.pone.0244951
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A reliable, selective and sensitive stability-indicating RP-HPLC assay was established for the quantitation of bromazepam (BMZ) and one of the degradant and stated potential impurities; 2-(2-amino-5-bromobenzoyl) pyridine (ABP). The assay was accomplished on a C-18 column (250 mm x 4.6 mm i.d., 5 mu m particle size), and utilizing methanol-water (70: 30, v/v) as the mobile phase, at a flow rate of 1.0 ml min(-1). HPLC detection of elute was obtained by a photodiode array detector (DAD) which was set at 230 nm. ICH guidelines were adhered for validation of proposed method regarding specificity, sensitivity, precision, linearity, accuracy, system suitability and robustness. Calibration curves of BMZ and ABP were created in the range of 1-16 mu g mL(-1) with mean recovery percentage of 100.02 +/- 1.245 and 99.74 +/- 1.124, and detection limit of 0.20 mu g mL(-1) and 0.24 mu g mL(-1) respectively. BMZ stability was inspected under various ICH forced degradation conditions and it was found to be easily degraded in acidic and alkaline conditions. The results revealed the suitability of the described methodology for the quantitation of the impurity (ABP) in a BMZ pure sample. The determination of BMZ in pharmaceutical dosage forms was conducted with the described method and showed mean percentage recovery of 99.39 +/- 1.401 and 98.72 +/- 1.795 (n = 6), respectively. When comparing the described procedure to a reference HPLC method statistically, no significant differences between the two methods in regard to both accuracy and precision were found.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] DEVELOPMENT AND VALIDATION OF RP-HPLC-DAD METHOD FOR DETERMINATION OF NINE DRUGS AND THEIR ELEVEN METABOLITES IN PLASMA AND URINE: PLASMA SAMPLES MEASUREMENTS
    Baranowska, Irena
    Wilczek, Andrzej
    Michal, Kwiatkowski
    Baranowski, Jacek
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (12) : 1597 - 1615
  • [22] Development and Validation of a Stability Indicating HPLC Method for Determination of Granisetron
    Souri, Effat
    Kargar, Zahra
    Saremi, Shahrooz
    Ravari, Nazanin Shabani
    Alvandifar, Farhad
    Amanlou, Massoud
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2011, 58 (04) : 443 - 449
  • [23] Stability Indicating RP-HPLC-DAD method for simultaneous estimation of tadalafil and macitentan in synthetic mixture for treatment of pulmonary arterial hypertension
    Gol, Dhruvanshi
    Vyas, Amitkumar
    Visana, Nilam
    Patel, Ajay
    Shah, Sunny
    Sheth, Devang
    Dholakia, Sandip
    ANNALES PHARMACEUTIQUES FRANCAISES, 2024, 82 (03): : 464 - 472
  • [24] Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Ezetimibe in Pharmaceutical Dosage Forms
    Nakarani, Mahendra P.
    Patel, Priyal R.
    Patel, Jayavadan K.
    Vaghani, Subhash S.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2011, 30 (05): : 896 - 901
  • [25] Stability indicating RP-HPLC method development and validation for oseltamivir API
    Narasimhan, Balasubramanian
    Abida, Khan
    Srinivas, Kona
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2008, 56 (04) : 413 - 417
  • [26] Development and Validation of a Stability-Indicating RP-HPLC Method for Determination of Atomoxetine Hydrochloride in Tablets
    Patel, Sejal K.
    Patel, Natvarlal J.
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (04) : 1207 - 1214
  • [27] Development and Validation of Stability-Indicating RP-HPLC Method for Determination of Indapamide and Amlodipine Besylate
    Gandhi, Santosh V.
    Karad, Madhuri M.
    Deshpande, Padmanabh B.
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2014, 48 (02) : 48 - 54
  • [28] Development and validation of a stability-indicating RP-HPLC method for the determination of fifteen impurities in rivaroxaban
    Rao, Wanbing
    Li, Lijun
    Zhang, Chenxia
    Zheng, Jinfu
    Fan, Xiaomei
    Luan, Baolei
    Sun, Jiaxiang
    Qiu, Meiyan
    Wu, Shuming
    Li, Yanhua
    Wang, Zhongqing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 228
  • [29] Development and Validation of a Stability-indicating RP-HPLC Method for the Determination of Rivaroxaban in Pharmaceutical Formulations
    Walter, Mauricio E.
    Perobelli, Rafaela F.
    Da Silva, Francielle S.
    Cardoso Junior, Clovis D. A.
    da Silva, Iorhann S.
    Dalmora, Sergio L.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (08): : 1503 - 1510
  • [30] RP-HPLC-DAD Determination of Phenolics in Industrial Apple Pomace
    Rana, Shalika
    Rana, Ajay
    Gulati, Ashu
    Bhushan, Shashi
    FOOD ANALYTICAL METHODS, 2014, 7 (07) : 1424 - 1432