Experimental Investigation of Inductive Sensor Characteristic for Blade Tip Clearance Measurement at High Temperature

被引:11
作者
Liu, Zhenxia [1 ]
Zhao, Ziyu [1 ]
Lyu, Yaguo [1 ]
Zhao, Lingqiang [1 ]
机构
[1] Northwestern Polytech Univ, Sch Power & Energy, Youyi West Rd 127, Xian 710054, Shaanxi, Peoples R China
关键词
inductive sensor; tip clearance; repeatability error; high temperature; calibration;
D O I
10.3390/s19173694
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Turbine tip clearance of aero-engine is important to engine performance. Proper tip clearance can reduce the gas leakage over turbine blade tips and improve the engine efficiency of turbo machinery and reduce the fuel consumption. Therefore, accurate tip clearance measurement is essential. The inductive measurement method is one of the non-contact distance measurement methods, which has the characteristics of high sensitivity, fast response speed, and strong anti-interference ability. Based on the principle of inductive sensor measuring tip clearance, the ambient temperature change may cause the material electromagnetic performance change for the conductivity and permeability varies with temperature. In order to verify the temperature effect on the sensor performance, the repeated calibration experiments were carried out to obtain the sensor repeatability error of 5.4%. Then, the sensor was calibrated in the range of 0 mm-4 mm clearance at temperature from 600 degrees C to 1000 degrees C and obtained the measurement error of 4.6%. Results indicate when the temperature ranged from 600 degrees C to 1000 degrees C, clearance measurement error is smaller than the sensor repeatability error so the temperature effect on the sensor characteristics can be ignored. This conclusion makes the sensor promising for monitoring the blade tip clearances at various temperature environment.
引用
收藏
页数:13
相关论文
共 27 条
[1]  
Andreas K., 2006, P 13 INT S APPL LAS
[2]  
Chana KS, 2016, PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2016, VOL 6
[3]  
Chana K.S., 2013, P ASME TURB EXP SAN
[4]   A high sensitivity inductive sensor for blade tip clearance measurement [J].
Du, Li ;
Zhu, Xiaoliang ;
Zhe, Jiang .
SMART MATERIALS AND STRUCTURES, 2014, 23 (06)
[5]   Design, Fabrication and Testing of a High-Sensitive Fibre Sensor for Tip Clearance Measurements [J].
Durana, Gaizka ;
Amorebieta, Josu ;
Fernandez, Ruben ;
Beloki, Josu ;
Arrospide, Eneko ;
Garcia, Iker ;
Zubia, Joseba .
SENSORS, 2018, 18 (08)
[6]   Tip-Clearance Measurement in the First Stage of the Compressor of an Aircraft Engine [J].
Garcia, Iker ;
Przysowa, Radoslaw ;
Amorebieta, Josu ;
Zubia, Joseba .
SENSORS, 2016, 16 (11)
[7]   Different Configurations of a Reflective Intensity-Modulated Optical Sensor to Avoid Modal Noise in Tip-Clearance Measurements [J].
Garcia, Iker ;
Zubia, Joseba ;
Berganza, Amaia ;
Beloki, Josu ;
Arrue, Jon ;
Asuncion Illarramendi, Maria ;
Mateo, Javier ;
Vazquez, Carmen .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2015, 33 (12) :2663-2669
[8]   An Optical Fiber Bundle Sensor for Tip Clearance and Tip Timing Measurements in a Turbine Rig [J].
Garcia, Iker ;
Beloki, Josu ;
Zubia, Joseba ;
Aldabaldetreku, Gotzon ;
Asuncion Illarramendi, Maria ;
Jimenez, Felipe .
SENSORS, 2013, 13 (06) :7385-7398
[9]   An Architecture for On-Line Measurement of the Tip Clearance and Time of Arrival of a Bladed Disk of an Aircraft Engine [J].
Gil-Garcia, Jose Miguel ;
Solis, Alejandro ;
Aranguren, Gerardo ;
Zubia, Joseba .
SENSORS, 2017, 17 (10)
[10]  
Haase W. C., 2013, AER C 2013 IEEE MARC, P1