Simultaneous and sensitive determination of multiplex chemical residues based on multicolor quantum dot probes

被引:97
作者
Peng, Chifang [1 ]
Li, Zhuokun [1 ]
Zhu, Yinyue [1 ]
Chen, Wei [1 ]
Yuan, Yuan [1 ]
Liu, Liqiang [1 ]
Li, Qiusheng [1 ]
Xu, Dinghua [1 ]
Qiao, Ruirui [2 ]
Wang, Libing [1 ]
Zhu, Shuifang [1 ]
Jin, Zhengyu [1 ]
Xu, Chuanlai [1 ]
机构
[1] Jiangnan Univ, Sch Food Sci & Technol, Wuxi 214122, Jiangsu Prov, Peoples R China
[2] CAS, Inst Chem, Beijing 10008, Peoples R China
基金
中国国家自然科学基金;
关键词
Simultaneous; Sensitive; Determination; Multiplex chemical residues; Multicolor; Quantum dot; Probes; MASS-SPECTROMETRY; IN-VIVO; GAS-CHROMATOGRAPHY; NANOCRYSTALS; URINE; BENZODIAZEPINES; PROTEIN;
D O I
10.1016/j.bios.2009.05.031
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Biotinylated denatured bovine serum albumin (Bt-dBSA)-coated cadmium telluride (CdTe) quantum dot (QD) conjugates were prepared and used to develop the multiplexed fluoroimmunoassay for the simultaneous determination of five chemical residues. An immune complex was formed using avidin as the bridge to link the Bt-dBSA-QDs with the antibodies. Primarily, individual quantitative determinations of five representative chemical residues were carried out based on the different emission properties of the QDs. Five antibodies were then conjugated with the corresponding QDs to establish the indirect competition fluorescent-linked immunosorbent assay (ic-FLISA) for the simultaneous detection of five chemicals in one well of a microplate. The linear range for dexamethason (DEX) was from 0.33 mu g/kg to 10 mu g/kg, 0.28 mu g/kg to 10 mu g/kg for gentamicin (GM), 0.16 mu g/kg to 25 mu g/kg for clonazepam (UP), 0.17 mu g/kg to 10 mu g/kg for medroxyprogesterone acetate (MPA) and 0.32 mu g/kg to 25 mu g/kg for ceftiofur (CEF), respectively. The limit of detection (LOD) for the simultaneous determination of DEX, GM, CZP, MPA and CEF were as low as 0.13 mu g/kg, 0.16 mu g/kg, 0.07 mu g/kg, 0.06 mu g/kg and 0.14 mu g/kg, respectively. This detection method was used to analyze samples of pork muscle and the recoveries ranged from 61.3% to 80.3% for DEX and from 74.0% to 87.2% for MPA. Further more, good correlation between the novel ic-FLISA and traditional ELISA was demonstrated during the determination of DEX and MPA residues in real samples. The QD-based protocol described here is less time consuming than the classical method and it may be sufficiently flexible to be used in other systems for the simultaneous multicolor detection of the drugs. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3657 / 3662
页数:6
相关论文
共 40 条
[1]   Semiconductor clusters, nanocrystals, and quantum dots [J].
Alivisatos, AP .
SCIENCE, 1996, 271 (5251) :933-937
[2]  
AMBER DW, 2006, ANAL CHEM, V78, P4450
[3]  
ATTOUSSI H, 2000, J AM CHEM SOC, V122, P12142
[4]  
BRIAN ML, 2003, ANAL CHEM, V75, P4043
[5]   Semiconductor nanocrystals as fluorescent biological labels [J].
Bruchez, M ;
Moronne, M ;
Gin, P ;
Weiss, S ;
Alivisatos, AP .
SCIENCE, 1998, 281 (5385) :2013-2016
[6]   Quantum dot bioconjugates for ultrasensitive nonisotopic detection [J].
Chan, WCW ;
Nie, SM .
SCIENCE, 1998, 281 (5385) :2016-2018
[7]   Ultrasensitive immunoassay of 7-aminoclonazepam in human urine based on CdTe nanoparticle bioconjugations by fabricated microfluidic chip [J].
Chen, Wei ;
Peng, Chifang ;
Jin, Zhengyue ;
Qiao, Ruirui ;
Wang, Wuyang ;
Zhu, Shuifang ;
Wang, Libing ;
Jing, Qinhui ;
Xu, Chuanlai .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) :2051-2056
[8]   Recent developments in the use and abuse of growth promoters [J].
Courtheyn, D ;
Le Bizec, B ;
Brambilla, G ;
De Brabander, HF ;
Cobbaert, E ;
de Wiele, AV ;
Vercammen, J ;
De Wasch, K .
ANALYTICA CHIMICA ACTA, 2002, 473 (1-2) :71-82
[9]   In vivo imaging of quantum dots encapsulated in phospholipid micelles [J].
Dubertret, B ;
Skourides, P ;
Norris, DJ ;
Noireaux, V ;
Brivanlou, AH ;
Libchaber, A .
SCIENCE, 2002, 298 (5599) :1759-1762
[10]  
ELLEN RG, 2004, ANAL CHEM, V76, P684