Fabrication and characterization of hydroxyapatite reinforced with 20 vol % Ti particles for use as hard tissue replacement

被引:56
作者
Chu, C [1 ]
Lin, P
Dong, Y
Xue, X
Zhu, J
Yin, Z
机构
[1] SE Univ, Dept Mech Engn, Nanjing 210018, Peoples R China
[2] SE Univ, Zhongda Hosp, Sch Med, Nanjing 210018, Peoples R China
[3] Harbin Inst Technol, Sch Mat Sci & Engn, Harbin 150001, Peoples R China
关键词
D O I
10.1023/A:1019873015772
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hydroxyapatite(HA)-based composite reinforced with 20 vol % titanium (Ti) particles was fabricated by hot pressing based on the studies of the structural stability of HA phase in HA-Ti composite by means of FTIR spectrometry and X-ray diffractometry. The mechanical properties and biological behaviors of the composite were investigated by mechanical and in vivo studies. The existence of Ti metal phase can promote the dehydration and decomposition of HA ceramic phase into the more stable calcium phosphate phases, such as alpha-Ca-3(PO4)(2) (alpha-TCP) and Ca4O(PO4)(2) at high temperatures. Comparing with pure HA ceramic manufactured under the same conditions, HA-20 vol % Ti composite with higher fracture toughness (0.987 MPa m(1/2)), bending strength (78.59 MPa), work of fracture (12.8J/m(2)), porosity (9.8%) and lower elastic modulus (75.91 GPa) is more suitable for use as hard tissue replacement. Crack deflection is the chief toughening mechanism in the composite. Histological evaluation by light microscope shows HA-20 vol % Ti composite implant could be partially integrated with newborn bone tissues after 3 weeks and fully osteointegrated at 12 weeks in vivo. The excellent biological properties of HA-20 vol % Ti composite may be contributed to the coexistence of high porosity and the decomposition products of HA phase in the composite. (C) 2002 Kluwer Academic Publishers.
引用
收藏
页码:985 / 992
页数:8
相关论文
共 43 条
[1]  
[Anonymous], 1993, MICROWAVES THEORY AP
[2]  
Aoki H., 1991, SCI MED APPL HYDROXY
[3]   SYNTHESIS AND PROCESSING OF HYDROXYAPATITE CERAMIC TAPES WITH CONTROLLED POROSITY [J].
ARITA, IH ;
CASTANO, VM ;
WILKINSON, DS .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1995, 6 (01) :19-23
[4]   TOXICITY OF SILICON-CARBIDE WHISKERS [J].
BIRCHALL, JD ;
STANLEY, DR ;
MOCKFORD, MJ ;
PIGOTT, GH ;
PINTO, PJ .
JOURNAL OF MATERIALS SCIENCE LETTERS, 1988, 7 (04) :350-352
[5]  
BONFIELD W, 1988, BIOCERAMICS MATERIAL, V523, P173
[6]   DENSIFICATION AND STRENGTHENING OF SILVER-REINFORCED HYDROXYAPATITE-MATRIX COMPOSITE PREPARED BY SINTERING [J].
CHAKI, TK ;
WANG, PE .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (08) :533-542
[7]  
CHU CL, 2000, THESIS HARBIN I TECH
[8]  
CHU CL, 1999, FUNCTIONAL MAT, V30, P606
[9]  
DEWITH G, 1981, J MATER SCI, V16, P1592, DOI 10.1007/BF02396876
[10]   METAL FIBER REINFORCED HYDROXY-APATITE CERAMICS [J].
DEWITH, G ;
CORBIJN, AJ .
JOURNAL OF MATERIALS SCIENCE, 1989, 24 (09) :3411-3415