Measurement properties of the short version of the Van Lieshout test for arm/hand function of persons with tetraplegia after spinal cord injury

被引:32
作者
Post, M. W. M. [3 ]
Van Lieshout, G.
Seelen, H. A. M.
Snoek, G. J.
IJzerman, M. J.
Pons, C.
机构
[1] Rudolf Magnus Inst Neurosci, NL-3508 AE Utrecht, Netherlands
[2] IRv Inst Rehabil Res, Hoensbroek, Netherlands
[3] Rehabil Ctr Hoogstraat, NL-3508 AE Utrecht, Netherlands
[4] Rehabil Ctr Hoensbroeck, Hoensbroek, Netherlands
[5] Roessingh Res & Dev, Enschede, Netherlands
关键词
spinal cord injuries; tetraplegia; reproducibility of results; validation study; upper extremity;
D O I
10.1038/sj.sc.3101937
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study design: Two validation studies. Objectives: To assess the measurement properties of the short version of the Van Lieshout test (VLT-SV), a new test for arm/hand function of persons with tetraplegia after spinal cord injury (SCI). Setting: Two specialized rehabilitation centres in The Netherlands. Methods: Study 1 (N = 12) -assessment of inter-rater reliability (intraclass correlations (ICC); weighted kappa; Bland-Altman plots). Study 2 (N = 55) - assessment of convergent validity by computing Spearman's correlations with the Grasp-Release test (GRT; criterion standard) and with motor level of injury, ASIA impairment scale, international classification for surgery of the hand, and the self-care and transfer scales of the functional independence measure. All statistics were computed separately for the right- and the left-hand scores. Results: Inter-rater reliability was excellent (ICC 0.98 and 0.99). Agreement was independent of the height of the scores and the limits of agreement were +/- 0.5 points on a 0-5 scale. Convergent validity was very good with a Spearman correlation of 0.87 and 0.90 between the VLT-SV and the GRT and correlations between 0.35 and 0.85 with the other indicators of arm/hand function. Conclusion: The VLT-SV seems a reliable and valid test to assess arm/hand function of persons with tetraplegia after SCI.
引用
收藏
页码:763 / 771
页数:9
相关论文
共 24 条
[1]  
American Spinal Injury Association/International Medical Society of Paraplegia, 2000, INT STAND NEUR FUNCT
[2]  
[Anonymous], 2001, ICF: International Classification of Functioning, Disability and Health: Short Version
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   DEVELOPMENT OF A TETRAPLEGIC HAND ASSESSMENT AND SPLINTING PROTOCOL [J].
CURTIN, M .
PARAPLEGIA, 1994, 32 (03) :159-169
[5]  
Curtin M., 1999, BR J OCC THER, V62, P444
[6]   Motor capacities of upper limbs in tetraplegics: a new scale for the assessment of the results of functional surgery on upper limbs [J].
Fattal, C .
SPINAL CORD, 2004, 42 (02) :80-90
[7]  
Fleiss J. L., 1981, Statistical Methods for Rates and Proportions, V2nd
[8]   THE QUADRIPLEGIA INDEX OF FUNCTION (QIF) - SENSITIVITY AND RELIABILITY DEMONSTRATED IN A STUDY OF 30 QUADRIPLEGIC PATIENTS [J].
GRESHAM, GE ;
LABI, MLC ;
DITTMAR, SS ;
HICKS, JT ;
JOYCE, SZ ;
STEHLIK, MAP .
PARAPLEGIA, 1986, 24 (01) :38-44
[9]   Characteristics of the functional independence measure in traumatic spinal cord injury [J].
Hall, KM ;
Cohen, ME ;
Wright, J ;
Call, M ;
Werner, P .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (11) :1471-1476
[10]  
HAMILTON BB, 1999, SCAND J REHABIL MED, V36, P115