Long-duration acceptance test for an operating integrated solar combined cycle solar field

被引:1
作者
E.L. Weteedy, Ahmed [1 ]
Elmaihy, Ali [1 ]
机构
[1] Mil Tech Coll, Mech Power & Energy, Cairo, Egypt
关键词
combined cycle power stations; solar absorber-convertors; solar power stations; thermal power stations; power consumption; meteorological data; operational data; thermal energy output; auxiliary energy consumption; parabolic trough solar field; predicted performance metrics; specified test conditions; testing procedures; model predictions; acceptance test guidelines; concentrating solar power production; concentrated solar power plants; long-duration performance acceptance test; integrated solar combined cycle solar field; international performance testing codes; performance testing validation; American Society of Mechanical Engineers; Kurymat; Egypt; PT solar field; PARABOLIC-TROUGH COLLECTOR; PERFORMANCE ANALYSIS; VALIDATION; SYSTEMS;
D O I
10.1049/iet-rpg.2019.0471
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The commercial concern in performance testing validation increases due to the enlargement of the concentrating solar power production. Unfortunately, no common approach or test code exists worldwide for this principle. The American Society of Mechanical Engineers and others are currently developing standards for concentrated solar power plants that have not come to fruition yet. In this study, the long-duration performance acceptance test was carried out for the integrated solar combined cycle solar field of Kurymat, Egypt. The work included measurement of meteorological and operational data, calculation of the thermal energy output, and auxiliary energy consumption of parabolic trough (PT) solar field during consecutive 14 days with 88 total operating hours, to verify the predicted performance metrics under specified test conditions. The testing procedures, model formulation and measured data uncertainties of the solar field were conducted. The model predictions and measured results with their uncertainties were compared. The study can be potentially advantageous for the current developing international performance testing codes to validate the proposed acceptance test guidelines of PT solar field.
引用
收藏
页码:2993 / 3001
页数:9
相关论文
共 35 条
[1]  
[Anonymous], 2012, THESIS
[2]  
ASME PTC 19.1, 2006, 191 ASME PTC
[3]  
ASTM E2848-11, 2011, E284811 ASTM INT, DOI [10.1520/E2848-11, DOI 10.1520/E2848-11]
[4]  
ASTM E905-87, 2013, E90587 ASTM INT, V2013, DOI 10.1520/E0905-87R13
[5]  
Basson H., 2015, THESIS
[6]   A novel parabolic trough solar collector model - Validation with experimental data and comparison to Engineering Equation Solver (EES) [J].
Behar, Omar ;
Khellaf, Abdallah ;
Mohammedi, Kamal .
ENERGY CONVERSION AND MANAGEMENT, 2015, 106 :268-281
[7]  
Brakmann G., 2009, P SOLARPACES S BERL
[8]   Numerical Simulation and Experimental Validation of Integrated Solar Combined Power Plant [J].
Dayem, A. M. Abdel ;
Metwally, M. Nabil ;
Alghamdi, A. S. ;
Marzouk, E. M. .
TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES14 - EUMISD), 2014, 50 :290-305
[9]  
Dierauf T., 2013, WEATHER PERFORMANCE
[10]  
Dows R. N., 1995, 95309100001 PAC GAS